In this pilot study, the first objective is to bench test a novel shear reducing insole and compare it to current standard insoles and shoes. The second objective is to study twenty-seven insensate diabetes patients with pre-ulcerative foot callus to examine for changes in spatial temporal gait including gait initiation, risk of falling, static and dynamic balance, and plantar temperature response to walking and consecutive plantar stress in both footwear conditions.
Device Description: The Dynamic Foot Orthosis (DFO) is designed with a rolling link mechanism at the distal 3rd. It is designed to reduce sliding friction and torque at the metatarsal heads in addition to decreasing compressive forces that is accomplished by the conventional multi-durometer FOs. The relative sliding motion of two compliant surfaces over each other allows some deformation horizontally and lowers frictional resistance. The DFO addresses the friction element by accommodating the normal sliding and rolling motion at the distal 3rd of the foot during gait. Additionally, the DFO has a silicone layer at the metatarsal head and the remainder of the anterior section made of 2 separated orthotic layers that slide over each other. This provides an articulating surface to provide a relative motion between the orthotic segments while transmitting load.
Study Objectives: In this pilot study, the first objective is to bench test a novel shear reducing insole and compare it to current standard insoles and shoes. The second objective is to study twenty-seven insensate diabetes patients with pre-ulcerative foot callus to examine for changes in spatial temporal gait including gait initiation, risk of falling, static and dynamic balance, and plantar temperature response to walking and consecutive plantar stress in both footwear conditions.
Study Design: This is an interventional study. For objective one, changes in compression stiffness and static coefficients of friction will be measured using a force dynamometer in the lab of Professor Albert Shih. A test platform will be built to evaluate the performance of the shear reduction shoe sole design and characteristic of the force, in two directions parallel (shear) and perpendicular to the ground, and the associated deformation under the steady-state and impulse conditions.
For objective two, diabetes patients presenting to the Michigan Orthotics and Prosthetics Center for fabrication and dispensing of diabetic shoes and innersoles will be invited to participate. Twenty-seven insensate diabetes patients with pre-ulcerative foot callus will be enrolled. Patients will wear body worn sensors (LegSys) to measure changes in spatial-temporal gait and static and dynamic balance parameters prior and post usage of the insoles. To reduce the effects of learning from naïve use of novel footwear, the testing sequence between the experimental and standard footwear will be randomized. We will examine increase on foot temperature over 200 steps of continuous walking using the DFO and using standard insoles. We will also examine if the thermal changes are mediated by autonomic neuropathy as measured by sudomotor function. The footwear testing sequence will be randomized and an acclimatization procedure will be followed in an effort to minimize the potential effects of cumulative plantar temperature responses to walking and footwear conditions. We will also examine static balance by measuring center of mass with eyes open and eyes closed condition.
Outcome Measures: For objective one, the primary endpoints will be the compression stiffness and static coefficients of friction. For objective two, plantar foot temperature changes in regions-of-interest in response to walking 200 steps will be measured in each footwear condition and compared to baseline. Other outcome measures include gait analysis, including gait initiation, gait speed, double support time, medial and lateral center of mass displacement, and inter-cycle variability under single and dual task conditions. This will be measured during each footwear condition. Static balance will also be measured in each footwear condition. Using the Romberg's test, we will also assess center of mass displacement and reciprocal hip and ankle motion under eyes open and closed conditions. Sudomotor function will be measured by electrical sweat conductance (ESC), as expressed in microSiemens (µS).
Safety Evaluation: All subjects who sign the informed consent form and are determined to be eligible for treatment will be included in the analysis of safety. Collection, classification and summary analysis of adverse events will be performed.
Duration of Participation: One visit lasting approximately 1 hour.
Duration of Study: One year
Inclusion Criteria: Patients will be included if they have diabetes and have been referred for diabetic shoes. They will also be insensate with pre-ulcerative plantar callus or previous plantar foot ulcer.
Exclusion Criteria: Patients will be excluded if they are unable to independently walk 100 feet, lower extremity prosthesis user, have active cellulitis, foot ulcer, or Charcot foot.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Standard innersole | Active Comparator | Per sequence cross over design. Order of testing innersoles was randomized and each testing condition lasted 15 minutes. The industry standard diabetic innersole will be used as the active comparator |
|
| Diabetic Foot Orthotic | Experimental | The Dynamic Foot Orthosis (DFO) is designed with a rolling link mechanism at the distal 3rd to reduce sliding friction at the metatarsal heads in addition to decreasing compressive forces. The relative sliding motion of two compliant surfaces over each other allows some deformation horizontally and lowers frictional resistance. The DFO addresses the friction element by accommodating the normal sliding and rolling motion at the distal 3rd of the foot during gait. Additionally, the DFO has a silicone layer at the metatarsal head and the remainder of the anterior section made of 2 separated orthotic layers that slide over each other. This provides an articulating surface to provide a relative motion between the orthotic segments while transmitting load. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| diabetic foot orthotic | Device | The Dynamic Foot Orthosis (DFO) is designed with a rolling link mechanism at the distal 3rd to reduce sliding friction at the metatarsal heads in addition to decreasing compressive forces. The relative sliding motion of two compliant surfaces over each other allows some deformation horizontally and lowers frictional resistance. The DFO addresses the friction element by accommodating the normal sliding and rolling motion at the distal 3rd of the foot during gait. Additionally, the DFO has a silicone layer at the metatarsal head and the remainder of the anterior section made of 2 separated orthotic layers that slide over each other. This provides an articulating surface to provide a relative motion between the orthotic segments while transmitting load. |
| Measure | Description | Time Frame |
|---|---|---|
| Plantar Foot Temperature Changes in Regions-of-interest in Response to Walking | Plantar foot temperature changes in regions-of-interest in response to walking 200 steps will be measured in each footwear condition and compared to baseline. | baseline and after 200 steps in each condition, this is a single visit study expected to last one hour |
| Measure | Description | Time Frame |
|---|---|---|
| Gait Initation - Single Task | The number of steps taken to reach steady state walking under single task. Single task means walking without a simultaneous mental task. | during each foot wear condition up to 30 minutes |
| Gait Initiation - Dual Task |
| Measure | Description | Time Frame |
|---|---|---|
| Stride Velocity - Single Task | Stride velocity steady state gait single task. Single task means walking without a simultaneous mental task. | during each foot wear condition up to 30 minutes |
| Sudomotor Function |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| James Wrobel, DPM, MS | UMHS | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Michigan Orthotics and Prosthetics | Ann Arbor | Michigan | 48104-6768 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23567000 | Result | Belmont B, Wang Y, Ammanath P, Wrobel JS, Shih A. An apparatus to quantify anteroposterior and mediolateral shear reduction in shoe insoles. J Diabetes Sci Technol. 2013 Mar 1;7(2):410-9. doi: 10.1177/193229681300700218. | |
| 25107709 | Result | Wrobel JS, Ammanath P, Le T, Luring C, Wensman J, Grewal GS, Najafi B, Pop-Busui R. A novel shear reduction insole effect on the thermal response to walking stress, balance, and gait. J Diabetes Sci Technol. 2014 Nov;8(6):1151-6. doi: 10.1177/1932296814546528. Epub 2014 Aug 7. |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Standard Innersole Followed by DFO | The industry standard diabetic innersole will be used as the active comparator Standard innersole DFO The Dynamic Foot Orthosis (DFO) is designed with a rolling link mechanism at the distal 3rd to reduce sliding friction at the metatarsal heads in addition to decreasing compressive forces. The relative sliding motion of two compliant surfaces over each other allows some deformation horizontally and lowers frictional resistance. The DFO addresses the friction element by accommodating the normal sliding and rolling motion at the distal 3rd of the foot during gait. Additionally, the DFO has a silicone layer at the metatarsal head and the remainder of the anterior section made of 2 separated orthotic layers that slide over each other. This provides an articulating surface to provide a relative motion between the orthotic segments while transmitting load. |
| FG001 | Diabetic Foot Orthotic Followed by Standard Innersole | The Dynamic Foot Orthosis (DFO) is designed with a rolling link mechanism at the distal 3rd to reduce sliding friction at the metatarsal heads in addition to decreasing compressive forces. The relative sliding motion of two compliant surfaces over each other allows some deformation horizontally and lowers frictional resistance. The DFO addresses the friction element by accommodating the normal sliding and rolling motion at the distal 3rd of the foot during gait. Additionally, the DFO has a silicone layer at the metatarsal head and the remainder of the anterior section made of 2 separated orthotic layers that slide over each other. This provides an articulating surface to provide a relative motion between the orthotic segments while transmitting load. The industry standard diabetic innersole will be used as the active comparator Standard innersole |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| First Intervention up to 30 Minutes |
| |||||||||||||
| Second Intervention up to 30 Minutes |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | All Study Participants | The industry standard diabetic innersole will be used as the active comparator Standard innersole The Dynamic Foot Orthosis (DFO) is designed with a rolling link mechanism at the distal 3rd to reduce sliding friction at the metatarsal heads in addition to decreasing compressive forces. The relative sliding motion of two compliant surfaces over each other allows some deformation horizontally and lowers frictional resistance. The DFO addresses the friction element by accommodating the normal sliding and rolling motion at the distal 3rd of the foot during gait. Additionally, the DFO has a silicone layer at the metatarsal head and the remainder of the anterior section made of 2 separated orthotic layers that slide over each other. This provides an articulating surface to provide a relative motion between the orthotic segments while transmitting load. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Plantar Foot Temperature Changes in Regions-of-interest in Response to Walking | Plantar foot temperature changes in regions-of-interest in response to walking 200 steps will be measured in each footwear condition and compared to baseline. | Posted | Mean | Standard Deviation | Absolute change in temperature degrees | baseline and after 200 steps in each condition, this is a single visit study expected to last one hour |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Standard Innersole | The industry standard diabetic innersole will be used as the active comparator Standard innersole |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| James Wrobel, DPM, MS | University of Michigan | 734-647-4940 | jswrobel@med.umich.edu |
Not provided
| ID | Term |
|---|---|
| D017719 | Diabetic Foot |
| ID | Term |
|---|---|
| D003925 | Diabetic Angiopathies |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D016523 | Foot Ulcer |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Standard innersole | Other |
|
The number of steps taken to reach steady state walking under dual task. Dual task used a simultaneous mental task while walking.
| during each foot wear condition up to 30 minutes |
| Stride Velocity - Dual Task | Stride velocity during steady state dual task. Dual task used a simultaneous mental task while walking. | during each foot wear condition up to 30 minutes |
| Double Support Time Single Task | percentage of stride time spent in double support time during gait initiation. Double support time refers to the time spent with both feet on the ground. Single task means walking without a simultaneous mental task. | during each foot where condition up to 30 minutes |
| Double Support Time Dual Task Gait Initiation | percentage of stride time spent in double support time during dual task conditions and during gait initiation. Double support time refers to the time spent with both feet on the ground. Dual task used a simultaneous mental task while walking. | during each foot where condition up to 30 minutes |
| Medial and Lateral Center of Mass Displacement Single Task | Mediolateral (side-to-side) center of mass displacement with displacement in deg2 (degrees squared) under single task gait conditions. Single task means walking without a simultaneous mental task. | under each foot where condition up to 30 minutes |
| Medial and Lateral Center of Mass Displacement Dual Task | Mediolateral (side-to-side) center of mass displacement in deg2 (degrees squared) under dual task gait. Dual task used a simultaneous mental task while walking. | both footwear conditions up to 30 minutes |
| Gait Speed Variability Single Task | Gait speed variability (estimated using coefficient and variation of stride velocity) Single task means walking without a simultaneous mental task. | both footwear conditions up to 30 minutes |
| Gait Speed Variability Dual Task | Gait speed variability (estimated using coefficient and variation of stride velocity) Dual task used a simultaneous mental task while walking. | Both footwear conditions up to thirty minutes |
Sudomotor function will be measured by electrical sweat conductance (ESC), as expressed in microSiemens (µS).
| at baseline, this is a single visit study expected to last one hour |
| NOT COMPLETED |
|
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
|
|
| Secondary | Gait Initation - Single Task | The number of steps taken to reach steady state walking under single task. Single task means walking without a simultaneous mental task. | Posted | Mean | Standard Deviation | Number of steps | during each foot wear condition up to 30 minutes |
|
|
|
| Other Pre-specified | Stride Velocity - Single Task | Stride velocity steady state gait single task. Single task means walking without a simultaneous mental task. | Posted | Mean | Standard Deviation | meters/second | during each foot wear condition up to 30 minutes |
|
|
|
| Other Pre-specified | Sudomotor Function | Sudomotor function will be measured by electrical sweat conductance (ESC), as expressed in microSiemens (µS). | Posted | Mean | Standard Deviation | µS | at baseline, this is a single visit study expected to last one hour |
|
|
|
| Secondary | Gait Initiation - Dual Task | The number of steps taken to reach steady state walking under dual task. Dual task used a simultaneous mental task while walking. | Posted | Mean | Standard Deviation | Number of steps | during each foot wear condition up to 30 minutes |
|
|
|
| Secondary | Stride Velocity - Dual Task | Stride velocity during steady state dual task. Dual task used a simultaneous mental task while walking. | Posted | Mean | Standard Deviation | m/s | during each foot wear condition up to 30 minutes |
|
|
|
| Secondary | Double Support Time Single Task | percentage of stride time spent in double support time during gait initiation. Double support time refers to the time spent with both feet on the ground. Single task means walking without a simultaneous mental task. | Posted | Mean | Standard Deviation | percentage of stride time | during each foot where condition up to 30 minutes |
|
|
|
| Secondary | Double Support Time Dual Task Gait Initiation | percentage of stride time spent in double support time during dual task conditions and during gait initiation. Double support time refers to the time spent with both feet on the ground. Dual task used a simultaneous mental task while walking. | Posted | Mean | Standard Deviation | percentage of stride time | during each foot where condition up to 30 minutes |
|
|
|
| Secondary | Medial and Lateral Center of Mass Displacement Single Task | Mediolateral (side-to-side) center of mass displacement with displacement in deg2 (degrees squared) under single task gait conditions. Single task means walking without a simultaneous mental task. | Posted | Mean | Standard Deviation | deg2 | under each foot where condition up to 30 minutes |
|
|
|
| Secondary | Medial and Lateral Center of Mass Displacement Dual Task | Mediolateral (side-to-side) center of mass displacement in deg2 (degrees squared) under dual task gait. Dual task used a simultaneous mental task while walking. | Posted | Mean | Standard Deviation | deg2 | both footwear conditions up to 30 minutes |
|
|
|
| Secondary | Gait Speed Variability Single Task | Gait speed variability (estimated using coefficient and variation of stride velocity) Single task means walking without a simultaneous mental task. | Posted | Mean | Standard Deviation | percentage of gait | both footwear conditions up to 30 minutes |
|
|
|
| Secondary | Gait Speed Variability Dual Task | Gait speed variability (estimated using coefficient and variation of stride velocity) Dual task used a simultaneous mental task while walking. | Posted | Mean | Standard Deviation | percentage of gait | Both footwear conditions up to thirty minutes |
|
|
|
| 0 |
| 27 |
| 0 |
| 27 |
| EG001 | Diabetic Foot Orthotic | The Dynamic Foot Orthosis (DFO) is designed with a rolling link mechanism at the distal 3rd to reduce sliding friction at the metatarsal heads in addition to decreasing compressive forces. The relative sliding motion of two compliant surfaces over each other allows some deformation horizontally and lowers frictional resistance. The DFO addresses the friction element by accommodating the normal sliding and rolling motion at the distal 3rd of the foot during gait. Additionally, the DFO has a silicone layer at the metatarsal head and the remainder of the anterior section made of 2 separated orthotic layers that slide over each other. This provides an articulating surface to provide a relative motion between the orthotic segments while transmitting load. | 0 | 27 | 0 | 27 |
Not provided
Not provided
| D007871 |
| Leg Ulcer |
| D012883 | Skin Ulcer |
| D012871 | Skin Diseases |
| D017437 | Skin and Connective Tissue Diseases |
| D048909 | Diabetes Complications |
| D003920 | Diabetes Mellitus |
| D004700 | Endocrine System Diseases |
| D003929 | Diabetic Neuropathies |