This study will evaluate the patient specific surgical stent and plate for guided reduction and fixation of mandibular angle fractures.
seven patients with recent mandibular angle fractures indicated for open reduction and internal fixation were treated by patient specific surgical stent and plate for guided reduction and fixation of mandibular angle fractures. Follow-up extended to 12 weeks. Clinical parameters included pain, operative time, postoperative occlusion, wound healing and mouth opening. Radiographic evaluation was conducted using computed tomography scans acquired preoperatively and postoperatively ,superimposition of the pre and postoperative models will be done to create error map and measure the accuracy
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| patients with recent mandibular angle fractures managed with patient specific stents and plates | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Patient specific surgical stents and plates for guided reduction and fixation of mandibular angle fixation | Device | Patient specific surgical stents and plates for guided reduction and fixation of mandibular angle fixation |
| Measure | Description | Time Frame |
|---|---|---|
| Evaluation of accuracy of surgical reduction and fixation | Evaluation of accuracy of surgical guide will be done using slicer and blender, and mimics software with the aid of the preoperative and postoperative CT. Preoperative planning will be merged with the new CT data to identify the accuracy of reduction. | Day 1 |
| Measure | Description | Time Frame |
|---|---|---|
| Clinical evaluation for Intra-opreative time | Intra-opreative |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Faculty of dentistry, Alexandria university | Alexandria | 21523 | Egypt |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001860 | Bone Plates |
| ID | Term |
|---|---|
| D016268 | Internal Fixators |
| D019736 | Prostheses and Implants |
| D004864 | Equipment and Supplies |
| D009984 | Orthopedic Fixation Devices |
| D009983 | Orthopedic Equipment |
| D013523 | Surgical Equipment |
| D053831 | Surgical Fixation Devices |
Not provided
Not provided