The purpose of this study is to reconstruct a 12-lead electrocardiogram (ECG) from intracardiac (IC) electrograms (EGM) obtained from defibrillator devices (ICD). The purpose of such a reconstruction is to allow the use of IC EGM for diagnosis of clinical conditions for which ECG have historically been used, and to test the feasibility of a reconstruction technique for the standard 12-lead or extended electrocardiogram from electrical potentials obtained from inside a patient.
Reconstructing a 12-lead surface ECG from intracardiac EGM vectors of patients implanted with defibrillators can be of great value. It allows implantable devices that have thus far been used exclusively for arrhythmia detection and treatment, to be used for diagnostic purposes in similar ways as the ECG. The advantage of the reconstruction process is that it provides real-time continuous monitoring, which can be used for multiple purposes, including but not limited to:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Defibrillator | The subject population will be obtained by approaching the Principal and Co- Investigators' patients who have been referred for ICD implantation or who already have an ICD. This population ranges in age from 18 years on, and includes both males and females. A maximum of 50 subjects will be enrolled in this study. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| CT scan of the chest without contrast | Radiation | Patients consenting to participate in the study may also undergo a baseline CT scan of the cest without contrast to allow for the geometrical characterization of their intracardiac electrodes from the ICD system in relation to the position of the 12-lead surface ECG electrodes which would be applied to the chest prior to the CT scan. This scan involves a small amount of radiation, a dose of approximately 1 rem. For comparison, radiation workers are permitted, by federal regulation, a maximum annual radiation exposure of 20 rems to the most sensitive organs of their body. |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Subjects will be identified by their cardiologist who is also an investigator on this study at the time they are evaluated for an ICD implantation. Once it has been determined during the course of the patient's regular clinical care that he or she requires an ICD, they will be approached for enrollment into the study by the physician investigator and the clinical research coordinator.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Samir F Saba, MD | University of Pittsburgh | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| UPMC Presbyterian | Pittsburgh | Pennsylvania | 15213 | United States | ||
| UPMC Shadyside |
Not provided
| ID | Term |
|---|---|
| D003287 | Contrast Media |
| ID | Term |
|---|---|
| D064907 | Diagnostic Uses of Chemicals |
| D020228 | Pharmacologic Actions |
| D020164 | Chemical Actions and Uses |
| D020313 | Specialty Uses of Chemicals |
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Pittsburgh |
| Pennsylvania |
| 15232 |
| United States |