Pseudophakic Eyes Implanted With Different Presbyopia-correcting IOL Designs: 3-D Anterior Segment OCT Biometry and Pyramid Wavefront Sensing- Based Retinal Image Quality
Pseudophakic Eyes Implanted With Different Presbyopia-correcting IOL Designs: 3-D Anterior Segment OCT Biometry and Pyramid Wavefront Sensing- Based Retinal Image Quality
To correlate ocular morphology from anterior segment OCT and pyramid wavefront sensing in order to comprehensively analyze pseudophakic in vivo image quality of presbyopia-correcting IOLs in cataract patients.
Improvements in cataract surgery and the introduction of different intraocular lenses (IOLs) have transformed the operation from a simple therapeutic procedure to a refractive surgical procedure. A large number of currently available IOL designs are not limited to correcting refractive errors and astigmatism, but can also compensate for corneal sphericity and/or moderate presbyopia by inducing multifocality or extending the depth of focus.
The three-dimensional representation of the anterior segment of the eye has been facilitated in eye surgery by the introduction of optical coherence tomography (OCT), and imaging techniques such as spectral domain OCT (SD-OCT) and swept-source OCT (SS OCT) are particularly well suited for the quantitative characterization of eye dimensions. This offers the possibility of creating biometric eye models and using the non-paraxial regime for characterizing eye optics.
Similarly, the introduction of ocular wavefront aberrometry at the turn of the millennium led to a paradigm shift in the evaluation of clinical optical imaging quality and the derivation of objective optical metrics. Furthermore, internal lens aberrations can be quantified by direct subtraction from anterior segment tomography. However, high-resolution eye tomography and wavefront aberrometry are rarely comprehensively linked.
A pyramidal wavefront sensor (PWS) Osiris-T (CSO, Italy) was recently introduced, which can measure the ocular wavefront with a significantly higher lateral resolution. In addition, tomographic parameters of the anterior segment can be imported directly into the device to examine the clinical optical performance of IOL implants. This provides the ability to combine 3-D OCT biometry of the anterior segment and high-resolution wavefront aberrometry.
A total of 160 eyes of 80 patients will be included.
Inclusion Criteria:
Exclusion Criteria:
6) Zonular weakness 7) Pseudoexfoliation syndrome 8) Eccentric fixation or insufficient ability to fixate (tremor, nystagmus) 9) Pregnancy