Functional Outcomes and Control Using Synchron BCI - Canada (FOCUS-CAN)
Functional Outcomes and Control Using Synchron BCI - Canada (FOCUS-CAN):
The Synchron BCI motor neuroprosthesis is an implanted brain-computer interface indicated for adults with bilateral upper-limb motor impairment, including Motor Neuron Disease. The Synchron BCI is intended to replace the function of motor neurons by detecting, translating and transmitting motor-related brain signals to restore clinically meaningful control of digital devices.
The Synchron BCI is an implanted BCI device that interfaces with the brain to enable control of digital devices in individuals with bilateral upper-limb motor impairment. The Synchron BCI is designed to record volitional motor-related neural signals from the sensorimotor cortices and translate these signals into digital motor outputs to enable control of digital devices to improve functional independence. The system includes both implantable and non-implantable components. Implantable components are the Stentrode and the Transceiver.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Single | Other | Single Arm |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Stentrode | Device | The Stentrode is an endovascular electrode array that senses electrical signals from the sensorimotor cortices. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Device-related serious adverse events resulting in death or permanently increased disability up to 90 days after implant. | 3 Months |
| Measure | Description | Time Frame |
|---|---|---|
| Device-related serious adverse events resulting in death or permanently increased disability up to 1 year after implant. | 12 Months | |
| Target vessel patency assessed using CT venography at 90 and 365 days after implant. | 3 Months and 12 Months |
| Measure | Description | Time Frame |
|---|---|---|
| Time in days from implant to device activation. | Number of days from device implant to device activation, up to 12 months after implant. | |
| Stability of recorded BCI signal, using monthly measurements up to 1 year after device implant. | 12 Months |
INCLUSION CRITERIA:
EXCLUSION CRITERIA:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Jami Smith | Contact | 323-796-2476 | jsmith@synchron.com | |
| Omid Forouzan | Contact | 323-796-2476 |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Sunnybrook Health Sciences Centre | Recruiting | Toronto | Ontario | M5C 1N2 | Canada |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D009422 | Nervous System Diseases |
| D016472 | Motor Neuron Disease |
| ID | Term |
|---|---|
| D019636 | Neurodegenerative Diseases |
| D009468 | Neuromuscular Diseases |
Not provided
Not provided
Insertion of Stentrode Device
Not provided
Not provided
Not provided
Not provided
| Device migration assessed using CT venography at 90 and 365 days after implant. | 3 Months and 12 Months |