This study was design to establish the effectiveness of PillCam® Platform with the PillCam® COLON 2 capsule as demonstrated by the identification of subjects with polyps as compared to optical colonoscopy.
This multi-center study was designed to evaluate the safety and effectiveness of PillCam Platform with the PillCam COLON 2 capsule as demonstrated by the identification of subjects with polyps, compared to optical colonoscopy.
884 subjects participated in this study. All subjects that were enrolled in this study were indicated and scheduled to undergo colonoscopy based on their age and demographics for screening for polyps.
Each subject was required to follow a bowel preparation regimen and to undergo capsule endoscopy (CE) followed by optical colonoscopy (OC). The optical colonoscopy procedure was scheduled 4-6 weeks after CE procedure to allow for the central readers reading of the PillCam RAPID video.
The colonoscopist was kept blinded to the CE results
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PillCam® COLON 2 procedure | Device | Subjects will undergo a PillCam® COLON 2 procedure which includes ingestion of the PillCam® COLON 2 capsule. PillCam® COLON 2 is a disposable, ingestible capsule that takes video images throughout the digestive system. | ||
| Colonoscopy | Procedure | Subjects will undergo standard Colonoscopy procedure 4-6 weeks after PillCam® COLON 2 procedure. Standard colonoscopy involves placement of a standard endoscope (a thin, flexible plastic tube) into the anus and into the colon, a tiny camera in the endoscope allows the study doctor to see the surface of the colon. |
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity and Specificity of PillCam Platform With the PillCam COLON 2 Capsule in Detecting Patients With Polyps ≥6 mm Where OC Considered as the Gold Standard Reference | Sensitivity and specificity of PillCam Platform with the PillCam COLON 2 capsule in detecting subjects with polyps equal to or larger than 6 mm. For a given polyp, a match between the PillCam Colon 2 Capsule and optical colonoscopy was considered if the polyp size was assessed within plus or minus 50% of the size of the estimate of the OC measurement and the polyp as appearing within the same colon segment or in adjacent segments. The polyp size measurement by optical colonoscopy was used as the reference standard. Sensitivity measures the proportion of actual positives which are correctly identified as such. Specificity measures the proportion of negatives which are correctly identified as such. positive event defined as patients with polyps ≥6 mm detected by OC procedure. | 1 year, same as study duration |
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity and Specificity of PillCam Platform With the PillCam COLON 2 Capsule in Detecting Patients With Polyps ≥10 mm Where OC Considered as the Gold Standard Reference | Sensitivity and specificity of PillCam Platform with the PillCam COLON 2 capsule in detecting subjects with polyps equal to or larger than 6 mm. For a given polyp, a match between the PillCam Colon 2 Capsule and optical colonoscopy was considered if the polyp size was assessed within plus or minus 50% of the size of the estimate of the OC measurement and the polyp as appearing within the same colon segment or in adjacent segments. The polyp size measurement by optical colonoscopy was used as the reference standard. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Douglas Rex, Prof. | Indiana University Hospital, Indianapolis, IN, USA | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Alabama Digestive Disorders Center P.C. | Huntsville | Alabama | 35802 | United States | ||
| Indiana University Hospital |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25620668 | Derived | Rex DK, Adler SN, Aisenberg J, Burch WC Jr, Carretero C, Chowers Y, Fein SA, Fern SE, Fernandez-Urien Sainz I, Fich A, Gal E, Horlander JC Sr, Isaacs KL, Kariv R, Lahat A, Leung WK, Malik PR, Morgan D, Papageorgiou N, Romeo DP, Shah SS, Waterman M. Accuracy of capsule colonoscopy in detecting colorectal polyps in a screening population. Gastroenterology. 2015 May;148(5):948-957.e2. doi: 10.1053/j.gastro.2015.01.025. Epub 2015 Jan 22. |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Colon Capsule Endoscopy, Then Standard Colonoscopy | Capsule endoscopy was ingested following colon preparation without colon insufflation or sedation.The purpose was to detect patients with polyps equal or larger than 6mm. Patients subsequently had standard colonoscopy as "gold standard" comparison |
| Title | Milestones | Reasons Not Completed | |||||
|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 1 year, same as study duration |
| Indianapolis |
| Indiana |
| 46202 |
| United States |
| Louisville Gastroenterology Associates | Louisville | Kentucky | 40217 | United States |
| Specialists in Gastroenterology | St Louis | Missouri | 63141 | United States |
| Research Associates of New York | New York | New York | 10075 | United States |
| UNC Chapel Hill Gastroenterology and Hepatology | Chapel Hill | North Carolina | 27599 | United States |
| Dayton Gstroenterology Inc. | Dayton | Ohio | 45440 | United States |
| Franklin Gastroenterology, PLLC | Franklin | Tennessee | 37067 | United States |
