This study will compare near clinical oculomotor parameters (heterophoria, vergence ranges, AC/A and accommodative findings) measured when lenses and/or prisms are introduced using three different instruments namely: (i) a standard manual phoropter, (ii) an electronic phoropter and (iii) a wearable adaptive refractor (VisionFit).
Previous studies have demonstrated differences in a number of near oculomotor parameters [e.g., heterophoria, accommodative convergence to accommodation (AC/A) ratio] when measured in a manual phoropter versus a trial frame. These differences may be due to variations in proximal vergence, differences in head and eye position and restriction of the peripheral visual field. Further, a number of standard clinical oculomotor procedures require the use of Risley rotary prisms. While prism is typically introduced in a smooth, ramp-like fashion with manual phoropters, step changes in prism are created with electronic phoropters. The precise effect of these variations on clinical measurements is unclear. Accordingly, after a routine refractive examination, a standard clinical near assessment (comprising near heterophoria, AC/A ratio, horizontal vergence ranges, amplitude of accommodation and negative and positive relative accommodation) will be carried out on the same individuals through: (i) a standard manual phoropter (American Optical model 11625), (ii) an electronic phoropter (Topcon CV-5000) and (iii) a wearable adaptive refractor (VisionFit). The latter resembles a trial frame mounted on a helmet carrier (similar to a binocular indirect ophthalmoscope headset) but includes adaptive lenses that can be changed electronically.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Phoropter | Experimental | Each subject will be tested on 3 separate occasions using either the manual phoropter (American Optical 11625), electronic phoropter (Topcon CV-5000) or the wearable adaptive refractor (VisionFit). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Phoropter | Device | Each subject will be tested on 3 separate occasions using either the manual phoropter (American Optical 11625), electronic phoropter (Topcon CV-5000) or the wearable adaptive refractor (VisionFit). Oculomotor measurements, i.e., heterophoria, vergence ranges, AC/A and accommodative findings will be measured at each session using the different devices. Each session will be separated by a minimum of 24 hours and a maximum of 14 days. |
| Measure | Description | Time Frame |
|---|---|---|
| Near horizontal heterophoria | Near horizontal heterophoria (measured in prism diopters) will be recorded using both the Von Graefe and Modified Thorington techniques using each of the three lens presentation devices. The single set of measurements will be recorded approximately 15 minutes after the start of the trial. | approximately 15 minutes |
| Accommodative convergence to accommodation (AC/A) ratio | The AC/A ratio will be calculated from measurements of near horizontal heterophoria (quantified in prism diopters) will be recorded using the Modified Thorington technique at 3 different accommodative stimulus levels (1.5D, 2.5D and 3.5D). Measurements will be obtained using each of the three lens presentation devices and calculated in units of prism diopter per diopter accommodation.The single set of measurements will be recorded approximately 15 minutes after the start of the trial. | approximately 15 minutes |
| Horizontal near vergence ranges | Near base-in and base-out vergence ranges will be measured (in prism diopters) while the subject fixates a near target. Measurements will be expressed in terms of the blur point, break point and recovery measurement .The single set of measurements will be recorded approximately 15 minutes after the start of the trial. | approximately 15 minutes |
| Minus lens amplitude of accommodation | Minus lens amplitude of accommodation (measured in diopters) will be recorded using each of the three lens presentation devices.The single set of measurements will be recorded approximately 15 minutes after the start of the trial. | approximately 15 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| Negative and Positive Relative Accommodation (NRA and PRA) | NRA and PRA (measured in diopters) will be recorded using each of the three lens presentation devices.The single set of measurements will be recorded approximately 15 minutes after the start of the trial. | approximately 15 minutes |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mark Rosenfield, MCOptom, PhD | State University of New York College of Optometry | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| SUNY College of Optometry | New York | New York | 10036 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D014786 | Vision Disorders |
| ID | Term |
|---|---|
| D012678 | Sensation Disorders |
| D009461 | Neurologic Manifestations |
| D009422 | Nervous System Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| D012816 |
| Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |