In vivo deposition studies of aerosol administration during noninvasive ventilation are scarce in the current literature.
We assessed 10 normal subjects in a crossover study evaluated by pulmonary scintigraphy aiming to compare radiaoaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) of radiotagged aerosol administered using vibrating mesh nebulizers (VMN) and conventional jet nebulizer (JN) during noninvasive ventilation (NIV).
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| NIV plus jet | Active Comparator | Noninvasive ventilation-NIV plus jet nebulizer |
|
| NIV plus Mesh | Experimental | Noninvasive ventilation- NIV plus Mesh nebulizer |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Mesh nebulizer | Other | VMN (NIVO, Respironics®, Murrysville, Pennsylvania, USA) with an MMAD of 3.0 µm was placed in the elbow adapter at the mask. Inhalation was performed using diethilene triamine penta-acetic technetium (99mTc-DTPA) with radioactivity of 25 millicuries (Nobre et al., 2007). Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and normal saline solution to complete a fill volume of 3 mL. |
| Measure | Description | Time Frame |
|---|---|---|
| Radioaerosol deposition index | Inhalation was performed using diethilene triamine penta-acetic technetium (99mTc-DTPA) with radioactivity of 25 millicuries (Nobre et al., 2007). Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and normal saline solution to complete a fill volume of 3 mL. The JN (Misty Max, Air Life, Yorba Linda, USA) with a particle MMAD of 5 µm (according to the manufacturer information) was positioned in the circuit using a "T" piece placed between the circuit leak and the mask, and operated with oxygen flow at 8 L/min. VMN (NIVO, Respironics®, Murrysville, Pennsylvania, USA) with an MMAD of 3.0 µm was placed in the elbow adapter at the mask. | 4 m |
| Measure | Description | Time Frame |
|---|---|---|
| Radioaerosol mass balance in pulmonary and extrapulmonary compartments | the same procedure was performed to analysis deposition in the nebulizer, circuits, inspiratory filter, expiratory filter and face mask. Counts representing stomach were obtained from posterior thorax and corrections for decay of technetium were used during extrapulmonary measurements. The analysis of deposition in pulmonary and extrapulmonary compartments was expressed as a percentage from the cumulative count in each compartment representing the total radioaerosol mass. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Valdecir C Galindo Filho, PhD | UFPE | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital das Clínicas | Recife | Pernambuco | 50000-000 | Brazil |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 12842604 | Result | Newman SP, Pitcairn GR, Hirst PH, Rankin L. Radionuclide imaging technologies and their use in evaluating asthma drug deposition in the lungs. Adv Drug Deliv Rev. 2003 Jul 18;55(7):851-67. doi: 10.1016/s0169-409x(03)00081-4. | |
| 16713403 | Result | Nobre ME, Lopes F, Cordeiro L, Marinho PE, Silva TN, Amorim C, Cahalin LP, Dornelas de Andrade A. Inspiratory muscle endurance testing: pulmonary ventilation and electromyographic analysis. Respir Physiol Neurobiol. 2007 Jan 15;155(1):41-8. doi: 10.1016/j.resp.2006.04.005. Epub 2006 May 19. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Jet nebulizer | Other | The JN (Misty Max, Air Life, Yorba Linda, USA) with a particle MMAD of 5 µm (according to the manufacturer information) was positioned in the circuit using a "T" piece placed between the circuit leak and the mask, and operated with oxygen flow at 8 L/min. Inhalation was performed using diethilene triamine penta-acetic technetium (99mTc-DTPA) with radioactivity of 25 millicuries (Nobre et al., 2007). Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and normal saline solution to complete a fill volume of 3 mL. |
|
| Noninvasive ventilation-NIV | Other | Bilevel positive airway pressure (BiPAP Synchrony, Respironics®, Murrysville, Pennsylvania, USA) was applied through face mask (Comfort Full 2, Respironics®, Murrysville, Pennsylvania, USA) attached with straps and pressure adjusted to12 cmH2O peak inspiratory pressure and 5 cmH2O of expiratory pressure at the beginning of the procedure. Patients were adapted to use NIV before starting measurements, pressures were titrated before reaching the established levels and just after this period masks were fitted using the straps. They were oriented to use a breathing pattern inspiring deeply and exhaling slowing to avoid ventilator-patient asynchrony. |
|
| 4 m |
| 26106207 | Derived | Galindo-Filho VC, Ramos ME, Rattes CS, Barbosa AK, Brandao DC, Brandao SC, Fink JB, de Andrade AD. Radioaerosol Pulmonary Deposition Using Mesh and Jet Nebulizers During Noninvasive Ventilation in Healthy Subjects. Respir Care. 2015 Sep;60(9):1238-46. doi: 10.4187/respcare.03667. Epub 2015 Jun 23. |