Prospective, open-labeled First in Man Clinical Investigation enrolling patients with visually estimated nominal vessel diameter of 3.0 mm receiving a single 3.0 x 12 mm or 3.0 x 18 mm BVS EECSS containing 98 microgramme per cm² of surface area.
Single patient Cohort of 30.
Pipeline products. Currently in development at Abbott Vascular. Not available for sale.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Bioabsorbable Vascular Solutions (BVS) Everolimus Eluting Coronary Stent System |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Bioabsorbable Everolimus Eluting Coronary Stent | Device | Bioabsorbable drug eluting stent implantation stent in the treatment of coronary artery disease |
|
| Measure | Description | Time Frame |
|---|---|---|
| Ischemia Driven MACE | at 30, 180, 270 days, and 1, 2, 3, 4, 5 years; | |
| Ischemia driven Target Vessel Failure (TVF) | at 30, 180, 270 days, and 1, 2, 3, 4, 5 years; | |
| Acute success (clinical device and clinical procedure) | Acute | |
| Ischemia Driven Target Lesion Revascularization (TLR) | at 30, 180, 270 days and 1, 2, 3, 4, 5 years; | |
| Ischemia Driven Target Vessel Revascularization (TVR) | at 30, 180, 270 days and 1, 2, 3, 4, 5 years |
| Measure | Description | Time Frame |
|---|---|---|
| In-stent Late Loss(LL) | at 180 days and 2 years | |
| In-segment LL | at 180 days and 2 years | |
| Proximal LL (proximal defined as within 5 mm of tissue proximal to stent placement) |
Not provided
Inclusion Criteria:
Target lesion must be located in a native epicardial vessel with visually estimated nominal vessel diameter of 3.0 mm
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients with coronary artery disease
Not provided
| Name | Affiliation | Role |
|---|---|---|
| John Ormiston, MD | Auckland City Hospital | Principal Investigator |
| Patrick Serruys, MD | Erasmus University Thorax Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Skejby Sygehus | Aarhus | Denmark | ||||
| Erasmus University Thorax Center |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17139655 | Background | Ormiston JA, Webster MW, Armstrong G. First-in-human implantation of a fully bioabsorbable drug-eluting stent: the BVS poly-L-lactic acid everolimus-eluting coronary stent. Catheter Cardiovasc Interv. 2007 Jan;69(1):128-31. doi: 10.1002/ccd.20895. | |
| 17300400 | Background | TCT Daily: ABSORB: bioabsorbable coronary stents successfully and safely deployed. J Interv Cardiol. 2007 Feb;20(1):36-7. doi: 10.1111/j.1540-8183.2007.00235.x. No abstract available. |
Not provided
Not provided
Not provided
Not provided
Not provided
| at 180 days and 2 years |
| Distal LL (distal defined as within 5 mm of tissue distal to stent placement) | at 180 days and 2 years |
| In-stent and in-segment Angiographic Binary Restenosis (ABR) rate | at 180 days and 2 years |
| In-stent % Volume Obstruction (VO) | at 180 days and 2 years |
| Persisting incomplete apposition, late incomplete apposition, aneurysm, thrombus, persisting dissection | at 180 days and 2 years |
| Rotterdam |
| Netherlands |
| Auckland City Hospital | Auckland | New Zealand |
| University Hospital | Krakow | Poland |
| 17503509 | Result | Tanimoto S, Serruys PW, Thuesen L, Dudek D, de Bruyne B, Chevalier B, Ormiston JA. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials. Catheter Cardiovasc Interv. 2007 Oct 1;70(4):515-23. doi: 10.1002/ccd.21136. |
| 18342684 | Result | Ormiston JA, Serruys PW, Regar E, Dudek D, Thuesen L, Webster MW, Onuma Y, Garcia-Garcia HM, McGreevy R, Veldhof S. A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial. Lancet. 2008 Mar 15;371(9616):899-907. doi: 10.1016/S0140-6736(08)60415-8. |
| 19286089 | Result | Serruys PW, Ormiston JA, Onuma Y, Regar E, Gonzalo N, Garcia-Garcia HM, Nieman K, Bruining N, Dorange C, Miquel-Hebert K, Veldhof S, Webster M, Thuesen L, Dudek D. A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods. Lancet. 2009 Mar 14;373(9667):897-910. doi: 10.1016/S0140-6736(09)60325-1. |
