Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The aim of the present study was to compare hemoglobin (Hb) levels determined by point of care testing HemaCue and arterial blood gas analyzer with an automated hematology analyzer in critically ill geriatric patients.Forty geriatric patients requiring intensive care treatment were included in the study. Arterial blood sample was analyzed using HemaCue (HbHemaCueArterial), blood gas analyzer (Techno Medica, Gastat1800 series) (HbBGA) and an automated hematology analyzer (Cell Dyne 3700 System, Abbot Laboratories)(HbLab) as a reference method. Capillary blood measurements were performed (HbHemaCueCapillary) by HemaCue at bedside.
The aim of the present study was to compare hemoglobin (Hb) levels determined by point of care testing HemaCue and arterial blood gas analyzer with an automated hematology analyzer in critically ill geriatric patients.Forty geriatric patients requiring intensive care treatment were included in the study. Arterial blood sample was analyzed using HemaCue (HbHemaCueArterial), blood gas analyzer (Techno Medica, Gastat1800 series) (HbBGA) and an automated hematology analyzer (Cell Dyne 3700 System, Abbot Laboratories)(HbLab) as a reference method. Capillary blood measurements were performed (HbHemaCueCapillary) by HemaCue at bedside. Bland Altman Analysis was applied to the results .
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| hb analysis with Hemacue | Other | Hb analysis with Hemacue and with arterial blood gas analyser in geriatric ill patients requiring intensive care |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| HemaCue | Device | comparing hemoglobin (Hb) levels determined by point of care testing HemaCue and arterial blood gas analyzer with an automated hematology analyzer in critically ill geriatric patients. |
| Measure | Description | Time Frame |
|---|---|---|
| hemoglobin levels | comparing hemoglobin (Hb) levels determined by point of care testing HemaCue and arterial blood gas analyzer with an automated hematology analyzer in critically ill geriatric patients. | 1 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
-
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| MEHTAP HONCA, Ass. Prof | Kecioren training and research Hospital , Department of Anesthesiology and Reanimation | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mehtap Honca | Ankara | Kecioren | 06010 | Turkey (Türkiye) |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|