Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to investigate real time 3-D ultrasound imaging of the brain for the diagnosis and evaluation of stroke.
The objective of this proposal is to extend our previous advances to investigate real time 3-D ultrasound imaging of the brain for the diagnosis and evaluation of stroke. Over the last decade, with the availability of color flow Doppler combined with effective ultrasound contrast agents, a renaissance has occurred in transcranial sonography as a low cost, bedside method for evaluation and management of patients with cerebrovascular disease in spite of the image degrading properties of the skull. Our hypothesis is that we can combine new generations of 2D array transducers with ultrasound contrast agents and phase aberration correction to enable real time 3D ultrasound imaging and 3D color flow Doppler of the brain with a factor of 10 improvement in spatial resolution compared to conventional transcranial sonography for improved diagnosis and evaluation of stroke.
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 3-D ultrasound scanner | Device | The availability of color flow Doppler combined with effective ultrasound contrast agents in transcranial sonography serves as a low cost, bedside method for evaluation and management of patients with cerebrovascular disease in spite of the image degrading properties of the skull. | ||
| Perflutren Protein-Type A Microspheres for injection | Drug | Activated DEFINITY® (Perflutren Lipid Microsphere) Injectable Suspension is indicated for use in patients with suboptimal echocardiograms to opacify the left ventricular chamber and to improve the delineation of the left ventricular endocardial border.Bolus: The recommended dose for activated DEFINITY® is 10 microliters (μL)/kg of the activated product by intravenous bolus injection within 30-60 seconds, followed by a 10 mL saline flush. If necessary, a second 10 microliters (μL)/kg dose followed by a second 10 mL saline flush may be administered 30 minutes after the first injection to prolong contrast enhancement. Infusion: The recommended dose for activated DEFINITY® is via an IV infusion of 1.3 mL added to 50 mL of preservative-free saline. The rate of infusion should be initiated at 4.0 mL/minute, but titrated as necessary to achieve optimal image enhancement, not to exceed 10 mL/minute. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Phase aberration correction of skull bone | This study will look to improve adaptive signal processing techniques for phase aberration correction of the skull while incorporating ultrasound contrast agent to increase signal to noise ratio in an ultrasound B-scan system with high speed RF data acquisition and 2-D arrays.In addition,we hope to develop adaptive transcranial real time 3D ultrasound and real time 3D color flow Doppler scanning of the brain incorporating ultrasound contrast agent to increase signal to noise ratio. A clinical evaluation of adaptive transcranial ultrasound imaging of the brain with phase aberration correction and ultrasound contrast agent will be conducted. | 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Daniel T Laskowitz, MD | Duke UMC | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Duke University Medical Center | Durham | North Carolina | 27710 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21693401 | Result | Lindsey BD, Light ED, Nicoletto HA, Bennett ER, Laskowitz DT, Smith SW. The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Jun;58(6):1189-202. doi: 10.1109/TUFFC.2011.1929. | |
| 18395321 | Result |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D020521 | Stroke |
| D019586 | Intracranial Hypertension |
| ID | Term |
|---|---|
| D002561 | Cerebrovascular Disorders |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D007267 | Injections |
| C042852 | perflutren |
| ID | Term |
|---|---|
| D004333 | Drug Administration Routes |
| D004358 | Drug Therapy |
| D013812 | Therapeutics |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Ivancevich NM, Pinton GF, Nicoletto HA, Bennett E, Laskowitz DT, Smith SW. Real-time 3-D contrast-enhanced transcranial ultrasound and aberration correction. Ultrasound Med Biol. 2008 Sep;34(9):1387-95. doi: 10.1016/j.ultrasmedbio.2008.01.015. Epub 2008 Apr 18. |
| 18947918 | Result | Smith SW, Ivancevich NM, Lindsey BD, Whitman J, Light E, Fronheiser M, Nicoletto HA, Laskowitz DT. The ultrasound brain helmet: feasibility study of multiple simultaneous 3D scans of cerebral vasculature. Ultrasound Med Biol. 2009 Feb;35(2):329-38. doi: 10.1016/j.ultrasmedbio.2008.08.016. Epub 2008 Oct 23. |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |