A Comparison of Three Difficult Intubation Techniques in Patients With Anticipated Difficult Intubation: A Prospective, Randomized, Parallel-group Clinical Trial
A Comparison of Three Difficult Intubation Techniques in Patients With Anticipated Difficult Intubation: A Prospective, Randomized, Parallel-group Clinical Trial
The aim of this study was to compare three different awake tracheal intubation technique
-fiberoptic bronchoscopy (ATI:FB), videolaryngoscopy (ATI:VL), and fiberoptic bronchoscopy via a supraglottic airway device (ATI:SAD)- in terms of success rates, intubation times, and complications. Additionally, the study aims to evaluate the reliability of the SAD-assisted ATI method and its potential to contribute to the literature.
Awake tracheal intubation (ATI) is a technique considered the gold standard for managing anticipated difficult airways. The success of ATI is based on two key physiological advantages: the preservation of spontaneous breathing and the maintenance of airway tone. Traditionally, ATI is performed using a flexible fiberoptic bronchoscope (ATI:FB). However, in recent years, ATI techniques performed using video laryngoscopy (ATI:VL) have also become widespread and have particularly stood out for their shorter intubation times.
Although randomized studies directly comparing ATI:FB and ATI:VL techniques are limited in the literature, an increasing number of studies are evaluating the comparative efficacy of these techniques. On the other hand, while supraglottic airway devices (SADs) are traditionally used as rescue ventilation devices, current guidelines indicate that they can also serve as a channel for awake intubation in conjunction with fiberoptic bronchoscopy . Various case series and small-scale observational studies exist on this topic. However, there are no prospective studies directly comparing SAD use during ATI with traditional methods such as ATI:FB and ATI:VL. This gap in the literature forms the primary rationale for our study.
The ATI:SAD method currently used in our clinic is a technique in which the Aintree catheter and fiberoptic bronchoscope are utilized via SAD. This method offers advantages such as the ability to continuously monitor spontaneous breathing and maintain uninterrupted oxygenation. In this context, our study aims not only to demonstrate the efficacy of the ATI:SAD method but also to contribute this method to the literature.
Inclusion Criteria:
Exclusion Criteria:
drmyilmaz33@gmail.com+905052174432
ayse.zeynep@gmail.com05054695850