The latest findings on the ergogenic effects of a dentistry-design, bite-aligning mouthpiece require additional research to assess its impact on anaerobic ability and ventilatory parameters. This study was aimed at determining the ergogenic acute effects of wearing a custom-made mouthpiece on oral airflow dynamics, Wingate Test performance parameters.
The objectives of this study are to investigate the acute effects of a customized, bite-aligning mouthpiece on the different parameters assessed during a Wingate Test, as compared to clenching the jaw without a mouthpiece, in a physically-active, male population. The study also investigate the influence of wearing a mouthpiece on non-forced and forced airflow dynamics, as compared to open mouth and a jaw clenching without mouthpiece. Mouthpieces are made using a new scanning method that simplified the fitting process and lowered its cost.
A nonrandomized study was designed to compare the effect of the occlusion condition on the anaerobic power and airflow dynamics. Conditions of wearing or not wearing mouthguard (MOUTHG and NO-MOUTHG, respectively) are randomly distributed in all tests. Each subject participate in three sessions. The first session is used to obtain informed consent assess anthropometric measurements and to scan the subject's mouth structure. In the second session, subjects are familiarized with the test protocols via a learning session that included demonstration of Wingate Test and the airflow dynamics measurements. Subjects also perform the airflow tests and the first Wingate Test trial. In the third session, subjects perform the second Wingate Test trial. Conditions are randomly distributed in all tests. Wingate Test trials were separated by three days and subjects were not allowed to perform intensive training workloads.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Mouthguard | Experimental | All subjects perform all tests wearing mouthguard. |
|
| No mouthguard | Experimental | All subjects perform all tests without mouthguard |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Mouthguard | Device | Condition of wearing mouthguard |
| |
| No mouthguard |
| Measure | Description | Time Frame |
|---|---|---|
| Changes in performance in Wingate test | Anaerobic power and capacity are assessed using the Wingate test with and without mouthguard (MOUTHG and NO-MOUTHG, respectively). Subjects complete a 30-sec maximal effort on an ergometer at a resistance equivalent to 7.5% of their body mass. The ergometer is interfaced with a computer loaded with software (Wingate Software Version 1.11, Lode BV) that apply the appropriate load for each subject. As a warm-up procedure, subjects are instructed to begin pedaling for 5 minutes at 100 W and approximately 60 rpm. After a 5 second count down and without altering the mentioned parameters, subjects are asked to begin pedaling as fast as possible while receiving verbal encouragement throughout the test. Peak power (W) and mean power (W) are calculated and recorded in an online data acquisition system. | 3 trials spaced 48 hours (each trial 30 seconds) |
| Changes in performance dynamics airflow measurements. | Subjects are asked to breath at resting pace during 30-sec under three different conditions: open mouth without mouthguard, jaw clenching without mouthguard and jaw clenched with mouthguard (OMNM, JCNM and JCM, respectively). Subjects intercalate 30 second forced breathings under the same conditions. Rest time was 3 minutes after both measurements under each condition. Conditions are randomly distributed. Facemask and is connected to a Biopac MP100 system through the wide-range airflow transducer amplifier. Peak air flow is detected and mean air flow during the 30 second interval is calculated for all conditions in L•min-1. | 3 trials spaced 3 minutes (each trial 30 seconds) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Xavier Pujades, PHD | Vicedagà Facultat ciències de l'Esport Blanquerna | Study Chair |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| Background | Arent, S. M., McKenna, J.and Golem, D. L. (2010). Effects of a neuromuscular dentistry-designed mouthguard on muscular endurance and anaerobic power. Comparative Exercise Physiology, 7(02), 73-79. | ||
| 25264671 | Background | Bailey SP, Willauer TJ, Balilionis G, Wilson LE, Salley JT, Bailey EK, Strickland TL. Effects of an over-the-counter vented mouthguard on cardiorespiratory responses to exercise and physical agility. J Strength Cond Res. 2015 Mar;29(3):678-84. doi: 10.1519/JSC.0000000000000668. | |
| 19583574 |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D009058 | Mouth Breathing |
| D053120 | Respiratory Aspiration |
| ID | Term |
|---|---|
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D009064 | Mouth Protectors |
| ID | Term |
|---|---|
| D011313 | Preventive Dentistry |
| D003813 | Dentistry |
| D011482 | Protective Devices |
| D004864 | Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
Condition without mouthguard |
|
| Background |
| Cetin C, Kececi AD, Erdogan A, Baydar ML. Influence of custom-made mouth guards on strength, speed and anaerobic performance of taekwondo athletes. Dent Traumatol. 2009 Jun;25(3):272-6. doi: 10.1111/j.1600-9657.2009.00780.x. |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D010335 | Pathologic Processes |
| D000067393 |
| Personal Protective Equipment |
| D008420 | Manufactured Materials |
| D013676 | Technology, Industry, and Agriculture |