This prospective randomized controlled study evaluated the effects of different endotracheal tube cuff pressure monitoring strategies on postoperative airway complications in patients undergoing elective laparoscopic abdominal surgery under general anesthesia. Excessive endotracheal tube cuff pressure may impair tracheal mucosal perfusion and lead to postoperative airway symptoms such as sore throat, cough, dysphagia, hoarseness, and hemoptysis.
A total of 95 adult patients (ASA I-II) aged 18-65 years were randomly assigned to one of three groups according to the cuff pressure monitoring technique used during surgery: the cuff-leak technique (control group), intermittent cuff pressure monitoring using a manual manometer every 30 minutes, or continuous cuff pressure monitoring using a pressure transducer connected to the pilot balloon.
The primary outcome was the incidence of cuff-related postoperative airway complications at postoperative hours 2 and 24. Secondary outcomes included tracheal mucosal injury assessed by fiberoptic bronchoscopy before extubation and its association with postoperative airway symptoms. The study aimed to determine whether continuous cuff pressure monitoring reduces postoperative airway complications and tracheal mucosal injury compared with intermittent monitoring and the cuff-leak technique.
Endotracheal tube cuff pressure should be maintained between 20 and 30 cmH₂O to ensure adequate ventilation while preventing tracheal mucosal ischemia. Excessive cuff pressure may compromise tracheal mucosal perfusion and lead to postoperative airway complications such as sore throat, cough, hoarseness, dysphagia, and hemoptysis. In laparoscopic surgery, factors such as pneumoperitoneum, patient positioning, and the use of nitrous oxide may contribute to progressive increases in cuff pressure during anesthesia.
This prospective randomized controlled trial was conducted to evaluate the impact of different cuff pressure monitoring strategies on postoperative airway complications and tracheal mucosal injury in adult patients undergoing elective laparoscopic abdominal surgery. After obtaining ethical approval and written informed consent, patients were randomized into three groups according to the cuff pressure monitoring method used intraoperatively: cuff inflation using the cuff-leak technique (control group), intermittent cuff pressure monitoring with a manual manometer every 30 minutes, or continuous cuff pressure monitoring using a pressure transducer connected to the pilot balloon.
Cuff pressure in the monitored groups was maintained at approximately 25 cmH₂O throughout surgery. Postoperative laryngopharyngeal symptoms, including sore throat, cough, dysphagia, hoarseness, and hemoptysis, were assessed at postoperative hours 2 and 24 by a blinded observer. Tracheal mucosal changes were evaluated using fiberoptic bronchoscopy before extubation and graded according to established criteria.
The aim of the study was to determine whether continuous cuff pressure monitoring provides better control of cuff pressure and reduces postoperative airway complications and tracheal mucosal injury compared with intermittent monitoring and the cuff-leak technique.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Intermittent Cuff Pressure Monitoring | Experimental | Endotracheal tube cuff pressure was adjusted to 25 cmH₂O using a manual manometer and rechecked every 30 minutes during surgery. If cuff pressure was outside the range of 20-30 cmH₂O, it was readjusted accordingly. |
|
| Continuous Cuff Pressure Monitoring | Experimental | Endotracheal tube cuff pressure was continuously monitored using a pressure transducer connected to the pilot balloon via a three-way stopcock. Cuff pressure was maintained at approximately 25 cmH₂O throughout surgery. |
|
| Cuff-Leak Technique (Control) | Active Comparator | The endotracheal tube cuff was inflated using the cuff-leak technique without objective cuff pressure measurement. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Intermittent cuff pressure monitoring | Procedure | Endotracheal tube cuff pressure was adjusted to 25 cmH₂O using a manual manometer and rechecked every 30 minutes during surgery. If the pressure was outside the range of 20-30 cmH₂O, it was readjusted accordingly. |
| Measure | Description | Time Frame |
|---|---|---|
| Incidence of postoperative airway complications | The incidence of postoperative airway complications including sore throat, cough, dysphagia, hoarseness, and hemoptysis assessed at postoperative hours 2 and 24. | Postoperative 2 hours and 24 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Tracheal mucosal injury assessed by fiberoptic bronchoscopy | Tracheal mucosal injury evaluated using fiberoptic bronchoscopy before extubation and graded according to mucosal findings (no injury, focal hyperemia, local hyperemia, hemorrhagic ulceration). | Before extubation (end of surgery) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Fevzi Güler, MD, Anesthesiologist | Cukurova University Faculty of Medicine | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Cukurova University Faculty of Medicine, Department of Anesthesiology and Reanimation | Adana | Adana | 01330 | Turkey (Türkiye) |
No plan to share individual participant data because the dataset contains confidential patient information and was collected for a single-center academic study.
Not provided
Not provided
Not provided
Not provided
Not provided
Participants were randomly assigned to one of three parallel groups according to the endotracheal tube cuff pressure monitoring strategy used during surgery: intermittent cuff pressure monitoring with a manual manometer every 30 minutes, continuous cuff pressure monitoring using a pressure transducer connected to the pilot balloon, or the cuff-leak technique without pressure measurement (control group).
Not provided
Not provided
Outcome assessments were performed by an independent investigator who was blinded to group allocation.
| Continuous cuff pressure monitoring | Procedure | Endotracheal tube cuff pressure was continuously monitored using a pressure transducer connected to the pilot balloon via a three-way stopcock and maintained at approximately 25 cmH₂O throughout surgery. |
|
| Cuff-leak technique | Procedure | The endotracheal tube cuff was inflated using the cuff-leak technique without objective cuff pressure measurement. |
|