The objective of this study is to compare serum chromium and cobalt levels of patients who have undergone metal on metal total hip arthroplasty. It is unknown if the presence of bilateral well-functioning large-head metal-on-metal (MOM) total hip arthroplasties (THAs) leads to higher serum metal ion concentrations than unilateral MOM THA. Elevated levels (chromium, 17 μg/L; cobalt, 19 μg/L) have been associated with poorly functioning MOM THA with metallosis. Fourteen patients having undergone bilateral and 25 patients having undergone unilateral large-head primary MOM THA were compared. Harris Hip Scores, University of California Los Angeles activity scores, radiographs, serum creatinine, and serum cobalt and chromium levels were obtained.
The objective of this study is to compare serum chromium and cobalt levels of patients who have undergone metal on metal total hip arthroplasty.
The effect of the presence of bilateral large-head MOM THA on circulating metal ions levels has not been thoroughly studied. Metal ion levels in patients with unilateral MOM vs bilateral MOM resurfacing and small-head THA have been reported; however, to the investigators knowledge, no study has investigated the differences in serum metal ion levels in unilateral vs bilateral largehead (≥38 mm) MOM THA. The objective of this study was to compare serum cobalt and chromium levels in patients who have undergone unilateral vs bilateral large-head MOM THA to better understand the effect of the presence of bilateral implants on circulating metal ion levels. The investigators believe that further understanding baseline levels in well-functioning MOM THA will increase the clinical utility of checking serum metal ion levels in the workup of the painful MOM THA. The investigators hypothesis was that serum metal ion levels in patients with well-functioning bilateral large-head MOM THA would be higher than levels in patients with well functioning unilateral large-head MOM THA, but these levels would not approach those seen with metallosis.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Unilateral or bilateral large head metal on metal primary total hip arthroplasty |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Serum Metal Ion Concentrations | 1 year |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Two groups were identified: the first group having undergone unilateral large-head (≥38 mm) primary MOM THA and the second having undergone bilateral large-head primary MOM THA. Patients were at least 18 years old, were at least 1 year out from their index procedure, and had well-positioned components.
Patients in both cohorts had cementless modular titanium alloy proximally porous-coated, tapered femoral stems (Biomet Taperloc or Bi-Metric; Biomet, Warsaw, Ind).
All surgeries were done between the years of 2003 and 2009.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Christopher Peters, MD | University of Utah Orthopaedic Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Utah Orthopaedic Center | Salt Lake City | Utah | 84108 | United States |
Not provided
Not provided
Not provided
Not provided
Blood will be drawn for analysis.