This study aims to evaluate the concurrent validity of a wearable motion sensor (BTS G-sensor) in measuring countermovement jump (CMJ) height. Healthy female volunteers between 18 and 35 years of age will perform CMJ tests. Jump height will be measured simultaneously using the BTS G-sensor and the My Jump smartphone application, which has previously demonstrated validity and reliability. The study will assess the level of agreement between the two measurement methods.
Vertical jump height is widely used as an indicator of lower limb strength and functional performance. Force platforms are the gold standard for jump height measurement but are expensive and not always practical. Wearable motion sensors and smartphone applications have been developed as low-cost and portable alternatives.
This observational study is designed to examine the concurrent validity of the BTS G-sensor, a wearable inertial measurement unit, for measuring countermovement jump (CMJ) height. Measurements obtained from the BTS G-sensor will be compared with those from the My Jump smartphone application, a validated reference tool.
Healthy female volunteers aged 18-35 years will perform countermovement jumps after a standardized warm-up. Each participant's jump height will be simultaneously recorded by both methods. Data will be analyzed using correlation and agreement analyses to determine the level of consistency between the two methods.
This is an observational validation study. Both the BTS G-sensor and the My Jump application were used simultaneously for measurement purposes only. No interventional procedure or assignment was applied to participants.
Clarification on Study Type:
This is an observational validation study. Both the BTS G-sensor and the My Jump smartphone application were used simultaneously for measurement purposes only. No participant assignment or interventional procedure was applied.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Healthy Volunteers | Healthy female participants aged 18-35 years performed countermovement jumps. Jump height was measured simultaneously using the BTS G-sensor and the My Jump application. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| BTS G-sensor | Device | A wearable motion analysis sensor used to assess countermovement jump height. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Jump Height Measured with BTS G-sensor Compared to My Jump Application | Countermovement jump (CMJ) height measured simultaneously with the BTS G-sensor and the My Jump smartphone application. Agreement between the two methods will be analyzed using correlation and Bland-Altman plots. | single testing session, Day 1 |
| Jump Height measured with BTS G-sensor compared to My Jump application | The countermovement jump (CMJ) height will be measured simultaneously using the BTS G-sensor and the My Jump smartphone application. Correlation and agreement between the two methods will be assessed. | single testing session, Day 1 |
Not provided
Not provided
Not provided
Not provided
Healthy female volunteers between the ages of 18 and 35 years were recruited from Ankara Yildirim Beyazıt University. Participants had no recent orthopedic injuries, no neurological conditions, and were not using medications that could affect balance.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Yuksek İhtisas University | Ankara | 06520 | Turkey (Türkiye) |
Not provided
| Label | URL |
|---|---|
| Ankara Yildirim Beyazıt University Faculty of Health Sciences | View source |
Not provided
It is not yet determined whether individual participant data (IPD) will be shared. Decisions will depend on future institutional policies and publication requirements.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| BTS G-sensor | Device | A wearable inertial measurement unit (IMU) used to assess countermovement jump (CMJ) height. |
|