In this study the investigators evaluate the sensitivity of PCC2 (PillCam Colon Capsule 2 (R)) in identifying significant polyps in a CRC (Colo Recatal Cancer) screening program (primary outcome measure).
Each enrolled patient underwent three procedures: colon capsule endoscopy, CT-colonography and optical colonoscopy. In this study the reference standard is represented by the segmental unblinded colonoscopy (the unblinding is based on results of both capsule endoscopy and Ct colonography) The investigators also evaluated the tolerability of PCC2 as compared to optical colonoscopy (OC) and CT-colonography (CTC).
Asymptomatic average risk subjects with positive iFOBT (immunochemical Fecal Occult Blood Test), participating the regional screening program, were offered to undergo PCC2 (PillCam Colon Capsule 2 (R)) followed, 21 days later, by CTC and OC performed on the same day. The number, size and location of significant polyps (>6mm) identified by each procedure were compared with the reference standard (RS), which was represented by the segmental unblinded colonoscopy. The unblinding was based on the integration of CTC and PCC2 results. For the PPC2 the quality of the bowel preparation (adequate/inadequate) and the completeness of the examination (capsule excreted still working or visualization of the anal verge) were also reported. In order to evaluate the tolerability, each subject was asked to identify, among the 3 procedures performed, which was the less tolerated one and which one he would be willing to repeat.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Diagnosis of CRC | Other | All the patients enrolled received all the 3 procedures: capsule colonoscopy; CT-colonography and optical colonoscopy. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Capsule colonoscopy; | Device | All the enrolled patients underwent all the three study procedures; the colon capsule is the intervention under evaluation; the other 2 procedures (Ct colonography and optcal colonoscopy contribute to build the composite reference standard) |
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity of PillCam Colon Capsule 2 (R) in identifying significant colonic polyps | The number, size and location of significant polyps (>6mm) identified by each procedure were compared with the reference standard (RS), which was represented by the segmental unblinded colonoscopy. | participants are followed for about 1 month |
| Measure | Description | Time Frame |
|---|---|---|
| to evaluate the tolerability of PCC2 as compared to optical colonoscopy (OC) and CT-colonography (CTC). | In order to evaluate the tolerability, each subject was asked to identify, among the 3 procedures performed, which was the less tolerated one and which one he would be willing to repeat. | participants are followed for about 1 month |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Giancarlo Spinzi | Gastroenterology Unit; Ospedale Valduce | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ospedale Valduce | Recruiting | Como | 22100 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 24398064 | Derived | Rondonotti E, Borghi C, Mandelli G, Radaelli F, Paggi S, Amato A, Imperiali G, Terreni N, Lenoci N, Terruzzi V, Baccarin A, Martegani A, Spinzi G. Accuracy of capsule colonoscopy and computed tomographic colonography in individuals with positive results from the fecal occult blood test. Clin Gastroenterol Hepatol. 2014 Aug;12(8):1303-10. doi: 10.1016/j.cgh.2013.12.027. Epub 2014 Jan 5. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003110 | Colonic Neoplasms |
| ID | Term |
|---|---|
| D015179 | Colorectal Neoplasms |
| D007414 | Intestinal Neoplasms |
| D005770 | Gastrointestinal Neoplasms |
| D004067 | Digestive System Neoplasms |
Not provided
Not provided
| ID | Term |
|---|---|
| D003113 | Colonoscopy |
| ID | Term |
|---|---|
| D016099 | Endoscopy, Gastrointestinal |
| D016145 | Endoscopy, Digestive System |
| D003938 | Diagnostic Techniques, Digestive System |
| D019937 | Diagnostic Techniques and Procedures |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D004066 | Digestive System Diseases |
| D005767 | Gastrointestinal Diseases |
| D003108 | Colonic Diseases |
| D007410 | Intestinal Diseases |
| D003933 | Diagnosis |
| D004724 | Endoscopy |
| D003949 | Diagnostic Techniques, Surgical |
| D013505 | Digestive System Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
| D019060 | Minimally Invasive Surgical Procedures |