Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The conventional total dose of 4 L of polyethylene glycol (PEG) given the day before the procedure is safe and effective. It has been the standard cleansing regimen for the last 25 years. To overcome the difficulty in completing the bowel preparation due to large volume and/or taste, reduced-volume (mixed) bowel preparation of bisacodyl and 2 L of PEG have been shown to provide adequate colon cleansing and better tolerability.
LoVol-esse is a reduced-volume PEG-based bowel preparation to be used in combination with bisacodyl and designed to improve patient tolerability and attitude toward bowel cleansing prior to colonoscopy thanks to the reduced volume and improved taste. The present study is intended to compare the new dosing regimen of the bowel lavage solution given the same day compared with standard PEG formulation (SELG 1000) given the day before colonoscopy.
A polyethylene glycol (PEG) electrolyte lavage solution (PEG-ELS) was originally developed in 1980 by the Fordtran group as isosmotic preparation for minimal water and electrolyte exchange with plasma to ensure safe cleansing of the bowel through a mechanical effect of large-volume lavage. The conventional total dose of 4 L given the day before the procedure is safe and effective and has been the standard cleansing regimen for the last 25 years. To overcome the difficulty in completing the bowel preparation due to large volume and/or taste, reduced-volume (mixed) bowel preparation of bisacodyl and 2 L of PEG-ELS have been shown to provide adequate colon cleansing and better tolerability.
In the last recent years, time of preparation has been demonstrated to be a critical factor for bowel preparation for colonoscopy. Several studies have demonstrated that reducing the time interval between the completion of bowel preparation and the exam improves colon cleansing compared with standard dose regimen of the PEG-electrolyte solution given the day before colonoscopy. At the same time manufacturers have tried to improve the taste and palatability of PEG formulations by adding suitable ingredients such as ascorbic acid or citric acid. LoVol-esse is a reduced-volume PEG-based bowel preparation to be used in combination with bisacodyl and designed to improve patient tolerability and attitude toward bowel cleansing prior to colonoscopy thanks to the reduced volume and improved taste. The present study is intended to compare the new dosing regimen of the bowel lavage solution given the same day compared with standard PEG formulation (SELG 1000) given the day before colonoscopy.
The results of this study will tells us if the last-hour preparation is effective and offers adequate tolerability and compliance to be adopted in clinical practice.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| polyethylene glycol (PEG) | Active Comparator |
| |
| PEG low volume with bisacodyl | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| polyethylene glycol (PEG) | Drug | SELG-ESSE 1000 4 L: 2L THE DAY BEFORE OF COLONOSCOPY AND 2 L THE SAME DAY OF COLONOSCOPY |
|
| Measure | Description | Time Frame |
|---|---|---|
| Evaluation of the overall quality of bowel preparation | Quality of preparation will be graded according to the Ottawa Scale. | 4 months |
| Measure | Description | Time Frame |
|---|---|---|
| safety | incidence and severity of the following GI unexpected adverse events: nausea, abdominal bloating, abdominal pain/cramps on a 5-point Likert scale | 4 months |
| compliance | Proportion of patients able to:
|
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Digestive Endoscopy Unit of Catholic University | Rome | Italy | 00168 | Italy |
Not provided
| ID | Term |
|---|---|
| D003111 | Colonic Polyps |
| D003110 | Colonic Neoplasms |
| D015212 | Inflammatory Bowel Diseases |
| ID | Term |
|---|---|
| D007417 | Intestinal Polyps |
| D011127 | Polyps |
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D011092 | Polyethylene Glycols |
| D001726 | Bisacodyl |
| ID | Term |
|---|---|
| D005026 | Ethylene Glycols |
| D006018 | Glycols |
| D000438 | Alcohols |
| D009930 | Organic Chemicals |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| PEG low volume with bisacodyl | Drug | Lovolesse + Lovoldyl 2L of Lovolesse with 2 or 3 tablets of bisacodyl the day before of colonoscopy or 2L of Lovolesse with 2 or 3 tablets of bisacodyl the same day of colonoscopy |
|
| 4 months |
| D015179 | Colorectal Neoplasms |
| D007414 | Intestinal Neoplasms |
| D005770 | Gastrointestinal Neoplasms |
| D004067 | Digestive System Neoplasms |
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D004066 | Digestive System Diseases |
| D005767 | Gastrointestinal Diseases |
| D003108 | Colonic Diseases |
| D007410 | Intestinal Diseases |
| D005759 | Gastroenteritis |
| D011108 |
| Polymers |
| D046911 | Macromolecular Substances |
| D001697 | Biomedical and Dental Materials |
| D008420 | Manufactured Materials |
| D013676 | Technology, Industry, and Agriculture |
| D003408 | Cresols |
| D010636 | Phenols |
| D001555 | Benzene Derivatives |
| D006841 | Hydrocarbons, Aromatic |
| D006844 | Hydrocarbons, Cyclic |
| D006838 | Hydrocarbons |