This retrospective, non-interventional clinical investigation evaluates the diagnostic performance of the Withings Hypertension Notification Feature (HTNF), a software-only medical device (SaMD) that analyzes demographic, anthropometric, and physiological parameters collected by Withings connected smart scales to identify patterns suggestive of hypertension. Ground-truth blood pressure measurements are obtained concurrently from Withings connected blood pressure monitors.
Hypertension affects approximately 1.4 billion adults worldwide and is the leading modifiable risk factor for cardiovascular disease. The Withings Hypertension Notification Feature (HTNF) is a software-only medical device (Software as a Medical Device, SaMD) that analyzes demographic, anthropometric, and physiological parameter data opportunistically collected by Withings connected smart scales to identify patterns suggestive of hypertension and provide a notification to the user. Ground-truth hypertension status is defined at the user-week level as a weekly average systolic blood pressure (SBP) >= 130 mmHg or diastolic blood pressure (DBP) >= 80 mmHg (2017 ACC/AHA guideline), based on a minimum of 7 weekly blood pressure measurements from Withings BPM devices.
Data were collected retrospectively between 2019 and 2026 from consumer users of commercially available Withings smart scales who received an information letter and did not opt out. No prospective measurements or interventions are performed.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Withings Smart Scale Users | Retrospective cohort of adult consumer users of Withings connected smart scales (Body Cardio, Body Scan, Body Comp) with concurrent Withings blood pressure monitor measurements between 2019 and 2026. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Withings Blood Pressure Monitor (reference) | Device | Ground-truth weekly average systolic and diastolic blood pressure measurements obtained from Withings connected blood pressure monitors (BPM [WPM02], BPM+ [WPM03], BPM Core [WPM04], BPM Connect [WPM05]), validated as non-invasive oscillometric blood pressure monitors per ISO 81060-2:2018. Minimum 7 measurements per user-week required. |
| Measure | Description | Time Frame |
|---|---|---|
| Stage-Adjusted Sensitivity (Se) of the Withings HTNF Algorithm | Percentage of hypertensive user-weeks correctly flagged | up to 7 years |
| Stage-Adjusted Specificity (Sp) of the Withings HTNF Algorithm | Percentage of non-hypertensive user-weeks correctly not flagged | up to 7 years |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Adult consumer users (>= 18 years, >= 22 years in the US) of Withings connected smart scales (Body Cardio, Body Scan, Body Comp) with concurrent Withings connected blood pressure monitor data, who received the study information letter and did not opt out. The retrospective validation cohort is drawn from a HealthVerity-linked US subset to support subgroup analyses by race, ethnicity, prior hypertension diagnosis, and antihypertensive medication use.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Pierre Escourrou, MD, PhD | Centre Interdisciplinaire du Sommeil, Paris, France | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Withings SA | Issy-les-Moulineaux | Île-de-France Region | 92130 | France |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006973 | Hypertension |
| ID | Term |
|---|---|
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Withings Hypertension Notification Feature (HTNF) | Device | The Withings Hypertension Notification Feature (HTNF) is a software-only medical device (Software as a Medical Device, SaMD) that analyzes demographic, anthropometric, and physiological parameter data opportunistically collected by Withings connected smart scales to identify patterns suggestive of hypertension and provide a notification to the user. |
|