Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| National Medical Research Council (NMRC), Singapore | OTHER_GOV |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
A prospective randomized trial comparing the efficacy of drug eluting balloon angioplasty versus conventional percutaneous transluminal angioplasty balloon for the treatment of hemodialysis arterio-venous fistula or arterio-venous graft stenoses in reducing late luminal loss and restenosis rates, while prolonging primary and secondary patencies.
Introduction:
Neointimal hyperplasia is the main cause of hemodialysis access [arterio-venous fistula (AVF) or graft (AVG)] dysfunction and thrombosis. Although endovascular techniques like percutaneous transluminal angioplasty (PTA), catheter directed thrombolysis, mechanical thrombectomy or bare metal stenting, may salvage the access, long term patency remains dismal due to recurrent stenosis from neointimal hyperplasia.
Drug Eluting Balloon (DEB) is effective in inhibiting neointimal hyperplasia for treatment of coronary in-stent restenosis since 2006 and more recently in femoropopliteal arteries, reducing restenosis rates and prolonging patency.
Specific Aim:
To determine the efficacy of DEB in reducing restenosis rates and prolonging the patency of AVFs/AVGs compared to PTA.
Hypothesis:
DEB is superior to PTA in reducing late luminal loss and restenosis rates, while prolonging primary and secondary patencies.
Methodology:
Prospective, randomized clinical trial with study population comprising of patients with dysfunctional AVFs/AVGs due to underlying stenoses. The patients will be randomized to receive either DEB or PTA.
The 6-month late luminal loss will be primary endpoint. The secondary endpoints of restenosis rate, primary and secondary patencies, will also be determined.
Major Clinical Significance:
Hemodialysis access failures constitute significant morbidity and costs to patient and healthcare system. Maintaining access patency consumes significant resources and constitutes a significant portion of the work of vascular surgeons, nephrologists and interventional radiologists.
Any strategy that reduces access failure or prolonging access lifespan will be beneficial. If DEB is proven to be superior to PTA, there will be a paradigm shift in management of hemodialysis access failures from restenosis - similar to how DEB has changed practice in managing coronary artery in-stent restenosis.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Conventional PTA only | Active Comparator | Treatment Arm 1- Conventional PTA only The conventional balloon is used and the diameter of the balloon should be the same or oversized by 1mm the diameter of the reference vessel. An inflation device with a pressure gauge is used to inflate up to manufacturers' stated burst pressure. The duration of balloon inflation will be 2 minutes. At the end of the first angioplasty, an AVFistulogram/AVGraftogram will be obtained to document results. If there is residual stenosis of >30%, a repeat angioplasty using the same balloon or another appropriately oversized balloon by 1mm will be used for an additional 2 minutes. A final angiogram will be obtained for documentation. |
|
| Drug Eluting Balloon (DEB) | Experimental | Treatment arm 2 - Conventional Balloon with DEB A Conventional balloon is used to pre-dilate the target lesion. The DEB of a similar diameter to the conventional balloon used is then inflated across the stenosis. An inflation device with a pressure gauge is used to inflate up to manufacturers' stated burst pressure. The duration of balloon inflation will be 1 minute. A final angiogram will be obtained for documentation. The drug coated on the DEB is Paclitaxel. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Conventional PTA | Device | Use of conventional balloon for angioplasty only |
|
| Measure | Description | Time Frame |
|---|---|---|
| Late luminal loss | Late luminal loss is defined as the difference between the minimum lumen diameters after angioplasty and at the end of the 6-month follow-up angiogram. | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Restenosis rate | Restenosis rate is defined as the incidence of stenosis ≥50% of the diameter of the reference vessel segment. | 6 months |
| Primary patency | Primary patency is defined as the interval from balloon angioplasty until the next access thrombosis or repeated intervention to maintain access function, or until access abandonment if no interval intervention. It ends with treatment of a lesion anywhere within the access circuit, from the arterial inflow to the superior vena cava-right atrial junction. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Farah G Irani, MBBS,FRCR | Singapore General Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Singapore General Hospital | Singapore | 169068 | Singapore |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Drug Eluting Balloon (DEB) | Device | Use of DEB after conventional balloon angioplasty |
|
|
| 6 months |
| Primary assisted patency | Primary assisted patency is defined as the interval from balloon angioplasty until access thrombosis or a surgical intervention that excludes the treated lesion from the access circuit. Examples include percutaneous treatments of either restenosis/occlusion of the previously treated lesion or a new arterial or venous outflow stenosis/occlusion (excluding access thrombosis). It ends with percutaneous thrombolysis/thrombectomy or simple surgical thrombectomy. | 6 months |
| Secondary patency | Secondary patency is defined as the interval after balloon angioplasty until the access is surgically declotted, revised or abandoned because of inability to treat the original lesion, choice of surgeon, transplant, loss to follow-up, etc. Examples include thrombolysis and percutaneous thrombectomy, as well as multiple repetitive treatments. | 6 months |
| Anatomic success | Anatomic success is defined as <30% residual stenosis diameter measured immediately after angioplasty. | Immediate post procedure |
| Clinical success | Clinical success is defined as an improvement from baseline in the clinical or hemodynamic parameter (e.g., blood flow, venous pressures) that was the initial indicator of fistula/ graft dysfunction. | Immediate post procedure |
| Procedural success | Procedural success is defined as the combination of anatomic success and clinical success. | Immediate post procedure |
| ID | Term |
|---|---|
| D001164 | Arteriovenous Fistula |
| ID | Term |
|---|---|
| D001165 | Arteriovenous Malformations |
| D054079 | Vascular Malformations |
| D018376 | Cardiovascular Abnormalities |
| D002318 | Cardiovascular Diseases |
| D016157 | Vascular Fistula |
| D014652 | Vascular Diseases |
| D000013 | Congenital Abnormalities |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |
| D005402 | Fistula |
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided