Research Background:Subcutaneous injection is an important route of administration in targeted therapy for breast cancer, but injection pain affects patients' treatment experience. Fluctuations in injection speed during traditional manual push may be one of the factors exacerbating pain, whereas machine-driven injection can provide a constant flow rate, theoretically reducing pain; however, high-quality evidence is lacking.
Research Objective:To compare the difference in pain intensity between instrument constant-speed injection and manual injection in breast cancer patients receiving subcutaneous injection of pertuzumab and trastuzumab.
Research Methods:A randomized self-controlled design is used, with data analysis performed using paired t-tests. The study plans to enroll 40 female breast cancer patients. Each patient receives two injection methods across two treatment cycles: instrument constant-speed injection (medical infusion pump, 2 mL/min) and manual injection (a nurse uses a stopwatch to time and simulates the injection pump speed of 2 mL/min). The order of injection methods is randomly assigned by drawing lots (the injection method for the first cycle is randomly drawn, and the method for the second cycle is naturally the alternative method). The primary outcome is the patient's most severe pain during injection, measured immediately after injection using the Numerical Rating Scale (NRS, 0-10). Secondary outcomes include injection site reactions, patient satisfaction, nurse fatigue (Borg CR10 scale), patient preference, and safety indicators.
Research Significance:The results of this study will provide high-level evidence for selecting comfortable and efficient subcutaneous injection techniques in clinical practice, thereby improving patients' treatment experience.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Instrument-driven constant-rate injection | Experimental | Drug preparation followed the standard procedure. A fixed team of two nurses, trained according to the study protocol, performed the instrument-driven injection. The nurses, after training, used the syringe pump BeneFusion SP3 (card number: 081787) and set the infusion rate at 2 mL/min according to the drug instructions. Standard procedures were followed for injection site, disinfection, etc. The syringe model and needle gauge were consistent with those used in the manual injection group (control group). During the injection, the number of patient-reported pain episodes and immediate pain scores were recorded. The instrument preparation time was recorded, including the time from "taking the instrument - connecting the power - installing the syringe - setting parameters", as well as the time from "turning off the power - tidying up the instrument" after injection completion. The patient's blood pressure and pulse were recorded before, during, and after the injection. |
|
| Manual injection | Active Comparator | Drug preparation followed the standard procedure. A fixed team of two nurses, trained according to the study protocol, performed manual injection. The nurses, after training, simulated the speed of the machine injection and recorded the actual injection time using a stopwatch. During the injection, the number of patient-reported pain episodes, immediate pain scores, and the number of times the nurse interrupted the injection due to hand fatigue were recorded. The patient's blood pressure and pulse were recorded before, during, and after the injection. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Instrument-driven constant-rate injection | Other | Drug preparation followed the standard procedure. A fixed team of two nurses, trained according to the study protocol, performed manual injection. The nurses, after training, simulated the speed of the machine injection and recorded the actual injection time using a stopwatch. During the injection, the number of patient-reported pain episodes, immediate pain scores, and the number of times the nurse interrupted the injection due to hand fatigue were recorded. The patient's blood pressure and pulse were recorded before, during, and after the injection. |
| Measure | Description | Time Frame |
|---|---|---|
| Pain intensity score | Measure using the Numerical Rating Scale (NRS, 0-10) | Assess immediately after injection, and at 30 minutes, 24 hours, and 48 hours after injection |
| Pain intensity score | Assess immediately after injection, and at 30 minutes, 24 hours, and 48 hours after injection,Measure using the Numerical Rating Scale (NRS, 0-10) | Assess immediately after injection, and at 30 minutes, 24 hours, and 48 hours after injection |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Yanting Peng, Bachelor's Degree | Contact | 86+13710350704 | 472195985@qq.com | |
| Yunfang Yu, Doctoral Degree / Ph.D. | Contact | 86+18928926137 | 18324208@QQ.com |
| Name | Affiliation | Role |
|---|---|---|
| Yanting Peng, Bachelor's Degree | Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University | Principal Investigator |
| Sun Yat-sen University | Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical Ethics Committee of Sun Yat-sen Memorial Hospital, Sun Yat-sen University | Guangzhou | Guangdong | 510000 | China |
Not provided
| Label | URL |
|---|---|
| Related Info | View source |
Not provided
This is a small - scale exploratory study focused on internal hypothesis - testing and preliminary mechanism analysis. The data is not intended for external collaboration, as it lacks sufficient generalizability to support broader scientific inferences. All findings are based on aggregated and de - identified results reported in the main publication.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| ID | Term |
|---|---|
| D001943 | Breast Neoplasms |
| D010146 | Pain |
| ID | Term |
|---|---|
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D001941 | Breast Diseases |
| D012871 | Skin Diseases |
| D017437 | Skin and Connective Tissue Diseases |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided