The Relationship Between Fetal Health Locus of Control Perceptions, Anxiety Levels, and Fetal Cardiotocography Parameters in High-Risk Pregnant Women
The Relationship Between Fetal Health Locus of Control Perceptions, Anxiety Levels, and Fetal Cardiotocography Parameters in High-Risk Pregnant Women
This prospective observational cross-sectional study aims to evaluate the relationships among fetal health locus of control (FHLC) perceptions, maternal anxiety levels, and fetal cardiotocography parameters in high-risk pregnant women. Pregnant women at 32 weeks of gestation or later who undergo routine non-stress testing (NST) at the Perinatology Outpatient Clinic will be invited to participate. On the same day as the routine NST, participants will complete the Fetal Health Locus of Control Scale and the Beck Anxiety Inventory. Associations between FHLC dimensions, maternal anxiety levels, and NST parameters, including baseline fetal heart rate, number of accelerations, reactivity, and presence of decelerations, will be evaluated.
Inclusion Criteria:
Exclusion Criteria:
dcek2000@yahoo.com+905353475411
Fetal health locus of control reflects pregnant women's beliefs regarding the factors that determine the health of their unborn child. These beliefs may influence health-related behaviors during pregnancy. Maternal anxiety may also affect fetal heart rate regulation through autonomic and neuroendocrine mechanisms.
This study will prospectively evaluate high-risk pregnant women at 32 weeks of gestation or later who are undergoing routine non-stress testing at the Perinatology Outpatient Clinic. After written informed consent is obtained, participants will complete the Fetal Health Locus of Control Scale and the Beck Anxiety Inventory on the same day as their routine 20-minute NST.
The Fetal Health Locus of Control Scale consists of three dimensions: Internal Health Locus of Control, Chance Health Locus of Control, and Powerful Others Health Locus of Control. NST recordings will be evaluated according to FIGO-based criteria by an experienced investigator. Baseline fetal heart rate, accelerations, reactivity, decelerations, and other relevant cardiotocographic parameters will be recorded.
This study aims prospective cross-sectional evaluation of high-risk pregnant women undergoing routine non-stress testing. The primary objective is to investigate the relationships among fetal health locus of control perceptions, maternal anxiety levels, and fetal cardiotocography parameters. Secondary analyses will examine the relationships of these variables with maternal sociodemographic and obstetric characteristics.
nebahatuzunay@gmail.com+905052609436
dcek2000@yahoo.com+905353475411
nebahatuzunay@gmail.com+905052609436