The investigators sought to investigate the efficacy of low frame rate (fluoroscopy at 7.5 frames per second (FPS) and Cine at 10 pulse per second (PPS) vs. conventional (15 FPS and 15 PPS) on radiation dose to the patient and the operator during coronary angiography and intervention. In addition, investigators sought to qualitatively assess the effect, if any, of the low frame rate on angiographic image quality.
Minimizing radiation exposure to patient and the operator is considered one of the primary safety concerns in the catheterization laboratory. Patients undergoing diagnostic angiography +/- ad hoc PCI or planned PCI, will be randomised to conventional settings (15 FPS and 15 PPS) or low frame rate settings (7.5 FPS and 15 PPS) or low Cine settings (7.5 FPS and 10 PPS). The patient radiation dose, patient radiation dose area product (DAP), and fluoroscopy time will be measured.
Statistical Analysis:
Demographic and procedural variables will be presented as percentage (categorical variable) or mean ± SD (continuous variable). Patients will be randomized into three arms - a control arm and two intervention arms. The angiographic radiation protocol will adhere to standard practice in both fluoroscopy and cine images at 15 frames/second. The intervention arm will consist of two groups. Group 1 with fluoroscopy images set at 7.5 frames/second and cine images set at 15 frames/second and group 2 with fluoroscopy set at 7.5 frames/second and cine set at 10 frames/second.
Sample size calculations are based on assuming a reduction in radiation dose in group 1 of 10% and in group 2 of 20%. At 5% significance and 80% power, a sample size of 200 patients will be required in each intervention arm. Allowing for a 10% attrition rate, a sample size of 220 patients will be required in each intervention arm with 100 patients in the control arm.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Conventional rate fluoroscopy | Active Comparator | Radiation: 15 FPS Cine 15 PPS |
|
| Intermediate frame rate 7.5 fps | Experimental | Radiation: 7.5 low Frame rate |
|
| Low frame rate | Experimental | Low Cine 10 PPS |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Radiation: 15 FPS Cine 15 PPS | Radiation | Radiation 15 FPS Cine 15 PPS |
|
| Measure | Description | Time Frame |
|---|---|---|
| Radiation Exposure to patient | Radiation exposure to patient will be measured by Dose-Area product (DAP) collected during the procedure. | During Cardiac catheterization procedure |
| Measure | Description | Time Frame |
|---|---|---|
| Image quality assessment of the coronary angiogram | Coronary angiograms will be assessed by blinded operators for quality of image using a pre-specified tool | 12 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Divyesh Sharma, MSc,MRCP | Contact | 001-647-961-9336 | divyeshsharma11@gmail.com | |
| Ashish H Shah, MD, MD(Res) | Contact | 001-416-835-2822 | ashish.shah@uhn.ca |
| Name | Affiliation | Role |
|---|---|---|
| Vladimir Dzavik, MD, FRCPC | UHN, Toronto, Canada | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Health Network - Peter Munk Cardiac Centre | Toronto | Ontario | Canada |
Not provided
| ID | Term |
|---|---|
| D060050 | Angina, Stable |
| D000789 | Angina, Unstable |
| D054058 | Acute Coronary Syndrome |
| D004194 | Disease |
| ID | Term |
|---|---|
| D000787 | Angina Pectoris |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D003226 | Congresses as Topic |
| ID | Term |
|---|---|
| D009938 | Organizations |
| D004472 | Health Care Economics and Organizations |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Radiation: 7.5 low Frame rate | Radiation | Radiation: Frame rate 7.5 FPS, Cine 15 PPS |
|
|
| Low Cine | Radiation | Radiation: Frame rate 7.5 FPS, Cine 10 PPS |
|
|
| D014652 |
| Vascular Diseases |
| D002637 | Chest Pain |
| D010146 | Pain |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D010335 | Pathologic Processes |