Widening of the single tibial tunnel following ACL surgery with quadrupled hamstrings autograft may contribute to failure of the graft and/or present technical challenges secondary to bone loss in a revision setting (Getelman, 1999). As such, efforts should be made to minimize the incidence and magnitude of tibial tunnel widening without sacrificing the biomechanical properties of the graft construct. The purpose of this investigation is to examine the tibial tunnel widening relationship between bioabsorbable interference screws composed of poly-L-lactic acid (PLLA) alone and composite bioabsorbable interference screws composed of poly-L-lactic acid embedded with beta tricalcium phosphate (PLLA+TCP) utilized as tibial fixation devices.
Specifically the study has the following objectives: 1) To quantify the extent of tibial tunnel enlargement at 3-, 6- and 12-months post ACL reconstruction with autogenous quadrupled hamstring graft; 2) To determine if the incorporation of beta tricalcium phosphate to the bioabsorbable interference screw alters the observed magnitude of tunnel widening; 3) To hypothesize mechanisms for any observed differences between tibial fixation devices; and 4) To correlate tibial tunnel widening with clinical outcome status. It is hypothesized that the PLLA+TCP bioabsorbable interference screw will not be associated with a reduction in tibial tunnel widening around the implant but rather between the implant and articular surface, compared to the PLLA alone screw. It is also hypothesized that there will be no effect of observed tunnel widening on clinical outcomes or graft failure rates.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| PLLA bioscrew | Active Comparator | poly-L-lactic acid bioscrew |
|
| PLLA+TCP bioscrew | Active Comparator | poly-l-lactic acid with beta tricalcium phosphate bioscrew |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Linvatec PLLA+TCP | Device | Linvatec PLLA+TCP tibial interference screw fixation will be used in ACL reconstruction. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Radiographs | At 3-, 6- and 12-months post-operatively, subjects will undergo radiographic examination of their affected knee (standardized AP and lateral views) for analysis of tibial tunnel parameters. Radiographic analysis will be conducted by a single orthopaedic surgeon/fellow/resident blinded to subject group and clinical examination results. Parameters to be recorded and analyzed according to a standardized method: tibial tunnel diameter (max/min). We will also look for: Evidence of lysis in the tunnel and changes in morphological features of tunnel over time | 12 months post op |
| Measure | Description | Time Frame |
|---|---|---|
| ACL Quality of Life Scores | Completed at 3-, 6- and 12-months post operatively for subjective outcome measure. | 12 months post op |
| Measure | Description | Time Frame |
|---|---|---|
| IKDC Assessment | Range of motion assessment at 3-,6-and 12-months post operatively. | 12 months post op |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Peter B MacDonald, MD FRCS(C) | Pan Am Clinic | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Pan Am Clinic | Winnipeg | Manitoba | R3M 3E4 | Canada |
Not provided
Not provided
Not provided
Not provided
Not provided
| Linvatec PLLA | Device | Linvatec PLLA tibial interference screw fixation will be used in ACL reconstruction. |
|