The GE Healthcare Omni Total Body (TB) 128cms (Omni TB) is a long-axial field-of-view (LAFOV) PET/CT scanner and will be installed in a pre-market phase at the Peter MacCallum Cancer Centre.
The main features and functionality of this new scanner include high sensitivity, high resolution digital detectors based on silicon photomultipliers. The ultra-high sensitivity and extended field of view are designed to support the ability to reduce administrated dose and/or shorten acquisition time without compromising the image quality of the PET imaging.
To verify the appearance of images acquired on the Omni TB with images acquired on our conventional PET/CT equipment, a study imaging a cohort of patients on both devices is proposed. The study involves no additional radiopharmaceutical administration.
Additionally, in keeping with ALARA (as low as reasonably achievable) radiation dose practices, it will be possible to model acquisition settings (duration, administered activity and reconstruction parameters) using the system raw data and a suite of research tools to optimise acquisition parameters.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Imaging on Total Body PET | Experimental | Participants in this arm undergo a total body PET scan after conventional standard-of-care imaging |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PET | Device | This device images the whole body simultaneously with greater sensitivity allowing imaging to occur faster and with less radiation dose compared to conventional PET systems |
| Measure | Description | Time Frame |
|---|---|---|
| To assess the diagnostic quality of images acquired on the OMNI 128 Total Body PET | To analyse the diagnostic image quality visually on the Omni TB with radiotracers F-18 FDG, F-18 DCFPyL, Ga-68 PSMA, Ga-68 DOTATATE or I-124 | 1 Day |
| Measure | Description | Time Frame |
|---|---|---|
| To compare diagnostic image quality on the Omni TB with an existing PET/CT device | Three nuclear medicine specialists will qualitatively assess diagnostic image quality using the the 5-point Likert visual grading score. Reviewers will be blinded to the clinical indication, camera model and reconstruction parameters prior to scoring to remove potential bias by expert reviewers. | 1 Day |
Not provided
Inclusion Criteria:
Exclusion Criteria:
1) Known to be pregnant or breastfeeding
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael Hofman, Prof | Peter MacCallum Cancer Centre, Australia | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Peter MacCallum Cancer Centre | Melbourne | Victoria | 3000 | Australia |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D009369 | Neoplasms |
| D004194 | Disease |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| To compare the sharpness and conspicuity of images produced on the Omni TB with an existing PET/CT device | Three nuclear medicine specialists will qualitatively assess the sharpness and conspicuity of images using the the 5-point Likert visual grading score. Reviewers will be blinded to the clinical indication, camera model and reconstruction parameters prior to scoring to remove potential bias by expert reviewers. | 1 Day |
| To compare the noise characteristics of images acquired using the Omni TB with an existing PET/CT device | Three nuclear medicine specialists will qualitatively assess the noise characteristics of images using the the 5-point Likert visual grading score. Reviewers will be blinded to the clinical indication, camera model and reconstruction parameters prior to scoring to remove potential bias by expert reviewers | 1 Day |
| To compare the quantitative parameters of SUVmean and SUVmax in normal organs on the Omni TB with an existing PET/CT device | One nuclear medicine physician will create a region of interest (ROI) around seven normal tissues (kidneys, liver, spleen, muscle, brain, blood pool, and normal lung) to calculate the SUVmean and SUVmax. This assessment will be conducted on all images acquired to allow a comparison between imaging systems | 1 Day |
| To quantitatively compare the noise characteristics (signal to noise) of images acquired using the Omni TB with an existing PET/CT device | The signal to noise ratio (SNR) will be determined by selecting a volume-of-interest (14cm3) in a region of normal liver. The standard deviation and mean of SUV values within this area will be calculated and used to determine the coefficient of variance (COV) by dividing the SUV standard deviation by the SUVmean. The SNR will then be calculated as the reciprocal of the COV | 1 Day |
| To compare the quantitative parameters of SUVmean, SUVmax and SUVpeak in up to three candidate lesions visualised on the Omni TB and an existing PET/CT device | One nuclear medicine physician will create a spherical 2 cm region of interest (ROI) around up to three candidate lesions to calculate the SUVmean and SUVmax. Target lesion uptake will be determined by placing a 40% isocontour volume of interest (VOI) around the lesion and calculating SUVpeak. This assessment will be conducted on all images acquired to allow a comparison between imaging devices | 1 Day |
| To compare the visibility of lesions in images acquired using the Omni TB with images acquired on an existing PET/CT device | To quantify the contrast between lesions and surrounding normal tissue the tumour to background ratio will be calculated as a function of the lesion SUVpeak over the SUV in the background. These values will be compared across imaging devices | 1 Day |
| To evaluate the quality of images obtained by the Omni TB with reduced scan time | Patients imaged using the Omni TB system will have their images acquired for 10 minutes using LIST mode. This raw list mode data will be retrospectively reconstructed so only data over a specified time frame can be evaluated. Time frames will include, 10, 5, 2 and 1 min. These reconstructions will be analysed according to the secondary outcome measures 2 to 8 | 1 Day |
| To evaluate the quality of images obtained by the Omni TB with reduced injected radioactivity | Patients imaged using the Omni TB system will have their images acquired for 10 minutes using LIST mode. This raw list mode data will be retrospectively reconstructed to match the time per bed step used for the conventional PET/CT device. To simulate a lowered injection dose the LIST mode data will undergo Poisson resampling using the following factors, 1/2, 1/4, 1/8, 1/16 | 1 Day |