A Randomized Comparison of a Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) With a Zotarolimus-Eluting Stent (EndeavorTm, Medtronic) for Percutaneous Coronary Intervention
Objectives: The purpose of this study is to compare the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) with a Zotarolimus-Eluting Stent (EndeavorTm, Medtronic) in a non-inferiority trial.
Design: Prospective, multi-center, randomized, non-inferiority trial to be conducted at 3 Swiss interventional cardiology centers. Patients will be randomized in a single-blind fashion (1:1 randomization) to either the Titanium-Nitride-Oxide Coated Stent (Helistent Titan2, Hexacath) or the Zotarolimus-Eluting Stent (EndeavorTm, Medtronic).
Study Population: Patients with symptomatic coronary artery disease including patients with chronic stable angina, silent ischemia, unstable angina, and non-ST elevation myocardial infarction, who qualify for percutaneous coronary interventions
Antiplatelet Therapy: Aspirin 100 mg qd indefinitely; Clopidogrel 75 mg qd for 3 months
Enrollment: A total of 300 patients will be enrolled
All patients will undergo repeat angiography at 6-8 months.
All patients will be followed for up to 5 years.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Titanium Nitride Oxide Coated Stent | Active Comparator | Stent |
|
| Zotarohlimus Eluting Stent | Active Comparator | Stent |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Helistent Titan2 (Titanium coated stent) | Device | Titan2 |
| |
| Measure | Description | Time Frame |
|---|---|---|
| In-stent late luminal loss | 6-8 months after stent implantation |
| Measure | Description | Time Frame |
|---|---|---|
| TLR, TVR, Death or MI, CV death or MI, CV death, Death, MI, Stent thrombosis, Stenosis, Restenosis | 30 days, 6-8 months, 1, 2, 3, 4 and 5 years |
Not provided
Inclusion Criteria:
The following patients are eligible for inclusion
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Stephan Windecker, MD | Department of Cardiology, University Hospital Bern, Bern, Switzerland | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Cardiology, University Hospital Bern | Bern | 3010 | Switzerland |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 15883209 | Background | Windecker S, Simon R, Lins M, Klauss V, Eberli FR, Roffi M, Pedrazzini G, Moccetti T, Wenaweser P, Togni M, Tuller D, Zbinden R, Seiler C, Mehilli J, Kastrati A, Meier B, Hess OM. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization: the TiNOX trial. Circulation. 2005 May 24;111(20):2617-22. doi: 10.1161/CIRCULATIONAHA.104.486647. Epub 2005 May 9. | |
| 11514381 |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| ID | Term |
|---|---|
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D014652 | Vascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| EndeavorTM (Zotarolimus-Eluting Stent) |
| Device |
Endeavor |
|
| Background |
| Windecker S, Mayer I, De Pasquale G, Maier W, Dirsch O, De Groot P, Wu YP, Noll G, Leskosek B, Meier B, Hess OM; Working Group on Novel Surface Coating of Biomedical Devices (SCOL). Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation. 2001 Aug 21;104(8):928-33. doi: 10.1161/hc3401.093146. |
| 25572026 | Derived | Pilgrim T, Raber L, Limacher A, Wenaweser P, Cook S, Stauffer JC, Garachemani A, Moschovitis A, Meier B, Juni P, Windecker S. Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation. EuroIntervention. 2015 Mar;10(11):1284-7. doi: 10.4244/EIJY15M01_04. |
| 21700254 | Derived | Pilgrim T, Raber L, Limacher A, Loffel L, Wenaweser P, Cook S, Stauffer JC, Togni M, Vogel R, Garachemani A, Moschovitis A, Khattab AA, Seiler C, Meier B, Juni P, Windecker S. Comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularization a randomized controlled trial. JACC Cardiovasc Interv. 2011 Jun;4(6):672-82. doi: 10.1016/j.jcin.2011.02.017. |