The primary objective is to quantify and compare the three-dimensional kinematics of the cruciate retaining (CR), fixed bearing ATTUNETM TKA to the kinematics of the PFC Sigma Curved CR Fixed Bearing TKA (both DePuy Synthes, Johnson and Johnson) during daily activities.
The secondary objective is to describe the kinematics in terms of range of motion, patterns of anterior-posterior motion of the nearest medial and lateral points ("posterior femoral rollback") and tibio-femoral internal/external rotation as well as the kinetics during daily activities, such as level gait, a deep knee bend (only ATTUNETM subjects), sitting down onto a chair, standing up from a chair and stair descent by means of video-fluoroscopy.
Furthermore, the encoded data will be handed over to DePuy Synthes (Johnson and Johnson) and to the Center for Orthopaedic Engineering of the University of Denver, where it will be used within a musculoskeletal model with the aim of simulating tibiofemoral contact mechanics and changes in the musculoskeletal system due to the TKA.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| ATTUNE TM subjects |
| ||
| PFC Sigma subjects |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Observational use of fluoroscopy | Radiation |
|
| Measure | Description | Time Frame |
|---|---|---|
| Comparison of the three-dimensional kinematics of the cruciate retaining (CR), fixed bearing ATTUNETM TKA to the kinematics of the PFC Sigma Curved CR Fixed Bearing TKA | With video-fluoroscopic assessment it is possible to directly measure the kinematics of the tibial and the femoral components in vivo during daily activities, such as level walking, a deep knee bend (only ATTUNETM subjects), sitting down onto a chair, standing up from a chair and stair descent. Thus, for the first time the present study provides in vivo assessed data of the 3D motion of the ATTUNETM System during daily activities and allows a comparison to a conventional TKA based on the same methodology. The knowledge of the in vivo kinematic behaviour of the ATTUNETM System in comparison to the conventional TKA leads to an improved understanding of the design principle. | 3 hours |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
This is a prospective, observational study on 15 subjects with the ATTUNE TM CR Fixed Bearing TKA and 15 subjects with PFC Sigma Curved CR Fixed Bearing TKA during level walking, deep knee bend (only ATTUNE TM subjects), sitting down onto a chair, standing up from a chair and stair descent. The present study extends the subject groups of a previous feasibility study (KEK-ZH-Nr. 2014-0468) from 5 to 15 ATTUNE TM and from 6 to 15 PFC Sigma Curved CR Fixed Bearing TKA subjects. Based on a power analysis of the existing data of 5 ATTUNE TM subjects and 6 subjects with a PFC Sigma Curved CR Fixed Bearing TKA in the previous feasibility study (KEK-ZH-Nr. 2014-0468) the minimal sample size for the comparative evaluation of 15 subjects within each group was estimated. The participants must be able to perform the daily activity tasks mentioned above
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Institute for Biomechanics, ETH Zurich | Zurich | 8093 | Switzerland |
Not provided
Not provided
Not provided
Not provided