Supraventricular tachycardia ablations of the Conformité Européenne (CE)-certified (since 2013) CartoUnivuTM module (Biosense Webster, Diamond Bar, USA) allows a seamless combination of a fluoro image and Carto® 3 System maps into a single view. This helps to reduce fluoroscopy levels and reduce exposure time for physicians, staff and patients to as low as reasonably achievable. The UnivuTM technology will be compared in a randomized manner to the conventional radiofrequency Ablation.
Aim of the current Randomized Clinical Study is to assess the safety and efficiency in supraventricular tachycardia ablations of the CE-certified (since 2013) CartoUnivuTM module (Biosense Webster, Diamond Bar, USA), allowing a seamless combination of a fluoro Image and Carto® 3 System maps into a single view. It helps reduce fluoroscopy levels - consistent with the ALARA principle of reducing exposure for physicians, staff and patients to as low as reasonably achievable. The UnivuTM technology will be compared in a randomized manner to the conventional radiofrequency (RF) ablation.
Patients with symptomatic supraventricular tachycardia (SVT) will be included, more specifically patients with atrioventricular nodal re-entrant tachycardia (AVRNT), atrioventricular re-entrant tachycardia (AVRT) and typical atrial flutter (TAF). Current ablative treatment consists in destroying small areas of myocardial tissue or conduction system, or both, that are critical to the initiation or maintenance of the arrhythmia (slow pathway Ablation in the case of AVRNT, anomalous extra nodal connections between the atrium and ventricle along the atrioventricular groove in AVRT and cavo-tricuspid isthmus in the case of TAF).
However, SVT ablations without a 3D navigation system have a certain fluoroscopy time and radiation exposure, respectively. Prolonged fluoroscopy and radiation exposure during ablation may potentially cause an increase in the lifetime risk of fatal malignancy.
In a 1-year follow-up the arrhythmia recurrence rate without anti-arrhythmic drugs will be assessed using 7-day holter recording in 60 patients undergoing CartoUnivuTM guided SVT ablation (group A) vs. 60 patients undergoing conventional RF-catheter ablation (without CartoUnivuTM, group B).
All patients will stop anti-arrhythmic drugs at least 1 week before the date of ablation. Each patient will undergo transthoracal echocardiography (TTE) before the intervention. In case transseptal is needed, heparin will be administered after successful transseptal puncture with an activated clotting time (ACT)-target ≥325 sec.
Following data will be acquired:
Ablation for SVT:
The following concept will be used for ablation of the slow pathway ablation in the case of AVRNT, anomalous extra nodal connections between the atrium and ventricle along the atrioventricular groove in AVRT and cavo-tricuspid isthmus in the case of TAF: Using the 3D-electro-anatomic system (CARTO3®) with the module for fluoroscopy integration (UnivuTM), the diagnostic catheters (10 poles deflectable catheter and fixed 4 poles catheter) will be introduced without using fluoroscopy after the registration phase and the transfer of a fluoroscopic image in anteroposterior (AP) and left anterior oblique (LAO) projections into the Carto3® System.
Once the electrophysiology study is realized and the arrhythmia identified (an activation can be used for this purpose), the ablation catheter (Navistar® 4mm/8mm, Biosense Webster, Diamond Bar, USA) is then introduced (also without the use of fluoroscopy). In case no map was done for local activation time information, specific tags will be taken:
Aim of the ablation procedure is to ablate small areas of myocardial tissue or conduction system, or both, that are critical to the initiation or maintenance of the arrhythmia (slow pathway ablation in the case of AVRNT, anomalous extra nodal connections between the atrium and ventricle along the atrioventricular groove in AVRT and cavo-tricuspid isthmus in the case of TAF) using the CartoUnivuTM module (Biosense Webster, Diamond Bar, USA) for fluoroscopy integration on the Carto 3® System, with no further arrhythmia inducibility.
If a non-clinical arrhythmia corresponding to the patient symptoms is induced, pharmacological and/or electrical cardioversion in to sinus rhythm will be performed. If a coronariography is performed, the procedure time, fluoroscopy time and doses used will be discounted from the overall respective measurements.
Annotation of ablation sites on the 3D-map must be performed only by the VisiTag algorithm (integrated in the CARTO3® system), which will allow post-procedural analysis of catheter stability at each RF delivery site, duration of RF-application values and catheter stability during ablation.
The following procedural data will be acquired:
Follow-up:
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| ALARA protocol | Active Comparator | SVT ablation by ALARA protocol |
|
| current treatment | Active Comparator | SVT ablation by conventional protocol |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| SVT ablation by ALARA protocol | Procedure | Catheter ablation is a procedure that uses radiofrequency energy (similar to microwave heat) to destroy a small area of heart tissue that is causing arrhythmias. Destroying this tissue helps restore your heart's regular rhythm. The usage of CartoUnivuTM allows a seamless combination of a fluoro image and Carto® 3 System maps into a single view. |
| Measure | Description | Time Frame |
|---|---|---|
| recurrence of arrhythmia documented by ECGs | Documentation by ECG,7-day-holter ECG, symptoms description by the patient | within 90 days after the ablation procedure |
| Measure | Description | Time Frame |
|---|---|---|
| total fluoroscopy time in minutes | fluoroscopy time measured in minutes administered during the Ablation procedure | during the ablation procedure |
| total radiation exposure in gy | Exposition of the Patient to Radiation during the ablation procedure measured in gy |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Richard Kobza, PD Dr. med. | Luzerner Kantonsspital | Principal Investigator |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| SVT ablation by conventional protocol | Procedure | Catheter ablation is a procedure that uses radiofrequency energy (similar to microwave heat) to destroy a small area of heart tissue that is causing arrhythmias. Destroying this tissue helps restore your heart's regular rhythm. The convention Ablation procedure works without a 3D navigation System. |
|
|
| during the ablation procedure |
| Duration of Ablation procedure in minutes | time needed to complete the procedure | skin to skin of the ablation procedure |
| Composite adverse events | Death of any cause, bleeding, vascular complications, and high-degree atrioventricular block | within the first 30 days post ablation procedure |