This is a multicenter, prospective, single-arm study of the Optimizer Smart System with 2-leads
This is a multicenter, prospective, single-arm treatment only confirmatory study of the 2-lead configuration of the Optimizer Smart System.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Optimizer Smart System with 2-leads | Experimental | All eligible subjects will have the Optimizer Smart System implanted and receive cardiac contractility modulation therapy (CCM). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Optimizer Smart System with 2-leads | Device | The Optimizer Smart System with 2-leads delivers non-excitatory cardiac contractility modulating (CCM) electrical signals to the heart muscle. Implanted subjects receive five non-contiguous one-hour periods of CCM signals per day. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in exercise tolerance quantified by peak VO2 measured on cardiopulmonary exercise stress testing (CPX). | Device efficacy will be assessed as change in exercise tolerance quantified by peak VO2 measured on cardiopulmonary exercise stress testing (CPX). Subjects on device under FIX-HF-5C2 protocol will be compared to subjects on control under FIX-HF-5C protocol with respect to peak V02 mean change at 24-weeks from baseline. | 24 weeks |
| Optimizer-device and -procedure related complication rate | Subjects experiencing an Optimizer device- or procedure-related complication through the 24-week study period, as determined by an independent events committee. | 24 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Total CCM delivery comparing 2 and 3-lead device configurations | A comparison will be made between the Optimizer per-protocol groups in the FIX-HF-5C (3-lead) and FIX-HF-5C2 (2-lead) device configurations to show there is no difference between the amount of CCM therapy provided by the two device configurations. Total CCM delivery (effective hours delivered) will be evaluated at the end of 24 weeks following the Optimizer implantation. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| David D. Gutterman, MD | Medical College of Wisconsin | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Chan Heart Rhythm Institute | Mesa | Arizona | 85206 | United States | ||
| Southwest Cardiology Associates |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32264716 | Derived | Wiegn P, Chan R, Jost C, Saville BR, Parise H, Prutchi D, Carson PE, Stagg A, Goldsmith RL, Burkhoff D. Safety, Performance, and Efficacy of Cardiac Contractility Modulation Delivered by the 2-Lead Optimizer Smart System: The FIX-HF-5C2 Study. Circ Heart Fail. 2020 Apr;13(4):e006512. doi: 10.1161/CIRCHEARTFAILURE.119.006512. Epub 2020 Apr 8. |
Not provided
Not provided
Not provided
Optimizer Smart System
Not provided
Not provided
Not provided
Not provided
|
| 24 weeks |
| Mesa |
| Arizona |
| 85206 |
| United States |
| Cardiovascular Consultants | Phoenix | Arizona | 85032 | United States |
| Arizona Arrhythmia Consultants | Scottsdale | Arizona | 85251 | United States |
| Pima Heart Physicians, PC | Tucson | Arizona | 85712 | United States |
| Baptist Health Systems | Lexington | Illinois | 40503 | United States |
| Ochsner Clinic Foundation | New Orleans | Louisiana | 70121 | United States |
| Dallas VA Hospital | Dallas | Texas | 75216 | United States |
| CHRISTUS Trinity Mother Frances | Tyler | Texas | 75701 | United States |
| University Hospital gGmbH Bergmannsheil | Bochum | 44789 | Germany |
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Nov 11, 2020 | Dec 5, 2020 | 10 | ||
| Aug 23, 2021 | Sep 17, 2021 | 11 |
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided