Heated humidification in CPAP therapy is often not enough to prevent side effects like dryness of nasal mucosa and xerostomia, especially in cases of mouth breathing or mask leakage. Additionally a higher level of humidification in lower ambient room temperature can lead to condensation and irritating noises. Compliance of affected patients decreases considerably. Regarding this, devices with humidifier and additional heated tubing are developed to automatically regulate optimal humidification and temperature right up to the mask. The efficacy of a system with controlled heated humidification and heated tubing in nasal masks under various conditions like leakage and different pressure levels is object of this study.
Participants will breath 3 hours during daytime with a nasal mask under three different humidity modes (No humidity, controlled heated humidification, controlled heated humidification with heated tubing) with CPAP 8 and 12 mmHg and with and without leakage. The ambient room temperature is controlled with air conditioning. Changes in temperature and humidity is measured inside of the mask with a humidity sensor and recorded. After each phase the participants subjective opinion about humidity and temperature is asked.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| heated humidification | Experimental |
| |
| No Humidification | Experimental |
| |
| Controlled heated Humidification with heated tube | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| RESMed S9 with humidifier H5i and heated tube Climate Line | Device | At stable ambient room temperature and different CPAP pressure levels, 8 and 12 cmH2O, with and without additional leakage, humidity and temperature is measured inside of a patients nasal mask. Controlled heated humidification with heated tubing (Climate Line). |
| Measure | Description | Time Frame |
|---|---|---|
| Humidity differences | Changes of humidity and temperature under different conditions (e.g. with and without humidifier, leakage, pressure changes) measured breath by breath with humditiy sensor inside of a nasal mask. | 3 hours per patient |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Karl Heinz Ruehle, MD | Institut für Pneumologie Hagen Ambrock eV | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Helios Klinik Hagen Ambrock | Hagen | North Rhine-Westphalia | 58091 | Germany |
Not provided
| ID | Term |
|---|---|
| D020181 | Sleep Apnea, Obstructive |
| ID | Term |
|---|---|
| D012891 | Sleep Apnea Syndromes |
| D001049 | Apnea |
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D045422 | Continuous Positive Airway Pressure |
| D000068998 | Humidifiers |
| ID | Term |
|---|---|
| D011175 | Positive-Pressure Respiration |
| D012121 | Respiration, Artificial |
| D058109 | Airway Management |
| D013812 | Therapeutics |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| CPAP without humidification | Device | At stable ambient room temperature and different CPAP pressure levels, 8 and 12 cmH2O, with and without additional leakage, humidity and temperature is measured inside of a patients nasal mask. Without any humidification. |
|
|
| CPAP with heated humidification | Device | At stable ambient room temperature and different CPAP pressure levels, 8 and 12 cmH2O, with and without additional leakage, humidity and temperature is measured inside of a patients nasal mask. With controlled heated humidification and standard tubing. |
|
|
| D020919 |
| Sleep Disorders, Intrinsic |
| D020920 | Dyssomnias |
| D012893 | Sleep Wake Disorders |
| D009422 | Nervous System Diseases |
| D012138 |
| Respiratory Therapy |
| D004864 | Equipment and Supplies |
| D006794 | Household Articles |
| D013676 | Technology, Industry, and Agriculture |