Pilot interventional randomized clinical trial to study the efficacy of left bundle branch pacing in patients with hypertrophic cardiomyopathy after myectomy for the prevention of progression of heart failure, prevent the occurrence of life-threatening rhythm disturbances and promote reverse remodeling of the LV.
The aim of the study is to evaluate the comparative efficacy and safety of implantation of a cardioverter-defibrillator with left bundle branch block pacing and a dual-chamber cardioverter-defibrillator in patients with HCM and complete left bundle branch block after myectomy at high risk of SCD.
Objectives of the study:
After a discussion about the possibility of participating in the study, the patient is presented with an informed consent form and all questions of interest are explained. If consent to participate in the study is obtained, the patient and the researcher fill in all the required fields of two copies of the informed consent form and sign it. If necessary, the researcher re-explains any information regarding the study. Once informed consent has been obtained, an Individual Registration Card (IRC) is completed for the patient enrolled in the study. Completion of the IRC also continues until the completion of all stages of the study.
30 patients (15 patients in each group) will be randomly separated into 2 groups: dual-chamber ICD and a dual-chamber ICD with LBB pacing.
Initial data:
Intraoperative:
Hospitalization period:
ICD Implantation with Left Bundle Branch Pacing: Incision in the left or right connector area parallel to the key. Vein puncture. Electrodes are passed through the introducer system. Before implantation, a safety electrode is implanted in the LBBB at the apex of the right ventricle.
The His bundle is recorded 1-1.5 cm apically (toward the apex of the right ventricle) in the area of the interventricular septum. Pacing from this area of the QRS complex in lead V1 has a "W" morphology. Insert the electrode into the thick interventricular septum. After each ventricular extrasystole, stop inserting and measure the following parameters:
Statistical analysis:
Comparisons of continuous outcomes will be performed using the Mann-Whitney test for non-normal variables and the Welch t-test for normal variables. Comparisons of binary outcomes will be performed using the chi-square test or Fisher's exact test.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group 1: Left bundle branch area pacing (LBBAP) | Experimental | Participants assigned to Group 1 will implantation of a dual-chamber cardioverter-defibrillator with left bundle branch block pacing |
|
| Group 2: Dual-chamber cardioverter-defibrillator | Active Comparator | Participants assigned to Group 2 will implantation of a dual-chamber cardioverter-defibrillator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| ICD with left bundle branch area pacing (LBBAP) | Device | Incision in the left or right connector area parallel to the key. Vein puncture. Electrodes are passed through the introducer system. Before implantation, a safety electrode is implanted in the LBBB at the apex of the right ventricle. The His bundle is recorded 1-1.5 cm apically (toward the apex of the right ventricle) in the area of the interventricular septum. Pacing from this area of the QRS complex in lead V1 has a "W" morphology. Insert the electrode into the thick interventricular septum. After each ventricular extrasystole, stop inserting and measure the following parameters:
|
| Measure | Description | Time Frame |
|---|---|---|
| Serious Adverse Events | Absence of procedural complications requiring emergency surgical intervention (major bleeding, pneumothorax, tamponade, etc.) | 48 hours |
| Efficiency | Technical Success of the Procedure
Time Frame: At the time of implantation. | 3-6-12 month |
| Measure | Description | Time Frame |
|---|---|---|
| Hospitalization for heart failure, assessment of the functional class of CH, measurement of NT-proBNP, assessment of LV remodeling, antitachycardia and shock therapy, paroxysms of supraventricular tachycardia, quality of life |
|
Not provided
Inclusion criteria:
Exclusion criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Valentina Sergeevna Kirilova, PhD, MD | Contact | +79044714203 | kirilova_v@meshalkin.ru |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Meshalkin Scientific Research Center of the Ministry of Health of Russia | Recruiting | Novosibirsk | Novosibirsk Oblast | 630055 | Russia |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| dual-chamber ICD | Device | Under local anesthesia, an incision was made parallel to the clavicle in the left junctional area. A subcutaneous bed for the pacemaker was created. Hemostasis was maintained. The communicating vein was punctured from the wound, and through a system of introducers, it was continuously fixed in the right ventricular septum under fluoroscopic control. The electrode was fixed with a U-shaped suture. The communicating vein was again punctured, and through the system of introducers, an electrode was inserted, which was firmly fixed in the right atrial appendage under fluoroscopic control. The electrode was fixed with a U-shaped suture. The electrodes are connected to the pacemaker. Layered wound suturing is performed. An aseptic dressing is applied. |
|
| 3-6-12 month |
| ID | Term |
|---|---|
| D002312 | Cardiomyopathy, Hypertrophic |
| D016757 | Death, Sudden, Cardiac |
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D009202 | Cardiomyopathies |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D001020 | Aortic Stenosis, Subvalvular |
| D001024 | Aortic Valve Stenosis |
| D000082862 | Aortic Valve Disease |
| D006349 | Heart Valve Diseases |
| D006323 | Heart Arrest |
| D003645 | Death, Sudden |
| D003643 | Death |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D017147 | Defibrillators, Implantable |
| ID | Term |
|---|---|
| D047548 | Defibrillators |
| D004566 | Electrodes |
| D055615 | Electrical Equipment and Supplies |
| D004864 | Equipment and Supplies |
| D004567 | Electrodes, Implanted |
| D019736 | Prostheses and Implants |
Not provided