Local data has shown conflicting results regarding the outcomes of volar locking plates versus external fixators in distal intra-articular radius fractures. Therefore, the current study was planned with the objective of comparing the outcome of a volar locking plate versus an external fixator in distal intra-articular radius fractures.
Determining which method provides superior early functional recovery through this study would be beneficial for generating local data. Understanding and applying improved anatomical reduction techniques and achieving lower complication rates would enable these individuals to mobilize and return to their daily lives more quickly, ultimately enhancing their quality of life.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group-A | Experimental | Patients will be treated with volar locking plates. The distal radius fragments will be stabilized using the conventional modified Henry's volar technique with 2.4 mm locking compression plates. |
|
| Group-B | Experimental | Patients will be employed with an external fixator, directly fixing to the second or third metacarpal bone using 3-mm pins and the radius using 4-mm Schanz pins. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Volar locking plates | Procedure | Patients will be treated with volar locking plates. The distal radius fragments will be stabilized using the conventional modified Henry's volar technique with 2.4 mm locking compression plates. |
| Measure | Description | Time Frame |
|---|---|---|
| Operative time | Operative time will be measured in minutes from skin incision to skin closure. | 2 hours |
| Blood Loss | Blood loss will be estimated in milliliters, measuring clots in a suction bottle, the difference between the pre- and postoperative sponge weights using the 1 g-1 ml formula, and blood clots in a clenched fist. | 3 hours |
| Wrist function | Wrist function will be evaluated using the Mayo Wrist Score. Patient frequencies will be recorded, with scores of 90-100 points reflecting an excellent outcome, 80-89 points indicating a good outcome, 60-79 points representing a satisfactory outcome, and scores below 60 points denoting a poor outcome. | 3 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Burhan Ulhaq | Contact | +923326456246 | burhankhan224@gmail.com | |
| Abdul-Munaf Saud, FCPS | Contact | +923005111668 | drabdulmunafsaud@gmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Burhan Ulhaq | Bahawal Victoria Hospital/Quid-e-Azam Medical College, Bahawalpur | Principal Investigator |
| Abdul-Munaf Saud, FCPS | Bahawal Victoria Hospital/Quaid-e-Azam Medical College, Bahawalpur | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Bahawal Victoria Hospital | Recruiting | Bahawalpur | Punjab Province | 63100 | Pakistan |
Data can be shared on a reasonable request.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D057072 | Intra-Articular Fractures |
| ID | Term |
|---|---|
| D050723 | Fractures, Bone |
| D014947 | Wounds and Injuries |
Not provided
Not provided
| ID | Term |
|---|---|
| D016267 | External Fixators |
| ID | Term |
|---|---|
| D009984 | Orthopedic Fixation Devices |
| D009983 | Orthopedic Equipment |
| D013523 | Surgical Equipment |
| D004864 | Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| External Fixator | Procedure | Patients will be employed with an external fixator, directly fixing to the second or third metacarpal bone using 3-mm pins and the radius using 4-mm Schanz pins. |
|
| D053831 | Surgical Fixation Devices |