Not provided
Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| CKX-001 | Other Identifier | ClinQure, Inc. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| NousQ Pte Ltd | UNKNOWN |
Not provided
Not provided
Not provided
This study looks at the safety and performance of the CLiKX device. The device is used to place ear tubes (also called ventilation tubes) in children and adults. These tubes help treat chronic ear fluid (otitis media with effusion) and other conditions where a doctor decides an ear tube is needed.
In this study, surgeons will use the CLiKX device to place an ear tube in the patient's ear. The study will check if the surgeon can place the tube correctly in the right position. The procedure will first be attempted with no anesthesia or with local anesthesia. If needed, the surgeon may then use mild sedation or general anesthesia.
The study will also look at how well patients tolerate the procedure by checking for side affects during the procedure.
Finally, the study will look at how the device affects the procedure and patient safety. Researchers will review how the procedure is performed and will follow patients for up to 30 days after the procedure to continue to check for any side effects..
This is a prospective, single-arm, multicenter study designed to evaluate the safety and effectiveness of the CLiKX device for the placement of tympanostomy tubes in pediatric and adult patients undergoing tympanostomy tube insertion for the treatment of chronic otitis media or other conditions requiring tympanostomy tube placement.
Eligible participants include children and adults ≥6 months of age who are scheduled to undergo tympanostomy tube insertion and have an ear canal diameter ≥4 mm.
The primary objective of the study is to evaluate procedural success (effectiveness), defined as successful incision of the tympanic membrane (myringotomy) and delivery of the tympanostomy tube into the intended position, while minimizing device-related adverse events during the procedure (safety).
Secondary objectives include the assessment of safety through 30 days post-procedure, as well as evaluation of procedural workflow and device performance.
Participants will complete study visits at the following time points: Baseline, Tympanostomy Procedure Visit, Post-Tympanostomy Procedure Visit (at discharge), and a 30-day Follow-Up Visit. Adverse events, concomitant medications, and procedural tolerability will be monitored throughout the study period.
This study is designed to support the intended use of the CLiKX device for performing myringotomy and facilitating delivery of tympanostomy tubes through the tympanic membrane in a clinical setting.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Tympanostomy Tube Treatment | Experimental | Subjects undergoing myringotomy with tympanostomy tube placement |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| CLiKX® Tympanostomy Tube Delivery System | Device | The CLiKX device is an automated, sensor-optimized, partially reusable handheld surgical device used for tympanostomy tube placement. It consists of multiple components assembled before use and disassembled after the procedure. The device includes integrated, pre-programmed software that controls its mechanical actions. The software is locked, cannot be modified by users, and does not perform diagnostic or therapeutic decision-making. Instead, it provides visual cues and applies controlled force to assist the procedure. Compared to manual techniques, the CLiKX device automates key steps, including creating a precise slit incision using regulated force. This approach is designed to reduce operator variability, minimize trauma to the tympanic membrane, and improve accuracy of tube placement. Clinicians retain full control over targeting throughout the procedure. |
| Measure | Description | Time Frame |
|---|---|---|
| Effectiveness of C-TTDS for tympanostomy tube placement | Effectiveness will be determined by success at the end of each ear tube procedure. Effectiveness is defined as the successful incision in the tympanic membrane and delivery of tympanostomy tube across the tympanic membrane in the proper position after a maximum of 2 insertion attempts per indicated ear. An insertion attempt is defined as an incision in the tympanic membrane by the C-TTDS | At time of procedure (first or second attempt) |
| Safety of C-TTDS for tympanostomy tube placement | Safety will be assessed by incidence, severity and relatedness of device related adverse events occurring during the overall procedure. | At time of procedure (first or second attempt) |
| Measure | Description | Time Frame |
|---|---|---|
| FLACC Pain Scale | Face, Legs, Activity, Cry, and Consolability observational pain rating scalle for Infants and children less greater than or equal to 6 months to 5 years of age. | ≤ 1.0 hour after completion of the tympanostomy procedure at the Post-Tympanostomy Procedure Visit |
| FPS-R |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Crystal George | Contact | 972-999-2070 | crystal@clinqure.com |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D010033 | Otitis Media |
| D010034 | Otitis Media with Effusion |
| ID | Term |
|---|---|
| D010031 | Otitis |
| D004427 | Ear Diseases |
| D010038 | Otorhinolaryngologic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
Faces Pain Rating Scale - Revised self-reporting pain rating scale for children greater than or equal to 5 to 7 years of age |
| ≤ 1.0 hour after completion of the tympanostomy procedure at the Post-Tympanostomy Procedure Visit |
| NRS Pain Scale | 11-point Number Rating Scale for Pain. Provided to children, adolescents, and adults greater than or equal to 7 years of age | ≤ 1.0 hour after completion of the tympanostomy procedure at the Post-Tympanostomy Procedure Visit |
| Caregiver Satisfaction Survey | Procedure satisfaction and acceptability will be assessed using a subject-, parent-, guardian-, and/or caregiver-reported satisfaction survey evaluating procedure tolerability, satisfaction, perceived importance of alternatives to general anesthesia, perceived reduction in cost and procedure time, and willingness to recommend the procedure to others. Survey responses will be assessed using a 5-point Likert scale:
Higher scores indicate greater procedure satisfaction and acceptability. | ≤ 1.0 hour after completion of the tympanostomy procedure |
| Physician Procedure Tolerability Evaluation | Performing surgeon and anesthesiologist acceptability of subject tolerability of the procedure. Binary 'Yes' or 'No' response | ≤ 1.0 hour after completion of the tympanostomy procedure |