This study aims to compare lung perfusion distribution between inspiratory breath-hold and expiratory breath-hold phases using the saline indicator method combined with electrical impedance tomography (EIT). A self-controlled crossover design will be used in which each participant undergoes both breath-hold conditions with standardized rapid intravenous saline injections. The primary objective is to evaluate changes in global and regional pulmonary perfusion under different lung volume states. The findings may improve understanding of perfusion redistribution with lung inflation and support optimized ventilatory strategies in clinical practice.
Electrical impedance tomography (EIT) with saline bolus injection is a noninvasive technique capable of generating real-time regional lung perfusion images based on transient impedance changes. Lung perfusion is highly dependent on lung volume, vascular resistance, and gravity, yet quantitative bedside evaluation remains limited.
This prospective self-controlled study investigates the differences in lung perfusion between inspiratory breath-hold (near total lung capacity) and expiratory breath-hold (near functional residual capacity). Each participant will undergo two standardized procedures: (1) expiratory breath-hold followed by a rapid intravenous injection of saline, and (2) inspiratory breath-hold followed by the same injection protocol. The order will be randomized.
Perfusion images will be reconstructed using time-impedance curves derived from saline indicator dilution. Regional perfusion parameters, including dependent vs nondependent zones and global perfusion distribution, will be compared between the two phases.
This study may provide foundational physiological evidence for understanding perfusion redistribution across lung volumes and support the clinical application of EIT in respiratory monitoring, ventilatory management, and rehabilitation in critically ill patients.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Single Group - Self-Controlled | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Electrical Impedance Tomography Saline Indicator Procedure | Procedure | Participants undergo continuous electrical impedance tomography (EIT) monitoring with a circumferential electrode belt placed around the thorax. During the procedure, participants perform standardized inspiratory and expiratory breath-hold maneuvers. At each breath-hold phase, a rapid intravenous bolus of sterile saline (10-20 mL) is administered, followed by a saline flush, to generate transient impedance changes for lung perfusion imaging using the saline indicator technique. EIT data are recorded continuously before, during, and after each saline injection. Each participant undergoes both breath-hold conditions and serves as their own control. |
| Measure | Description | Time Frame |
|---|---|---|
| Global Lung Perfusion Distribution | Quantitative assessment of global lung perfusion distribution derived from saline-induced impedance changes measured by electrical impedance tomography during inspiratory and expiratory breath-hold phases. Global perfusion is expressed as the percentage contribution of regional perfusion relative to total lung perfusion. | During the study procedure (within 1 hour) |
| Measure | Description | Time Frame |
|---|---|---|
| Global Lung Perfusion Heterogeneity Index | Spatial heterogeneity of lung perfusion quantified using a perfusion heterogeneity index derived from regional perfusion maps obtained with the electrical impedance tomography saline indicator technique. | During the study procedure (within 1 hour) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Electrical Impedance Tomography Device | Device | An FDA-cleared electrical impedance tomography (EIT) device is used to noninvasively monitor thoracic impedance changes during the study procedures. The device is used solely for physiological monitoring and image acquisition and is not being evaluated for safety, performance, or a new indication. |
|