Researchers are trying to determine if heart injury occurs in patients with a cardiac implantable electronic device (CIED) who undergo a defibrillation threshold testing (DFT) procedure.
CIED devices that deliver defibrillation can provide life-saving therapy to patients who have cardiac conditions that make them prone to develop a serious arrhythmia. Currently, there are two main CIED devices that deliver defibrillation therapy - transvenous internal cardioverter-defibrillator (ICD) and subcutaneous ICD. Conventional wisdom indicates that defibrillation causes myocardial injury. However, some studies including one by the present investigators have reported that external direct current cardioversion does not result in myocardial injury. There have been studies showing that ICD shocks results in myocardial injury. The concern with previous studies using transvenous ICDs is that the measurement of injury was done during DFT testing at the time of ICD implantation or when the patient came into hospital after an ICD shock. The confounder with DFT testing is that myocardial injury could have occurred during ICD implantation when the lead is screwed into the myocardium rather than during the testing. With hospitalization, the precipitating event that caused the arrhythmia stimulating the ICD discharge (e.g. an acute coronary syndrome) might also be the cause of myocardial injury. We plan to eliminate these confounders by recruiting patients who are undergoing a DFT procedure electively, remote from their ICD implantation date or clinical events.
In terms of the subcutaneous ICD implantation (in which the leads are not screwed into the myocardium), there is little data about myocardial injury when a shock is delivered. The investigators will attempt to determine if subcutaneous ICD shocks cause myocardial injury by assessing their troponin levels at the time DFT is performed during implantation.
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Myocardial injury | Changes in the high sensitivity cardiac troponin T (hs-cTnT) or troponin I (hs-cTnI) assay | Baseline, approximately 6-24 hours after DFT procedure |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Adult males and females age 18 and above who have a cardiac implantable electronic device (CIED) or about to receive a CIED, and scheduled to undergo a defibrillation threshold testing (DFT).
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Allan S Jaffe, MD | Mayo Clinic | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mayo Clinic | Rochester | Minnesota | 55905 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Serum or plasma samples remaining after initial analysis will be frozen and stored at -80 degrees Celsius for 120 months (10 years). These samples may be used if there are new and more sensitive biomarkers of myocardial injury that become available.