When using suture (stitches) to close wounds, surgeons can use suture that is absorbable or non-absorbable. Absorbable sutures naturally break down. Non-absorbable sutures need to be removed. We wish to determine how the cosmetic result of a specific absorbable suture (fast absorbing gut) compares to that of a specific non-absorbable suture (prolene).
The purpose of this study is to determine whether the use of 5-0 prolene during repair of linear cutaneous surgery wounds improves scar cosmesis compared to wound closure with 5-0 fast absorbing gut (both SOC). We will use a split wound model, where half of the wound is treated with 5-0 prolene and the other half is repaired with 5-0 fast absorbing gut. Three-months post-surgery, the scar will be measured via the physician observer scar assessment scale, a validated scar instrument (research procedure). The scar width and adverse events will be recorded.
There are many options when it comes to closing a linear cutaneous wound, and an important consideration is choosing between non-absorbable and absorbable sutures. The overall aesthetic superiority between the two is not well understood. Studies to date have typically compared prolene (non-absorbable) and vicryl (absorbable) sutures and found no significant difference in cosmesis.1-4 One study found an increased pain score at 10 days with vicryl, but not at 6 weeks,1 while others have found no difference in pain.2-4 Another study found an increased number of complications with vicryl sutures, including infections and suture granulomas.4 This supports past observations that absorbable sutures can cause more of an immune response and therefore inflammation, despite the benefit of providing more prolonged support to wound edges compared to non-absorbable sutures.1
There is a lack of data, though, comparing prolene to other absorbable sutures, such as fast absorbing gut. In the setting of blepharoplasty, a study found that a running stitch of fast absorbing gut with a simple interrupted stitch of prolene at each end of the incision yielded better cosmetic results and fewer complications than a running stitch or subcuticular stitch using prolene.5 More studies are therefore needed to compare the outcomes of linear closures using only prolene compared to only fast absorbing gut. Using only absorbable sutures has the potential benefit of decreasing healthcare costs by reducing the number of appointments needed for suture removals, and, if superior in terms of cosmesis, corrective procedures.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 5-0 Prolene | Experimental | Half of the wound will be treated with 5-0 prolene |
|
| 5-0 Fast Absorbing Gut | Experimental | Half of the wound will be treated with 5-0 fast absorbing gut |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 5-0 Prolene, 5-0 Fast Absorbing Gut | Device | The interventions are two types of sutures: 5-0 Prolene, 5-0 Fast Absorbing Gut. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Patient Observer Scar Assessment Scale (POSAS) | The primary endpoint will be the score of two blinded reviewers using the physician observer assessment score at a three-month assessment visit. | within 3 months of the procedure |
| Measure | Description | Time Frame |
|---|---|---|
| Width of the scar | The secondary endpoint will include the width of the scar at the follow-up visit and any complications from the treatment. | within 3 months of the procedure |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Daniel Eisen, MD | University of California, Davis | Principal Investigator |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 270137 | Background | Zemla J. [Plastic operation of the alveolar process and associated deformities of the middle part of the face after primary operations for bilateral complete clefts of the lip, alveolar process and palate]. Protet Stomatol. 1977 Mar-Apr;27(2):143-4. No abstract available. Polish. | |
| 11281671 | Background | Erel E, Pleasance PI, Ahmed O, Hart NB. Absorbable versus non-absorbable suture in carpal tunnel decompression. J Hand Surg Br. 2001 Apr;26(2):157-8. doi: 10.1054/jhsb.2000.0545. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 21987279 | Background | Theopold C, Potter S, Dempsey M, O'Shaughnessy M. A randomised controlled trial of absorbable versus non-absorbable sutures for skin closure after open carpal tunnel release. J Hand Surg Eur Vol. 2012 May;37(4):350-3. doi: 10.1177/1753193411422334. Epub 2011 Oct 10. |
| 15368623 | Background | Menovsky T, Bartels RH, van Lindert EL, Grotenhuis JA. Skin closure in carpal tunnel surgery: a prospective comparative study between nylon, polyglactin 910 and stainless steel sutures. Hand Surg. 2004 Jul;9(1):35-8. doi: 10.1142/s0218810404002017. |
| 17545862 | Background | Joshi AS, Janjanin S, Tanna N, Geist C, Lindsey WH. Does suture material and technique really matter? Lessons learned from 800 consecutive blepharoplasties. Laryngoscope. 2007 Jun;117(6):981-4. doi: 10.1097/MLG.0b013e31804f54bd. |