This is a pilot study to compare systemic concentrations of cobalt and chromium in patients that have previously undergone total hip arthroplasties with ceramic on metal and metal on metal bearing surfaces.
This is a pilot study to compare systemic concentrations of cobalt and chromium in patients that have previously undergone total hip arthroplasties with ceramic on metal and metal on metal bearing surfaces. Secondary goals include an assessment of osteolysis on radiographs, potential long term analysis of implant survivability, and cancer rates in the two patient populations.
Increased metal ion production has been documented in metal-on-metal arthroplasty articulations. There are several concerns over metal ion production. First, even though there is a decreased histiocytic response to metallic debris, a dose dependent cytotoxic response with Interleukin 6, Prostaglandin E2, and Tumor Necrosis Factor alpha persists and may cause osteolysis in the long term. Second, increased levels of cobalt, chromium and nickel has been shown to correlate with increased cancer rates in several animal models, and the carcinogenic risk in humans has not been fully elucidated as yet. Third, hypersensitivity reactions to metal ion develop in up to 25% of these patients, and 60% of patients with poorly functioning hip.
Ceramic on metal avoids many of these problems due to the improved wear characteristics. If the level of metal ion production is significantly reduced and the implant survivability is proven in long term studies, this articulation may become the preferred method.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Metal-on-Metal Articulations | Subjects will be people who have had metal-on-metal total hip arthroplasties |
| |
| Ceramic-on-Metal Articulations | Subjects will be people who have had ceramic-on-metal total hip arthroplasties |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Blood draw | Biological | Subjects will give blood for analysis of metal ion concentrations |
|
| Measure | Description | Time Frame |
|---|---|---|
| metal ion concentration in urine | 1 year post-op |
| Measure | Description | Time Frame |
|---|---|---|
| metal ion concentration in blood | 1 year post-op |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Subjects enrolled will have already undergone a total hip arthroplasty with either a metal-on-metal articulation, or a ceramic-on-metal articulation.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Daniel Grande, Ph.D. | Feinstein Institute for Medical Research | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Feinstein Institute for Medical Research | Manhasset | New York | 11030 | United States |
Not provided
| ID | Term |
|---|---|
| D010014 | Osteolysis |
| ID | Term |
|---|---|
| D001862 | Bone Resorption |
| D001847 | Bone Diseases |
| D009140 | Musculoskeletal Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D001800 | Blood Specimen Collection |
| ID | Term |
|---|---|
| D013048 | Specimen Handling |
| D019411 | Clinical Laboratory Techniques |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
| X-Ray of Hip | Radiation | Subject will have x-ray of hip to assessment of osteolysis |
|
| D011677 | Punctures |
| D013514 | Surgical Procedures, Operative |
| D008919 | Investigative Techniques |