| Primary | Number of Eyes That Failed Treatment | Treatment failure is defined as meeting one or more of the following 4 criteria:
- Intraocular pressure (IOP) a) >18 mm Hg on maximum tolerated topical IOP-lowering medications, or b) Reduction of < 20% IOP on maximum tolerated topical IOP-lowering medications from medicated preoperative IOP, or c) ≤ 5 mm Hg without IOP-lowering medications on IOP confirmation visit, 6 months after initial study intervention; or
- Reoperation for glaucoma; or
- Addition of an oral CAI for the study eye on or after the 6-Month Study Visit; or
- Loss of light perception vision (NLP).
| Only one eye of each participant was eligible for enrollment. Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Number | | eyes | | from time of intervention to month 6 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| | | Title | Denominators | Categories |
|---|
| | |
| |
| Primary | Number of Eyes That Failed Treatment | Treatment failure is defined as meeting one or more of the following 4 criteria:
- Intraocular pressure (IOP) a) >18 mm Hg on maximum tolerated topical IOP-lowering medications, or b) Reduction of < 20% IOP on maximum tolerated topical IOP-lowering medications from medicated preoperative IOP, or c) ≤ 5 mm Hg without IOP-lowering medications on IOP confirmation visit, 6 months after initial study intervention; or
- Reoperation for glaucoma; or
- Addition of an oral CAI for the study eye on or after the 6-Month Study Visit; or
- Loss of light perception vision (NLP).
| Only one eye of each participant was eligible for enrollment. Data for this outcome measure were not collected for 4 in the Second Aqueous Shunt arm and 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Number | | eyes | | from month 6 to month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
|
| Primary | Number of Eyes That Failed Treatment | Treatment failure is defined as meeting one or more of the following 4 criteria:
- Intraocular pressure (IOP) a) >18 mm Hg on maximum tolerated topical IOP-lowering medications, or b) Reduction of < 20% IOP on maximum tolerated topical IOP-lowering medications from medicated preoperative IOP, or c) ≤ 5 mm Hg without IOP-lowering medications on IOP confirmation visit, 6 months after initial study intervention; or
- Reoperation for glaucoma; or
- Addition of an oral CAI for the study eye on or after the 6-Month Study Visit; or
- Loss of light perception vision (NLP).
| Only one eye of each participant was eligible for enrollment. Only those who did not fail treatment in the previous time period (previous time period is reported in Outcome measure 2) were analyzed in this time period. Data for this outcome measure were not collected for 15 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Number | | eyes | | from month 12 to year 3 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation |
|
| Secondary | Number of Eyes With Vision-threatening Complications | | Only one eye of each participant was eligible for enrollment. Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Number | | eyes | | from the time of intervention to year 3 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Number of Eyes That Lost Two or More Lines of Vision as Assessed by the Snellen Chart Visual Acuity Test | The Snellen visual acuity test is used to determine the smallest letters the participant can read on a standardized chart (Snellen chart). Loss of lines of vision indicates worsening visual acuity. | Only one eye of each participant was eligible for enrollment. Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Number | | eyes | | from time of intervention to year 3 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Change in Visual Acuity as Assessed by the Snellen Chart Visual Acuity Test | The visual acuity test is used to determine the smallest letters the participant can read on a standardized chart (Snellen chart). The week 1 reading minus the baseline reading is reported, with a positive number indicating a decrease in visual acuity (that is, an increase in logMAR value indicates a decrease in visual acuity). | Data for this outcome measure was not collected 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | log MAgnification Requirement (logMAR) | | baseline, week 1 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Change in Visual Acuity as Assessed by the Snellen Chart Visual Acuity Test | The visual acuity test is used to determine the smallest letters the participant can read on a standardized chart (Snellen chart). The month 1 reading minus the baseline reading is reported, with a positive number indicating a decrease in visual acuity (that is, an increase in logMAR value indicates a decrease in visual acuity). | Data for this outcome measure was not collected for 5 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | log MAgnification Requirement (logMAR) | | baseline, month 1 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Change in Visual Acuity as Assessed by the Snellen Chart Visual Acuity Test | The visual acuity test is used to determine the smallest letters the participant can read on a standardized chart (Snellen chart). The month 3 reading minus the baseline reading is reported, with a positive number indicating a decrease in visual acuity (that is, an increase in logMAR value indicates a decrease in visual acuity). | Data for this outcome measure were not collected for 1 in the Second Aqueous Shunt arm and 3 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | log MAgnification Requirement (logMAR) | | baseline, month 3 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
|
| Secondary | Change in Visual Acuity as Assessed by the Snellen Chart Visual Acuity Test | The visual acuity test is used to determine the smallest letters the participant can read on a standardized chart (Snellen chart). The month 6 reading minus the baseline reading is reported, with a positive number indicating a decrease in visual acuity (that is, an increase in logMAR value indicates a decrease in visual acuity). | Data for this outcome measure were not collected for 3 in the Second Aqueous Shunt arm and 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | log MAgnification Requirement (logMAR) | | baseline, month 6 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
|
| Secondary | Change in Visual Acuity as Assessed by the Snellen Chart Visual Acuity Test | The visual acuity test is used to determine the smallest letters the participant can read on a standardized chart (Snellen chart). The month 12 reading minus the baseline reading is reported, with a positive number indicating a decrease in visual acuity (that is, an increase in logMAR value indicates a decrease in visual acuity). | Data for this outcome measure were not collected for 6 in the Second Aqueous Shunt arm and 4 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | log MAgnification Requirement (logMAR) | | baseline, month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
