The purpose of this study is to compare the Ziemer Ophthalmic Systems AG GALILEI G6 Lens Professional to the Oculus Pentacam® AXL for taking images and measurements of the anterior segment of the eye, including the cornea, pupil, anterior chamber and lens, to assist in determining the power of the intraocular lens for implantation.
A corneal topographer/biometer named GALILEI G6 Lens Professional was developed by Ziemer Ophthalmic Systems AG for the measurement of anterior segment geometry and axial intraocular distances. The measurement principle of the corneal topographer corresponds to that of the commercially available Galilei G4 Dual Scheimpflug Analyzer, whereas the measurement principle of the biometer is based on low coherence interferometry/reflectometry, which has been widely used and applied clinically by a number of predicate devices.
One complete measurement consists of a corneal topography/ tomography scan followed by three consecutive, axial biometry scans of the anterior segment (cornea and crystalline lens) and three consecutive, axial biometry scans of the retina. The measurement process is continuous but divided into three alignment-click-steps.
Such measurements can be applied to given Intra Ocular Lens (IOL) types and IOL equations, to permit the calculation of recommended IOLs to be implanted during cataract surgery in order to achieve the desired vision correction.
The primary objectives of this clinical study are to: 1) evaluate the inter-device repeatability, inter-operator repeatability and reproducibility of the GALILEI G6 Lens Professional in repeated measurements of anterior segment geometry and axial intraocular distances and, 2) demonstrate substantial equivalence through examining agreement of the GALILEI measurements to those of the predicate device, the Pentacam® AXL.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| GALILEI G6 Lens Professional | Experimental | The GALILEI G6 Lens Professional will measure anterior segment geometry and axial intra-ocular distances of the eye. |
|
| Oculus Pentacam AXL | Active Comparator | The Oculus Pentacam AXL will measure anterior segment geometry and axial intra-ocular distances of the eye. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| GALILEI G6 Lens Professional | Device | Eight measurements of the eye using the GALILEI G6 Lens Professional will be taken using two different devices and 2 different operators |
|
| Measure | Description | Time Frame |
|---|---|---|
| Axial Length (AL) Measurement in millimeters (mm) | Repeatability and reproducability across and between evaluations | One day |
| Central Corneal Thickness (CCT) Measurement in micrometers (µm) | Repeatability and reproducability across and between evaluations | One day |
| Radius Flat Meridian (R flat) Measurement in millimeters (mm) | Repeatability and reproducability across and between evaluations | One day |
| Radius Steep Meridian (R steep) Measurement in millimeters (mm) | Repeatability and reproducability across and between evaluations | One day |
| Mean Radius (Rm) Measurement in millimeters (mm) | Repeatability and reproducability across and between evaluations | One day |
| Corneal Cylinder Measurement in diopters (D) | Repeatability and reproducability across and between evaluations | One day |
| Corneal Cylinder Axis (A flat) Measurement in degrees | Repeatability and reproducability across and between evaluations | One day |
| Anterior Chamber Depth (ACD) Measurement in millimeters (mm) |
Not provided
Not provided
Inclusion Criteria:
Satisfies one of the subject group categories and the enrollment quota for that category has not been reached:
Manifest refraction sSpherical eEquivalent Refraction (MRSER) between -10dpt and +10dpt as measured by cycloplegic autorefraction assessed less than 12 months prior to enrollment
Best corrected visual acuity (BCVA) of LogMAR 0.2 or better
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Majid Moshirfar, MD | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ziemer Ophthalmic Systems AG | Port | Switzerland |
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Feb 22, 2020 | |
| Reset | Mar 6, 2020 | |
| Release | Jul 14, 2021 | |
| Reset | Aug 6, 2021 |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Feb 22, 2020 | Mar 6, 2020 | |||
| Jul 14, 2021 |
| ID | Term |
|---|---|
| D002386 | Cataract |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Oculus Pentacam AXL | Device | A single measurement of the eye will be taken using the Oculus Pentacam AXL |
|
Repeatability and reproducability across and between evaluations
| One day |
| Horizontal White-to-White distance (WtW) Measurement in millimeters (mm). | Repeatability and reproducability across and between evaluations | One day |
| Aug 6, 2021 |