Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Catheter-based renal sympathetic modification has been documented to be effective option for blood pressure control in patients with resistant hypertension, but the safety is still concerned around worldwide. Based on anatomic findings, blocking renal sympathetic nerves at proximity may be enough for successful renal sympathetic modifications. This study was designed to compare the efficacy and safety of full length versus proximal ablation of bilateral renal arteries.
After baseline assessment was completed, patients with resistant hypertension were enrolled, and randomly divided into two groups. This study is going to recruit 40 patients (group 1 VS group 2 = 1:1) with a follow-up duration of one year. Group 1 received ablation from distal to ostial of bilateral renal arteries, group 2 received ablation at proximal of bilateral renal arteries. RDN was performed with saline irrigated catheter. Office and ambulatory blood pressure was measured.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group 1 | Active Comparator | Group 1 received ablation from distal to ostial of bilateral renal arteries |
|
| Group 2 | Experimental | group 2 received ablation at proximal of bilateral renal arteries |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Thermocool®Rcatheter | Device | The full length RDN was performed discretely from distal to proximal by point to point using Thermocool®Rcatheter |
|
| Measure | Description | Time Frame |
|---|---|---|
| Blood pressure | office BP and Ambulatory blood pressure | one year |
| Measure | Description | Time Frame |
|---|---|---|
| ablation-related complications | ablation-related complications such as pseudoaneurysm,renal artery injury | one year |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| 2ndChongqingMU | Chongqing | Chongqing Municipality | 400010 | China |
Not provided
| ID | Term |
|---|---|
| C563514 | Hypertension Resistant to Conventional Therapy |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Thermocool®Rcatheter | Device | The proximity renal denervation was performed discretely at 10-15 mm of proximal renal artery, using Thermocool®Rcatheter |
|