PANDA III is sought to investigate the safety and efficacy of a PLGA-polymer with electro-grafting base layer sirolimus-eluting stent (SES) versus a PLA-polymer SES at 12 months follow-up.
The BuMA stent (SINOMED, Beijing, China) was a novel biodegradable PLGA polymer sirolimus-eluting stent (SES), with design of adding an electro-grafting (eG) base layer between the polymer and the stainless steel stent strut.The eG layer can secure adhesion of the biodegradable PLGA coating as a result of the interdigitation, and the PLGA coating ensures 100% drug release within 30 days.The initial investigation showed a high strut coverage rate in both the BuMA stent and the Xience V stent at 3 months follow-up. Moreover, earlier vascular healing after drug-eluting stent implantation may reduce the incidence of stent thrombosis at follow-up and potentially shorten dual antiplatelet therapy duration. Therefore, we performed this randomized trial to investigate 12 months target lesion failure between the BuMA and the EXCEL stent, both with same eluted drug sirolimus, however different biodegradable polymer carriers.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| BuMA group | Experimental | Implant BuMA stent only |
|
| EXCEL group | Active Comparator | Implant EXCEL stent |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| BuMA | Device | This group will contain 1175 subjects. |
| |
| EXCEL |
| Measure | Description | Time Frame |
|---|---|---|
| Target lesion failure (a composite of cardiac death, target lesion myocardial infarction and ischemia driven target lesionsrevascularization TLR) at 1 year | 12 months after PCI |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Runlin Gao, Dr | Fuwai Hospital, Chinese Academy of Medical Science | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Fuwai hospital | Beijing | 100037 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 38143084 | Derived | He J, Bian X, Zhang R, Yuan S, Guan C, Zou T, Liu L, Song C, Xie L, Wang H, Qiao Z, Yin D, Xu B, Dou K. Impact of Relative Improvement in Quantitative Flow Ratio on Clinical Outcomes After Percutaneous Coronary Intervention - A Subanalysis of the PANDA III Trial. Circ J. 2024 May 24;88(6):921-930. doi: 10.1253/circj.CJ-22-0743. Epub 2024 Jan 27. | |
| 35331810 |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
This group will contain 1175 subjects. |
|
| Zhang R, Wu S, Yuan S, Guan C, Zou T, Qiao Z, Xie L, Wang H, Song L, Xu B, Dou K. Effects of diabetes mellitus on post-intervention coronary physiological assessment derived by quantitative flow ratio in patients with coronary artery disease underwent percutaneous coronary intervention. Diabetes Res Clin Pract. 2022 Apr;186:109839. doi: 10.1016/j.diabres.2022.109839. Epub 2022 Mar 21. |
| 35101540 | Derived | Zhang R, Xu B, Dou K, Guan C, Zhao Y, Wang X, Zou T, Qiao Z, Xie L, Wang H, Yuan S, Song L, Tu S, Wang Y, Wijns W. Post-PCI outcomes predicted by pre-intervention simulation of residual quantitative flow ratio using augmented reality. Int J Cardiol. 2022 Apr 1;352:33-39. doi: 10.1016/j.ijcard.2022.01.054. Epub 2022 Jan 31. |
| 34219669 | Derived | Zhang R, Dou K, Guan C, Zou T, Zhang M, Yuan S, Qiao Z, Xie L, Sun Z, Song L, Qiao S, Stone GW, Xu B. Outcomes of quantitative flow ratio-based percutaneous coronary intervention in an all-comers study. EuroIntervention. 2022 Feb 18;17(15):1240-1251. doi: 10.4244/EIJ-D-21-00176. |
| 33040580 | Derived | Zhang R, Song C, Guan C, Liu Q, Wang C, Xie L, Sun Z, Cai M, Zhang M, Wang H, Liu J, Dou K, Xu B. Prognostic Value of Quantitative Flow Ratio Based Functional SYNTAX Score in Patients With Left Main or Multivessel Coronary Artery Disease. Circ Cardiovasc Interv. 2020 Oct;13(10):e009155. doi: 10.1161/CIRCINTERVENTIONS.120.009155. Epub 2020 Oct 12. |
| 30990245 | Derived | Jia S, Guan C, Yuan J, Cao X, Qin L, Li Y, Li Z, Nie S, Hou S, Zhang M, Brouwer M, Suryapranata H, Xu B, Gao R. Two-year safety evaluation of a biodegradable polymer sirolimus-eluting stent with increased drug elution and polymer absorption kinetics in complex patient and lesion cohort. Catheter Cardiovasc Interv. 2020 Feb;95(2):206-215. doi: 10.1002/ccd.28288. Epub 2019 Apr 16. |
| 29747321 | Derived | Wang J, Guan CD, Yuan JS, Gao RL, Xu B, Qiao SB. [Prognostic value of SYNTAX score on 1 year outcome in patients underwent percutaneous coronary intervention]. Zhonghua Xin Xue Guan Bing Za Zhi. 2018 Apr 24;46(4):267-273. doi: 10.3760/cma.j.issn.0253-3758.2018.04.004. Chinese. |
| 27173037 | Derived | Xu B, Gao R, Yang Y, Cao X, Qin L, Li Y, Li Z, Li X, Lin H, Guo Y, Ma Y, Wang J, Nie S, Xu L, Cao E, Guan C, Stone GW; PANDA III Investigators. Biodegradable Polymer-Based Sirolimus-Eluting Stents With Differing Elution and Absorption Kinetics: The PANDA III Trial. J Am Coll Cardiol. 2016 May 17;67(19):2249-2258. doi: 10.1016/j.jacc.2016.03.475. |
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |