Introduction: Inhalation therapy has been established as an efficient route to treat asthma exacerbations, but coupled to noninvasive ventilation (NIV) remains quite challenging.
Objectives: The aim of this study were to compare radiaoaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) using vibrating mesh nebulizers (VMN) and jet nebulizer (JN) coupled to noninvasive ventilation (NIV).
Material and methods: The investigators assessed 10 stable moderate to severe asthmatics in a crossover study. Patients was randomly assigned to participate in both phases of the study: Phase 1(NIV+MN) and phase 2(NIV+JN). DTPA-Tc99m with radioactivity of 25 miC was used to inhaler using JN positioned in the circuit using a "T" piece, particle size generation in a five micron range and oxygen flow tritated at eight L/min and MN was positioned in the mask, particle size generation in a one range and connected to electrical energy. NIV was used a bilevel pressure through a face mask attached with straps and pressure adjusted were 12 cmH2O and 5 cmH2O as inspiratory and expiratory pressures, respectively. After, radioactivity counts were performed using a gama camera and regions of interest were delimited. To calculate aerosol mass balance the investigators considered the amount of radioaerosol deposited into the lungs, upper airways, stomach, nebulizer, circuit, inspiratory and expiratory filters, and mask divided for each of these compartments and represented as a percentage.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Control Group | Active Comparator | Noninvasive ventilation + jet nebulizer |
|
| Experimental Group | Experimental | Noninvasive ventilation + vibrating mesh nebulizer |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Noninvasive ventilation | Other | Bilevel positive pressure (BiPAP Synchrony, Respironics®, Murrysville, Pennsylvania, USA) was applied through face mask (Comfort Full 2, Respironics®, Murrysville, Pennsylvania, USA) attached with straps and pressure adjusted were 12 cmH2O of inspiratory pressure and 5 cmH2O of expiratory pressure at the beginning of the procedure (França et al., 2006). |
| Measure | Description | Time Frame |
|---|---|---|
| To compare inhaled dose of radioaerosol into the lungs and determine distribution across horizontal and vertical gradients | Immediately after inhalation, participants sat in a chair with the back positioned in front to the gamma camera (STARCAM 3200 GE, California, USA) to obtain radioactives counts from the posterior thorax during a period of 500 seconds on a matrix of 256 X 256 matrix. After, participants were positioned sitting in front to the gama camera to obtain images from face. Then, the same procedure was performed to analysis deposition in the nebulizer, circuits, inspiratory filter, expiratory filter and face mask. Counts representing stomach were obtained from posterior thorax and corrections for decay of technetium were used to during extrapulmonary measurements. | 10 mouths |
| Measure | Description | Time Frame |
|---|---|---|
| To quantify mass balance of the delivery system and different compartments, including intrapulmonary and extrapulmonary deposition. | The analysis of deposition in pulmonary and extrapulmonary compartments was expressed as a percentage from the count in each compartment to the total radioaerosol mass generated by nebulizers. The inhaled radioaerosol was considered the sum of deposition into the upper airways, lungs and stomach. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Valdecir G Filho | Universidade Federal de Pernambuco | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital das Clínicas de Pernambuco | Recife | Pernambuco | 50670-901 | Brazil |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 19484669 | Result | Brandao DC, Lima VM, Filho VG, Silva TS, Campos TF, Dean E, de Andrade AD. Reversal of bronchial obstruction with bi-level positive airway pressure and nebulization in patients with acute asthma. J Asthma. 2009 May;46(4):356-61. doi: 10.1080/02770900902718829. | |
| 22781558 | Result | Galindo-Filho VC, Brandao DC, Ferreira Rde C, Menezes MJ, Almeida-Filho P, Parreira VF, Silva TN, Rodrigues-Machado Mda G, Dean E, Dornelas de Andrade A. Noninvasive ventilation coupled with nebulization during asthma crises: a randomized controlled trial. Respir Care. 2013 Feb;58(2):241-9. doi: 10.4187/respcare.01371. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001249 | Asthma |
| ID | Term |
|---|---|
| D001982 | Bronchial Diseases |
| D012140 | Respiratory Tract Diseases |
| D008173 | Lung Diseases, Obstructive |
| D008171 | Lung Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D063087 | Noninvasive Ventilation |
| ID | Term |
|---|---|
| D012121 | Respiration, Artificial |
| D058109 | Airway Management |
| D013812 | Therapeutics |
| D012138 | Respiratory Therapy |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Jet nebulizer | Device | Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. JN (Mist yMax, Air Life, Yorba Linda, USA) was positioned in the circuit using a "T" piece, particle size generation in a 5 µm range (according to the manufacturer information) and flow oxygen tritated at 8 L/min. |
|
| The vibrating mesh nebulizer (VMN) | Device | Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. VMN (Aeroneb Solo, Galway, Ireland) was positioned in the mask using an elbow (Elbow Kit, Respironics®, Murrysville, Pennsylvania, USA), particle size generation in a 1 µm and connected to electrical energy. |
|
| 10 mouths |
| 12684289 | Result | Soroksky A, Stav D, Shpirer I. A pilot prospective, randomized, placebo-controlled trial of bilevel positive airway pressure in acute asthmatic attack. Chest. 2003 Apr;123(4):1018-25. doi: 10.1378/chest.123.4.1018. |
| D012130 |
| Respiratory Hypersensitivity |
| D006969 | Hypersensitivity, Immediate |
| D006967 | Hypersensitivity |
| D007154 | Immune System Diseases |