The study assesses the effect of Closed Loop Stimulation (CLS) on the ventilatory efficiency slope and estimates the patient responder rate to CLS in patients with severe chronotropic incompetence treated with a cardiac resynchronization therapy (CRT) device.
In patients with pharmacological refractory heart failure (HF), systolic dysfunction, and cardiac dyssynchrony, the cardiac resynchronization therapy (CRT) reduces the risk of death, and improves symptoms and quality of life.
A considerable portion (80%) of patients with a CRT indication has a chronotropic incompetence (CI). CI usually induces a stress intolerance which negatively affects the quality of life. In addition of being a marker of diminished exercise capacity, severe CI (sCI) may be an independent predictor of mortality.
The sensor-based rate adaption provided by the implanted CRT device delivers a possible therapeutic approach for the CI.
Usually, rate adaption is achieved by an accelerometer. The previous studies in terms of effectiveness of rate adaption in CRT patients with CI showed inconsistent results.
In addition to an accelerometer to deliver the rate adaption BIOTRONIK provides closed loop stimulation (CLS) as unique feature in a CRT device. CLS determines the appropriate heart rate based on intra-cardiac impedance measurements. These measurements reflect changes of the cardiac contraction dynamics in reaction to information coming from the autonomic nervous system. CLS takes the information on the contraction dynamics and translates it into an adequate heart rate adaptation, thus delivering physiologically appropriate therapy.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Pacing mode with CLS | Active Comparator |
| |
| Intrinsic mode | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Cardiac Resynchronization therapy device with Closed Loop Stimulation (CLS) | Device | The feature CLS will be programmed ON or Off according to a randomization list after one month after baseline visit. One month later the alternate will be programmed. |
| Measure | Description | Time Frame |
|---|---|---|
| Ventilatory efficiency slope | The slope of VE/VCO2 describes the ventilatory efficiency during effort, showing the amount of air that must be ventilated to eliminate 1 litre of CO2. | 2 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mattias Roser, Dr. | Charité Universitätsklinikum - Campus Benjamin Franklin | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Charité Universitätsklinikum - Campus Benjamin Franklin | Berlin | Germany |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Patients are randomized in two different pacing modes (CLS versus intrinsic rhythm) after one month after enrollment. The cross-over takes place after one month after the randomization.
Not provided
Not provided
Not provided
|
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D058409 | Cardiac Resynchronization Therapy Devices |
| ID | Term |
|---|---|
| D010138 | Pacemaker, Artificial |
| D004566 | Electrodes |
| D055615 | Electrical Equipment and Supplies |
| D004864 | Equipment and Supplies |
Not provided
Not provided