The number of active electrical cardiac implants such as internal cardioverter defibrillators (ICDs), pacemakers or cardiac contractility modules (CCM) has significantly risen over the last two decades. This has been paralleled by an increase in the number of sources of electromagnetic fields in daily life and occupational circumstances.
To date it remains unclear whether patients are at risk of device failure when being subjected to these fields. There are currently no general guidelines available to help clinicians informing their patients about safety levels and behavior around these electromagnetic fields.
This study aims to identify the thresholds of safe use of these devices and potential failures under worst-case conditions in 50/60 Hz fields (i.e.
power line frequency). Device implanted patients will be exposed to electric, magnetic and combined fields of different intensity at various device programming (e.g. nominal and maximum sensitivity). The results will show whether patients are safe in public or occupational environments, which medical relevant disturbances can occur and if a correlation exists between disturbances and device type or patients physique.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| cardiac pacemaker |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Magnetic and electric field´s impact on the implant | Device | Examination of magnetic and electric field's impact on the implant regarding: stability detection threshold using different strength of magnetic and electric field |
| Measure | Description | Time Frame |
|---|---|---|
| Interference threshold of the device in electromagnetic fields in V/m and/or µT | for every patient during one ambulant visit about 1 hour study examination |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
age between 18 and 80
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Andreas Napp, MD | University Hospital, Aachen | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Universtiy Hospital RWTH Aachen | Aachen | Northrhine-Westfalia | 52074 | Germany |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 24163067 | Derived | Napp A, Joosten S, Stunder D, Knackstedt C, Zink M, Bellmann B, Marx N, Schauerte P, Silny J. Electromagnetic interference with implantable cardioverter-defibrillators at power frequency: an in vivo study. Circulation. 2014 Jan 28;129(4):441-50. doi: 10.1161/CIRCULATIONAHA.113.003081. Epub 2013 Oct 25. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D010808 | Physical Examination |
| ID | Term |
|---|---|
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
blood (serum and plasma) urine
|