| 19284065 | Result | Garcia-Garcia HM, Gonzalo N, Pawar R, Kukreja N, Dudek D, Thuesen L, Ormiston JA, Regar E, Serruys PW. Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis. A substudy of the ABSORB clinical trial. EuroIntervention. 2009 Jan;4(4):443-8. doi: 10.4244/eijv4i4a77. |
| 18992650 | Result | Tanimoto S, Bruining N, van Domburg RT, Rotger D, Radeva P, Ligthart JM, Serruys PW. Late stent recoil of the bioabsorbable everolimus-eluting coronary stent and its relationship with plaque morphology. J Am Coll Cardiol. 2008 Nov 11;52(20):1616-20. doi: 10.1016/j.jacc.2008.08.024. |
| 19110796 | Result | Bruining N, Tanimoto S, Otsuka M, Weustink A, Ligthart J, de Winter S, van Mieghem C, Nieman K, de Feyter PJ, van Domburg RT, Serruys PW. Quantitative multi-modality imaging analysis of a bioabsorbable poly-L-lactic acid stent design in the acute phase: a comparison between 2- and 3D-QCA, QCU and QMSCT-CA. EuroIntervention. 2008 Aug;4(2):285-91. doi: 10.4244/eijv4i2a49. |
| 20031723 | Result | Ormiston JA, Serruys PW. Bioabsorbable coronary stents. Circ Cardiovasc Interv. 2009 Jun;2(3):255-60. doi: 10.1161/CIRCINTERVENTIONS.109.859173. No abstract available. |
| 18679382 | Result | Macaya C, Moreno R. Bioabsorbable drug-eluting stents: the future of coronary angioplasty? Nat Clin Pract Cardiovasc Med. 2008 Oct;5(10):598-9. doi: 10.1038/ncpcardio1306. Epub 2008 Aug 5. |
| 22100687 | Result | Onuma Y, Piazza N, Ormiston JA, Serruys PW. Everolimus-eluting bioabsorbable stent--Abbot Vascular programme. EuroIntervention. 2009 Dec 15;5 Suppl F:F98-F102. doi: 10.4244/EIJV5IFA17. No abstract available. |
| 22100671 | Result | Oberhauser JP, Hossainy S, Rapoza RJ. Design principles and performance of bioresorbable polymeric vascular scaffolds. EuroIntervention. 2009 Dec 15;5 Suppl F:F15-22. doi: 10.4244/EIJV5IFA3. |
| 20975003 | Result | Onuma Y, Serruys PW, Perkins LE, Okamura T, Gonzalo N, Garcia-Garcia HM, Regar E, Kamberi M, Powers JC, Rapoza R, van Beusekom H, van der Giessen W, Virmani R. Intracoronary optical coherence tomography and histology at 1 month and 2, 3, and 4 years after implantation of everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model: an attempt to decipher the human optical coherence tomography images in the ABSORB trial. Circulation. 2010 Nov 30;122(22):2288-300. doi: 10.1161/CIRCULATIONAHA.109.921528. Epub 2010 Oct 25. |
| 24156961 | Derived | Onuma Y, Dudek D, Thuesen L, Webster M, Nieman K, Garcia-Garcia HM, Ormiston JA, Serruys PW. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB cohort A trial. JACC Cardiovasc Interv. 2013 Oct;6(10):999-1009. doi: 10.1016/j.jcin.2013.05.017. |
| 22531596 | Derived | Brugaletta S, Gogas BD, Garcia-Garcia HM, Farooq V, Girasis C, Heo JH, van Geuns RJ, de Bruyne B, Dudek D, Koolen J, Smits P, Veldhof S, Rapoza R, Onuma Y, Ormiston J, Serruys PW. Vascular compliance changes of the coronary vessel wall after bioresorbable vascular scaffold implantation in the treated and adjacent segments. Circ J. 2012;76(7):1616-23. doi: 10.1253/circj.cj-11-1416. Epub 2012 Apr 24. |
| 21959320 | Derived | Dudek D, Onuma Y, Ormiston JA, Thuesen L, Miquel-Hebert K, Serruys PW. Four-year clinical follow-up of the ABSORB everolimus-eluting bioresorbable vascular scaffold in patients with de novo coronary artery disease: the ABSORB trial. EuroIntervention. 2012 Jan;7(9):1060-1. doi: 10.4244/EIJV7I9A168. |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D003324 | Coronary Artery Disease |
| D023903 | Coronary Restenosis |
| D014652 | Vascular Diseases |
| D017202 | Myocardial Ischemia |
| D023921 | Coronary Stenosis |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D001161 | Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
Not provided
Not provided