Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Is patient specific customized computer assisted 3D PEEK plates more superior to 3D titanium plate in fixation of mandibular angle fractures?
Open Reduction Internal fixation (ORIF) of mandibular angle fractures using titanium plating systems had several drawbacks including sepsis with subsequent wound dehiscence and the need for 2nd surgery which is attributed to bone loss as a result of the elevated modulus of elasticity of titanium hardware. Accordingly, attempts were made to overcome problems encountered with the titanium plating system. In this study, custom made PEEK 3D plates will be used in ORIF of mandibular angle fractures. The main beneficial property of PEEK material is its lower modulus of elasticity that is close to that of living bone with subsequent elimination of the problem of stress shielding phenomenon encountered with titanium plating system. PEEK material has other advantages including biocompatibility, mechanical strength, durability, resistance to high degree of temperature without dimensional alteration.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Computer-assisted PEEK custom made 3D plates | Experimental | Patients were treated using computer-assisted patient-specific PEEK plates manufactured by CAD/CAM technology and fixed using titanium screws. |
|
| 3D titanium plates on the mandibular angle will be fixed using titanium screws | Active Comparator | Patients were treated using conventional 3D titanium plates fixed with titanium screws after reduction of the fracture. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Patient-specific PEEK plates manufactured using CAD/CAM technology and fixed using titanium screws. | Device | Patient-specific PEEK plates manufactured using CAD/CAM technology and fixed using titanium screws. |
| Measure | Description | Time Frame |
|---|---|---|
| Postoperative occlusion stability(binary: yes/no) | Occlusal stability was recorded as stable or unstable. Occlusal stability was assessed clinically by evaluating the intercuspation between maxillary and mandibular teeth. Proper occlusion was defined as normal intercuspation without premature contacts or occlusal discrepancies. Any deviation, including open bite or malocclusion, was recorded during follow-up. | 1 week, 1 month, and 6 months postoperatively |
| Measure | Description | Time Frame |
|---|---|---|
| Condylar seating (binary: yes/no) | Condylar seating was assessed radiographically using standardized panoramic radiographs. The position of the mandibular condyle within the glenoid fossa was evaluated. Proper condylar seating was defined as a normal anatomical position without displacement. Any deviation from the normal position was recorded as improper. | 1 week, 1 month, and 6 months postoperatively |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Hamida Refaae, PhD | Cairo University | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Osama Abdelaziz Abdelreheem | Cairo | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 35725512 | Background | Maurice V, Russet F, Scocco P, McNicholas F, Santosh P, Singh SP, Street C, Purper-Ouakil D. Transition from child and adolescent mental health care to adult services for young people with Attention-Deficit/Hyperactivity Disorder (ADHD) or Autism Spectrum Disorder (ASD) in Europe: Barriers and recommendations. Encephale. 2022 Oct;48(5):555-559. doi: 10.1016/j.encep.2022.01.012. Epub 2022 Jun 18. | |
| 34072671 |
| Label | URL |
|---|---|
| Background information on mandibular angle fracture fixation using 3D PEEK and titanium plates. | View source |
Not provided
Individual participant data (IPD) will not be shared due to privacy and confidentiality considerations.
Not provided
Not provided
Not provided
Not provided
Not provided
Two groups of patients were assigned in this randomized clinical trial.
Group I (Study group): Patients were treated using patient-specific customized 3D PEEK plates for fixation of mandibular angle fractures.
Group II (Control group): Patients were treated using conventional 3D titanium plates for fixation of mandibular angle fractures.
Not provided
Not provided
This study is an open-label randomized clinical trial. Due to the nature of the surgical intervention, blinding of participants and surgeons was not feasible.
Not provided
| Conventional 3D titanium plates | Device | Conventional 3D titanium plates used for fixation of mandibular angle fractures with titanium screws. |
|
| Postoperative infection (binary: yes/no) | Postoperative infection was recorded as present or absent. | 1 week, 1 month, and 6 months postoperatively |
| Wound dehiscence (binary: yes/no) | Wound dehiscence was recorded as present or absent. | 1 week, 1 month, and 6 months postoperatively |
| Need for second surgical intervention ( binary: yes/no) | Need for second surgery was recorded as yes or no. | 1 week, 1 month, and 6 months postoperatively |
| Background |
| Fun WH, Tan EH, Sararaks S, Md Sharif S, Ab Rahim I, Jawahir S, Eow VHY, Sibert RMY, Fadzil MM, Mahmud SH. Implications of Dual Practice on Cataract Surgery Waiting Time and Rescheduling: The Case of Malaysia. Healthcare (Basel). 2021 May 31;9(6):653. doi: 10.3390/healthcare9060653. |
| 35418201 | Background | Amir O, Goldberg Y, Mandel M, Bar-On YM, Bodenheimer O, Ash N, Alroy-Preis S, Huppert A, Milo R. Protection following BNT162b2 booster in adolescents substantially exceeds that of a fresh 2-dose vaccine. Nat Commun. 2022 Apr 13;13(1):1971. doi: 10.1038/s41467-022-29578-w. |
| ID | Term |
|---|---|
| D008337 | Mandibular Fractures |
| ID | Term |
|---|---|
| D007572 | Jaw Fractures |
| D008446 | Maxillofacial Injuries |
| D005151 | Facial Injuries |
| D006259 | Craniocerebral Trauma |
| D020196 | Trauma, Nervous System |
| D009422 | Nervous System Diseases |
| D012887 | Skull Fractures |
| D050723 | Fractures, Bone |
| D014947 | Wounds and Injuries |
Not provided
Not provided