| Name | Class |
|---|---|
| Medtronic | INDUSTRY |
Not provided
Not provided
Not provided
A third generation, Micra AV2 is now available and proposes increased automaticity and improved AV synchrony algorithms based on computing model. The new algorithms permit the delivery of AV synchronous pacing, improving the automatic AV synchrony at faster heart rates between 80-100 bpm with a maximal upper tracking rate limit of 135 bpm (previously 115-120 bpm in the Micra AV1). Micra AV2 presents also a potential extended longevity of 15.6 years (increased by > 44% in comparison of Micra AV1). Up to now, no clinical study has evaluated the efficacy and safety of Micra AV2 in a real-world setting.
The focus of this study is to characterize chronic ambulatory AV synchrony in patients with high degree AV block and normal sinus rhythm implanted with a Micra AV2 as primary objective to evaluate AV synchrony during exercise as secondary objective.
Prospective, single-arm, multi-centre clinical study to characterize the chronic efficacy and safety profile of CE approved and market released Micra AV2 A sample size of approximately 150 subjects implanted with a Micra AV2 is required to evaluate the different objectives. A minimal sample size of 50 subjects with persistent 3rd degree AVB and normal sinus node function is required to evaluate the ambulatory AV synchrony at 6-month follow-up.
Primary objective:
Characterize ambulatory AV synchrony in subjects with persistent third degree AV block and normal sinus node function at 6-month post Micra AV2 implant procedure
Secondary objective(s):
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Micra AV | Experimental | All patients will receive a Micra AV2 leadless pacemaker |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Implant procedure of a Micra AV2 leadless pacemaker (Medtronic) | Device | All patients will be implanted with aMicra AV2 leadless pacemaker |
|
| Measure | Description | Time Frame |
|---|---|---|
| AV synchrony at 6 months | AV synchrony will be computed on an individual heartbeat basis and is defined as met for paced or sensed ventricular beats that are within 300 ms following an ECG confirmed P-wave. This endpoint will be used for the primary objective , for the secondary objective #1 (AV synchrony during exercise at 6-month post-implant) and for the secondary objective #3 (evaluation of the AV synchrony following the automated atrial sensing setup) | 6 months follow-up |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
-1. Subject implanted with a Micra AV2 on a non-permanent basis (e.g. CIED infection) 2. Subject is pregnant (if required by local law, women of child-bearing potential must undergo a pregnancy test within seven days prior to Micra AV2 implant procedure) 3. Subject currently enrolled or planning to participate in a potentially confounding drug or device trial during the study.
4. Subject meets any exclusion criteria required by local law (age or other)
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Christophe Y Garweg, Professor | Contact | +32163444248 | christophe.garweg@uzleuven.be | |
| Caroline Devooght, Miss | Contact | +3216344248 | caroline.devooght@uzleuven.be |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Hospitals of Leuven | Recruiting | Leuven | Flemish Brabant | 3000 | Belgium |
Not provided
| ID | Term |
|---|---|
| D054537 | Atrioventricular Block |
| ID | Term |
|---|---|
| D006327 | Heart Block |
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| D000075224 |
| Cardiac Conduction System Disease |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |