Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Aorys Clinic, Sibiu, Romania | UNKNOWN |
| SC APARAT DENTAR SRL, Sibiu, Romania | UNKNOWN |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Supragingival Trimming-Line Design | Experimental | Finishing clear aligner with a straight trimming-line positioned approximately 2 mm apical to the free gingival margin, covering approximately 2 mm of gingival tissue. Assigned to the arch with greater planned intrusion; if equal or zero on both arches, assigned by pre-specified systematic alternation in enrollment order. |
|
| Juxtagingival Festooned Trimming-Line Design | Active Comparator | Finishing clear aligner with a festooned trimming-line following the natural scalloped contour of the free gingival margin, terminating at the gingival margin without covering gingival tissue. Assigned to the contralateral arch. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Tri-layer thermoplastic finishing clear aligner | Device | Finishing clear aligner fabricated from CA Pro tri-layer thermoplastic (SCHEU-DENTAL GmbH, Iserlohn, Germany; CE-marked), fabricated by SC APARAT DENTAR SRL, Sibiu, Romania. Each participant receives aligners with both trimming-line designs simultaneously - supragingival on one arch and juxtagingival festooned on the contralateral arch. Material and thickness are identical for both designs; only trimming-line geometry differs. (Cross-referenced to both arms.) |
| Measure | Description | Time Frame |
|---|---|---|
| Aligner Color Change (ΔE00) After 14 Days of Wear | Mean color change (ΔE00, CIEDE2000) of the finishing aligner between day 0 and day 14, per dental arch, computed from CIE L*, a*, b* coordinates averaged over three target positions measured in triplicate. The supragingival-design arch and the juxtagingival-design arch are compared within each participant (paired split-mouth). | Day 0 and day 14 |
| Measure | Description | Time Frame |
|---|---|---|
| Component Color Changes (ΔL*, Δa*, Δb*) | Mean changes in the individual CIE coordinates per arch between day 0 and day 14, characterizing the direction of color change (lightness; red-green; yellow-blue axes). | Day 0 and day 14 |
| Overall Aligner Color Change (ΔE00 and ΔE*ab, pooled) |
| Measure | Description | Time Frame |
|---|---|---|
| Proportion of Measurements Exceeding Perceptibility / Acceptability Thresholds | Proportion of arch-level color changes exceeding the 50:50% perceptibility (ΔE00 = 0.8) and acceptability (ΔE00 = 1.8) thresholds (Paravina 2015). Interpreted descriptively; these thresholds were established for permanent restorations compared with adjacent teeth and are used here only as a reference standard, not as a clinical failure criterion for a temporary 14-day aligner. |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| EMILIA (PRODEA) RUSU, DDS, Specialist Orthodontist | George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 38 Gheorghe Marinescu Street, 540139 Targu Mures, Romania | Principal Investigator |
| LUMINITA LAZAR, PhD, Professor | George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 38 Gheorghe Marinescu Street, 540139 Targu Mures, Romania | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Aorys Clinic | Sibiu | Sibiu County | 550118 | Romania |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 19231572 | Background | Kim-Pusateri S, Brewer JD, Davis EL, Wee AG. Reliability and accuracy of four dental shade-matching devices. J Prosthet Dent. 2009 Mar;101(3):193-9. doi: 10.1016/S0022-3913(09)60028-7. | |
| 38637429 | Background | Elshazly TM, Bourauel C, Ismail A, Ghoraba O, Aldesoki M, Salvatori D, Elattar H, Alhotan A, Alkabani Y. Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: an in vitro study. Clin Oral Investig. 2024 Apr 19;28(5):258. doi: 10.1007/s00784-024-05662-x. |
| Label | URL |
|---|---|
| Companion study PATHO-ALIGN (same investigator; partially shared participants and aligner allocation) | View source |
Not provided
De-identified individual participant data (participant codes, arch-level color change values ΔE00 and ΔE*ab, component changes ΔL*/Δa*/Δb* and baseline covariates) will be made available as a CSV or Excel file upon reasonable request to the corresponding author following publication of study results.
Beginning 6 months after publication of primary study results.
Upon reasonable request to the corresponding author (PI); requests reviewed within 30 days.
Not provided
Not provided
Within-person split-mouth design: each participant receives the supragingival design on one dental arch and the juxtagingival festooned design on the contralateral arch simultaneously, serving as their own control. Allocation is non-randomized and clinician-determined following a pre-specified hierarchical rule based on planned intrusion magnitude per arch.
Not provided
Not provided
The outcomes assessor is masked. (1) Treating clinician (orthodontist, PI): assigns the marginal termination designs to the arches at baseline, holds the participant code and allocation key, and performs the extraoral colorimetric measurements of the aligners under standardized optical conditions; not masked, as allocation is inherent to treatment planning. (2) Data manager / outcomes assessor: receives the recorded L*, a*, b* values labeled only by participant code and arch (e.g., "SPC001 maxillary", "SPC001 mandibular"), with no reference to which design was assigned to which arch, and performs all data centralization and the between-arm comparison; completely blinded to allocation. The arch-to-design key is held by the treating clinician and released only after the colorimetric dataset is locked. Probe positioning is standardized by protocol (fixed measurement height and fixed positioning references) and each target position is measured in triplicate, limiting operator influence on
|
Color change of the finishing aligner across all target positions regardless of marginal termination design, reported as ΔE00 (CIEDE2000) and, for comparability with prior literature, ΔE*ab (CIELAB), characterizing overall colorimetric stability during wear. |
| Day 0 and day 14 |
| Day 0 and day 14 |
| 36055460 | Background | Elshazly TM, Keilig L, Salvatori D, Chavanne P, Aldesoki M, Bourauel C. Effect of trimming line design and edge extension of orthodontic aligners on force transmission: An in vitro study. J Dent. 2022 Oct;125:104276. doi: 10.1016/j.jdent.2022.104276. Epub 2022 Aug 30. |
| 19634462 | Background | Gracco A, Mazzoli A, Favoni O, Conti C, Ferraris P, Tosi G, Guarneri MP. Short-term chemical and physical changes in invisalign appliances. Aust Orthod J. 2009 May;25(1):34-40. |
| 26582007 | Background | Lombardo L, Arreghini A, Maccarrone R, Bianchi A, Scalia S, Siciliani G. Optical properties of orthodontic aligners--spectrophotometry analysis of three types before and after aging. Prog Orthod. 2015;16:41. doi: 10.1186/s40510-015-0111-z. Epub 2015 Nov 18. |
| 41492584 | Background | Narkhede S, Rao P, Sawant V, Kambli S, Garg N, Shah SP, Sachdev SS. Comparative Assessment of Color Stability in Four Commercial Clear Aligner Materials Exposed to Common Beverages: An In Vitro Study. Cureus. 2025 Dec 4;17(12):e98482. doi: 10.7759/cureus.98482. eCollection 2025 Dec. |
| 39525218 | Background | G P V S, Shukla V, Ghosh M, Barde S, Mustafa M, Almokhatieb AA. Evaluation of the Root Canal Centering Ratio and Canal Transportation Associated With Three Rotary File Systems Using Cone Beam Computed Tomography (CBCT) Analysis. Cureus. 2024 Oct 8;16(10):e71117. doi: 10.7759/cureus.71117. eCollection 2024 Oct. |
| 41892738 | Background | Rusu EP, Lazar AP, Erhan BL, Bud E, Pacurar M, Lazar L. Clear Aligner Therapy and Marginal Edge Design: Clinical and Laboratory Evidence on Periodontal and Biological Outcomes-A Scoping Review. Dent J (Basel). 2026 Feb 24;14(3):130. doi: 10.3390/dj14030130. |
| ID | Term |
|---|---|
| D008310 | Malocclusion |
| ID | Term |
|---|---|
| D014076 | Tooth Diseases |
| D009057 | Stomatognathic Diseases |
Not provided
Not provided