Eye Care Professionals (ECPs) massively use auto-refractors during the patient journey to measure the objective refractive error: starting point of the subjective eye refraction. These devices provide objective information about the refractive and accommodative state of the eye, useful for the ECP to perform a complete eyesight test. Auto-refractor data for the distance vision are repeatable and accurate but near vision information are not enough reliable to build an accurate near vision routine exam. Previous internal studies, with auto refractors currently on the market, have shown that, during accommodation measurements, a large proportion of participants had a lower accommodative response than expected.
Clinical Development stage and rationale
The clinical development stage is pilot stage as defined in ISO 14155:2020 (Annex I section 1.3.2).This clinical investigation is an exploratory clinical investigation as mentioned in the Medical Device Regulation EU 745/2017, also named early feasibility clinical investigation in the ISO 14155:2020. The necessity of such clinical investigations is more precisely described by the Food and Drug Administration (FDA) (Attachment E CDRH Final Guidance Cover Sheet) and Agence Nationale de Sécurité du Médicament et des produits de santé (ANSM), where they detail the importance of exploratory studies in pivotal investigation design.
Medical devices often undergo design improvement during development, with refinement during lifecycles beginning with early research, extending through investigational use and initial marketing of the approved or cleared product, and continuing to subsequently approved or cleared commercial device versions.
Objectives and hypotheses of the clinical investigation
This clinical investigation explores new ways of measuring accommodative response, particularly regarding the dynamics and amplitude of response: we chose to vary several parameters.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Closed-field Aberrometer | Experimental | Objective refraction at different distances with Shack-Hartmann Aberrometer |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Visual acuity | Device | VA will be measured with an Early Treatment Diabetic Retinopathy Study (ETDRS) chart |
|
| Measure | Description | Time Frame |
|---|---|---|
| Accommodative response measured with closed-field aberrometer with different target displacement methods | Accommodative response (Dioptries) | One day (measurements are taken during the single visit) |
| Accommodative response measured with closed-field aberrometer with different displayed targets | Accommodative response (Dioptries) | One day (measurements are taken during the single visit) |
| Objective refraction measured with closed-field aberrometer and two camera exposure times | Sphere (Dioptries), Cylinder (Dioptries), Axis (°) and High Order Aberrations (Zernike polynomials) | One day (measurements are taken during the single visit) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Thierry Laloux | Contact | +33 (1) 55 96 54 05 | lalouxt@essilor.fr |
| Name | Affiliation | Role |
|---|---|---|
| Jérôme Gillet | ESSILOR INTERNATIONAL - Division Instruments | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Essilor International - Ci&T 2 | Recruiting | Créteil | 94000 | France |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Objective refraction | Device | Objective refraction will be measured using an auto-kerato-refractometer/aberrometer |
|
| Objective monocular accommodation amplitude measurement | Device | Objective monocular accommodation amplitude measurements are obtained dynamically by measuring the subject's dioptric change while the participant focuses on a virtual object that moves from distance |
|
| Subjective monocular accommodation amplitude measurement with the "Push-Up" method | Device | The subjective monocular accommodation amplitude measurements are carried out by the "push-up" method and proceeds as follows:
The amount of accommodation in this eye is equal to the proximity (= 1/distance) of the test when the blur is just perceived. |
|
| Subjective monocular accommodation facility measurement with the "Rock" method: | Device | The subjective monocular accommodation facility measurements are carried out by the "Rock" method and proceeds as follows:
|
|
| CISS Questionnaire | Other | This questionnaire relating to the use of the near vision will be submitted |
|
| Difficulty assessment questionnaire | Other | After each near vision measurement, the participant should rate, on a Visual Analogic Score (0-10), the difficulty encountered, from 0: extremely easy to 10: extremely difficult. The participant may also specify the reasons for the difficulty(ies) encountered during the measurement. |
|
| Subjective evaluation questionnaire | Other | A subjective evaluation questionnaire will be submitted to the participants at the end of the visit. |
|
| ID | Term |
|---|---|
| D014792 | Visual Acuity |
| C000728119 | Coping Inventory for Stressful Situations |
| ID | Term |
|---|---|
| D014787 | Vision Tests |
| D003941 | Diagnostic Techniques, Ophthalmological |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
| D009799 | Ocular Physiological Phenomena |
Not provided
Not provided