| Name | Class |
|---|---|
| Biotronik Canada Inc | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to evaluate the effectiveness of paclitaxel-coated balloon catheter to prevent restenosis after PTA (percutaneous transluminal angioplasty) of hemodialysis access (HA) in comparison with the uncoated PTA balloon catheter.
In Canada, there are over 20,000 patients with chronic end-stage renal disease (ESRD)on long-term hemodialysis and the number is increasing rapidly.The creation of hemodialysis access (HA) (also called "lifeline" for dialysis patients) has become the most common type of vascular surgery. These HA are frequently complicated by dysfunction after their creation mainly due to neointimal hyperplastic stenosis (> 60% at one year). PTA is an established cornerstone method of treating stenotic lesions because of its minimally invasive percutaneous nature and widespread availability.Although PTA has a high initial success rate,narrowing will often recur in 2-3 months hence requiring further interventions. There are currently no durable therapies for the prevention or treatment of HA dysfunction restenosis after PTA.
Recently drug eluting balloon (DEB) with paclitaxel have repeatedly demonstrated their effectiveness to prevent restenosis due to intimal proliferation in the coronary and peripheral arterial systems. The investigators believe that the DEB with paclitaxel will significantly decrease the HA restenosis rate at the treated site and therefore will improve the management of HA failures.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Paclitaxel Eluting Balloon | Experimental | Paclitaxel Eluting Balloon Angioplasty |
|
| Conventional uncoated balloon | Active Comparator | Percutaneous Transluminal Angioplasty (PTA) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Paclitaxel Eluting Balloon Angioplasty | Device |
|
| |
| Measure | Description | Time Frame |
|---|---|---|
| Late lumen loss (LLL) at 6 months after PTA (percutaneous transluminal angioplasty) | Comparison of the mean LLL (late lumen loss) in patients in the two trial arms (DEB vs plain PTA) evaluated by quantitative angiography at six months after PTA. LLL is defined as the difference between the MLD (minimum lumen diameter) immediately after balloon angioplasty and the MLD at follow-up | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| The angiographic percentage of diameter stenosis and the incidence of angiographic binary restenosis rate (≥50% of the diameter of the reference-vessel segment) | The change in the degree of stenosis (in %) at the intervention site between the measure right after the intervention, and 6 months later and the difference between restenosis rates in the two trial arms at 6 months. | 6 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Éric Therasse, MD | Centre hospitalier de l'Université de Montréal (CHUM) | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hôpital Charles-Lemoyne | Longueuil | Quebec | Canada | |||
| Hôpital Maisonneuve-Rosemont |
Not provided
| ID | Term |
|---|---|
| D017130 | Angioplasty |
| ID | Term |
|---|---|
| D002404 | Catheterization |
| D013812 | Therapeutics |
| D057510 | Endovascular Procedures |
| D014656 | Vascular Surgical Procedures |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Percutaneous Transluminal Angioplasty (PTA) |
| Device |
|
|
| Change of HA flow | Difference between mean HA flow in the two groups (measured at the same times) | Before angioplasty, week 1, month 1or month 3 |
| The rate of HA failure | Time elapsed from the initial intervention (at randomization) to the earliest (if any) of these 3 events: HA thrombosis, HA re-intervention (surgical or endovascular, including creation of a new HA), or CVC (central venous catheter) insertion for dialysis purpose | 3 months |
| Drug eluting balloon safety | Proportion of patients with side effects in the 2 groups. | 3 months |
| Montreal |
| Quebec |
| H1T 2M4 |
| Canada |
| Centre Hospitalier de l'université de Montréal-CHUM | Montreal | Quebec | H2L 4M1 | Canada |
| D013504 |
| Cardiovascular Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
| D019060 | Minimally Invasive Surgical Procedures |
| D008919 | Investigative Techniques |