|
| Secondary | Change in Visual Acuity as Assessed by the Snellen Chart Visual Acuity Test | The visual acuity test is used to determine the smallest letters the participant can read on a standardized chart (Snellen chart). The year 2 reading minus the baseline reading is reported, with a positive number indicating a decrease in visual acuity (that is, an increase in logMAR value indicates a decrease in visual acuity). | Data for this outcome measure were not collected for 16 in the Second Aqueous Shunt arm and 11 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | log MAgnification Requirement (logMAR) | | baseline, year 2 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
|
| Secondary | Change in Visual Acuity as Assessed by the Snellen Chart Visual Acuity Test | The visual acuity test is used to determine the smallest letters the participant can read on a standardized chart (Snellen chart). The year 3 reading minus the baseline reading is reported, with a positive number indicating a decrease in visual acuity (that is, an increase in logMAR value indicates a decrease in visual acuity). | Data for this outcome measure were not collected for 16 in the Second Aqueous Shunt arm and 15 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | log MAgnification Requirement (logMAR) | | baseline, year 3 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
|
| Secondary | Incidence of Pain | Number of participants who reported pain. | Data for this outcome measure were not collected for 1 in the Second Aqueous Shunt arm and 2 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Count of Participants | | Participants | | 1 week | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Incidence of Pain | Number of participants who reported pain. | Data for this outcome measure were not collected for 2 in the Second Aqueous Shunt arm and 2 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Count of Participants | | Participants | | 1 month | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Severity of Pain | Severity of pain was assessed by the Universal Pain Assessment Tool, and the score ranges from 0 to 10, with a higher score indicating greater pain. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm and 2 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | 1 week | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Severity of Pain | Severity of pain was assessed by the Universal Pain Assessment Tool, and the score ranges from 0 to 10, with a higher score indicating greater pain. | Data for this outcome measure were not collected for 2 in the Second Aqueous Shunt arm and 2 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | 1 month | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Number of Office Visits Per Participant From Baseline to 3 Months | | Data for this outcome measure were not collected 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | office visits per participant | | from baseline to 3 months | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Number of Office Visits Per Participant Per Month After Month 3 | | Data for this outcome measure were not collected for 2 in the Second Aqueous Shunt arm and 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | office visits per participant per month | | from month 4 to year 3 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute (NEI) Visual Function Questionnaire (VFQ) 25 (NEI-VFQ-25) - General Health Subscale | The score on the National Eye Institute (NEI) Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - General Health Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - General Vision Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - General Vision Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Mental Health Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Mental Health Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Distance Activity Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Distance Activity Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Near Activity Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Near Activity Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Peripheral Vision Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Peripheral Vision Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Color Vision Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Color Vision Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Ocular Pain Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Ocular Pain Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Driving Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Driving Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Dependency Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Dependency Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Social Functioning Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Social Functioning Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Role Difficulty Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 1 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | baseline | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |
| Secondary | Vision-related Quality of Life as Assessed by the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) - Role Difficulty Subscale | The score on the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25) subscale ranges from 0 to 100, with a higher score indicating greater functioning. | Data for this outcome measure were not collected for 8 in the Second Aqueous Shunt arm and 7 in the Transscleral Cyclophotocoagulation arm who received the intervention. | Posted | | Mean | Standard Deviation | score on a scale | | month 12 | | | | ID | Title | Description |
|---|
| OG000 | Second Aqueous Shunt | Second Aqueous Shunt Either a Baerveldt Glaucoma Implant 350-mm2 BG101-350 or an Ahmed Model FP7 Flexible Plate must be used for all participants unless there is insufficient space, in which case a Baerveldt Glaucoma Implant 250-mm2 BG103-250 may be used. Baerveldt Glaucoma Implant 350-mm2 / BG101-350 Ahmed Model FP7 Flexible Plate Baerveldt Glaucoma Implant 250-mm2 / BG103-250 | | OG001 | Transscleral Cyclophotocoagulation | Transscleral Diode Laser Cyclophotocoagulation Transscleral Diode Laser Cyclophotocoagulation: Recommended setting are 2000 milliwatt (mW) for 2 seconds, 1850 mW for 3 seconds or 1750 mW for 4 second duration, titrating the energy up or down just below where a pop is heard. |
| |