Not provided
Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| ANSM | Other Identifier | 2016-A01680-51 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Dental implants are a prosthetic rehabilitation device whose success depends of the bone morphology and quality, in more the surgical procedure.
This study aims to assess whether the parameters of the trabecular microarchitecture of alveolar bone taken from the site of the placement of the dental implant, calculated by micro-CT are correlated with ISQ (implant stability quotient) using the Osstell according the principle of the resonance frequency analysis at the 10th postoperative week during the osseointegration of dental implants (secondary stability).
The cortical alveolar bone is a recognized factor in the phase of primary stability of osseointegration. The role of trabecular bone in the secondary stability is not clearly determined.
The aim of this study is to check whether the trabecular bone with its microarchitecture plays a predictive role in osseointegration of dental implants precisely in its biological stability phase or its secondary stability phase.
If this correlation is established, a larger study must be conducted to identify a profile of patients at risk for failure of osseointegration of the dental implant.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| patients who need a dental implants |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| ISQ | Device | Measured by Osstell. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Implant Stability Quotient (ISQ) | The Osstell is a portable hand instrument used to measure the stability of the dental implant according to the principle of the resonance frequency analysis. It is allow to measure the ISQ. | 10 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| volume fraction of the bone | Measured by Scanco microscanner | 10 weeks |
| thickness between trabecular | Measured by Scanco microscanner |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients who need a dental implant
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Thierry THOMAS, MD PhD | Centre Hospitalier Universitaire de Saint Etienne | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Cabinet dentaire MOLIMARD | Le Puy-en-Velay | 43000 | France |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 10 weeks |
| Thickness of trabecular | Measured by Scanco microscanner | 10 weeks |
| trabecular separation | Measured by Scanco microscanner | 10 weeks |
| trabecular number | Measured by Scanco microscanner | 10 weeks |
| structural model index | Measured by Scanco microscanner | 10 weeks |
| trabecular pattern factor | Measured by Scanco microscanner | 10 weeks |
| connectivity density | Measured by Scanco microscanner | 10 weeks |
| degree of anisotropy | Measured by Scanco microscanner | 10 weeks |