| Gastroenterology Consultants, P.A. | Houston | Texas | 77034 | United States |
| Pasadena Gastroenterology Associates, P.A. | Pasadena | Texas | 77505 | United States |
| Gastroenterology Associates of Tidewater | Chesapeake | Virginia | 23320 | United States |
| Soroka University Medical Center | Beersheba | 84101 | Israel |
| Rambam Medical Center | Haifa | 31096 | Israel |
| Bikur Holim Hospital | Jerusalem | Israel |
| Rabin Medical Center | Petah Tikva | 49100 | Israel |
| The Tel-Aviv Sourasky Medical Center | Tel Aviv | 64239 | Israel |
| The Chaim Sheba Medical Center at Tel-Hashomer | Tel Litwinsky | Israel |
| COMPLETED |
|
| NOT COMPLETED |
|
|
CRC population
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Colon Capsule Endoscopy, Then Standard Colonoscopy | Capsule endoscopy was ingested following colon preparation without colon insufflation or sedation.The purpose was to detect patients with polyps equal or larger than 6mm. Patients subsequently had standard colonoscopy as "gold standard" comparison |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean | Standard Deviation | years |
| ||||||||||||||||||||||
| Sex: Female, Male | Count of Participants | Participants |
| |||||||||||||||||||||||
| Region of Enrollment | Number | participants |
|
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Sensitivity and Specificity of PillCam Platform With the PillCam COLON 2 Capsule in Detecting Patients With Polyps ≥6 mm Where OC Considered as the Gold Standard Reference | Sensitivity and specificity of PillCam Platform with the PillCam COLON 2 capsule in detecting subjects with polyps equal to or larger than 6 mm. For a given polyp, a match between the PillCam Colon 2 Capsule and optical colonoscopy was considered if the polyp size was assessed within plus or minus 50% of the size of the estimate of the OC measurement and the polyp as appearing within the same colon segment or in adjacent segments. The polyp size measurement by optical colonoscopy was used as the reference standard. Sensitivity measures the proportion of actual positives which are correctly identified as such. Specificity measures the proportion of negatives which are correctly identified as such. positive event defined as patients with polyps ≥6 mm detected by OC procedure. | Posted | Number | 95% Confidence Interval | percentage of participants | 1 year, same as study duration |
|
|
| |||||||||||||||||||||||||||||||||
| Secondary | Sensitivity and Specificity of PillCam Platform With the PillCam COLON 2 Capsule in Detecting Patients With Polyps ≥10 mm Where OC Considered as the Gold Standard Reference | Sensitivity and specificity of PillCam Platform with the PillCam COLON 2 capsule in detecting subjects with polyps equal to or larger than 6 mm. For a given polyp, a match between the PillCam Colon 2 Capsule and optical colonoscopy was considered if the polyp size was assessed within plus or minus 50% of the size of the estimate of the OC measurement and the polyp as appearing within the same colon segment or in adjacent segments. The polyp size measurement by optical colonoscopy was used as the reference standard. | Posted | Number | 95% Confidence Interval | percentage of participants | 1 year, same as study duration |
|
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Colon Capsule Endoscopy, Then Standard Colonoscopy | Capsule endoscopy was ingested following colon preparation without colon insufflation or sedation.The purpose was to detect patients with polyps equal or larger than 6mm. Patients subsequently had standard colonoscopy as "gold standard" comparison | 1 | 884 | 110 | 884 |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| abdominal pain related to OC procedure | Gastrointestinal disorders | The event was resolved the following day |
|
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Adverse event related to preperation | Gastrointestinal disorders | adverse events were reported as related to the colon preparation such as vomiting and nausea |
| ||
| Adverse event related to Capsule endoscopy | Gastrointestinal disorders | Three adverse events were reported as related to the capsule procedure and resolved within the same day (i.e., severe gagging reflex, mild vomiting and abdominal cramping) |
| ||
| Adverse event related to Colonoscopy | Gastrointestinal disorders | Eleven adverse events were reported as related to the colonoscopy procedure such as fever, headache, abdominal pain, bloating and nausea |
|
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Ravit Peled | Biostatistics and Data Management Manager | Given Imaging | +972 (4) 909-7894 | 7894 | ravit.peled@givenimaging.com |
| ID | Term |
|---|---|
| D011127 | Polyps |
| ID | Term |
|---|---|
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D003113 | Colonoscopy |
| ID | Term |
|---|---|
| D016099 | Endoscopy, Gastrointestinal |
| D016145 | Endoscopy, Digestive System |
| D003938 | Diagnostic Techniques, Digestive System |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
| D004724 | Endoscopy |
| D003949 | Diagnostic Techniques, Surgical |
| D013505 | Digestive System Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
| D019060 | Minimally Invasive Surgical Procedures |